G3 Display 006 – 00001GF User’s manual                  

 

 

006-00001DSF rev.002                                                      Clayton Power R&D, s.r.o. 

 

 
 
 

 
 

 

G          13,4V

 50W        3,7A 

 

 

Figure 3: Display main screen description 

3.3

 

Menu 

3.3.1

 

Main menu 

-

 

Boost Charge – During normal charge the Combi charge the battery to 14.4V. When 
boost mode is active, the Combi charges battery to 15.4V. The Boost mode function is 
automatically disabled when the 230vac mains grid is removed, making the Combi return 
to normal charge.  
The function is only used on flooded lead acid cells periodically to desulfate the cells. 
This function should not be used on GEL or AGM batteries. 
 

-

 

Version – shows version of G3 Display firmware and hardware 

3.3.2

 

Genset menu 

The Genset function makes it possible to automatically start a Generator when the battery is 
empty and automatically stops when the battery is full.  
The function requires a Combi in the system to handle the 230vac from the generator.  

 

Figure 4: Menu item tree 

Indication of 
running generator 

Indication of battery 
charging 

230V output power 

Measured battery voltage 

Battery current  
“-“indicate discharging 

Indication of 230VAC 
output is available 

Содержание G3 Display 006-00001GF

Страница 1: ...G3 Display 006 00001GF USER S MANUAL Firmware version 1 02 05 Hardware version 1 03 ...

Страница 2: ...errors which may occur The information may contain errors or inaccuracies and represents no commitment whatsoever Exclusion of liability Clayton Power shall in no event be liable for loss damages or costs arising from use of this Clayton Power product or in any way connected with faulty installation improper operation or incorrect utilization and maintenance Clayton Power shall in no event be liab...

Страница 3: ...of Contents 1 Features 4 2 Installation 4 2 1 Safety instructions 4 2 2 Wiring 4 2 3 Connectors Pinout and Location 4 2 4 Connection to system 5 3 Functions 6 3 1 Keyboard function 6 3 2 Main Screen 6 3 3 Menu 7 3 3 1 Main menu 7 3 3 2 Genset menu 7 4 Label 8 5 G3 Display outline drawing 10 ...

Страница 4: ...ance casualty markings and segregation requirements of the end use application The installation must be performed by professional installer only Switch off the system and check for hazardous voltages before altering any connection Ensure that both units are switched off during the wiring of G3 display to Inverter Charger Combi 2 2 Wiring The maximal length of cables between the G3 display 006 0000...

Страница 5: ...on Output 1 Generator remote control Output 2 Output 3 Hall sensor output Input 1 Input 2 Mating connector type is MOLEX 0039012125 J4 J5 Pin Signal Description 1 2 3 4 5 6 TEMPX1 GND_TELE TEMPX1 SYNC_IN OUT DATA REMOTE OUT N A for Display User s GND Fused N A for Display N A for Display Single Wire Data communication Remote control of G3 Mating connector type is MOLEX 0900750031 Connectors J4 and...

Страница 6: ...arge 3 1 Keyboard function Key Key Function Turn On Display and all connected units Turn Off Display and all connected units Scroll up in the menu list increase set value Scroll down in the menu list decrease set value Enter to the menu if pressed in main screen or escape from menu if pressed in menu Enter to the selected submenu save set value 3 2 Main Screen When menu is not active G3 Display sh...

Страница 7: ... only used on flooded lead acid cells periodically to desulfate the cells This function should not be used on GEL or AGM batteries Version shows version of G3 Display firmware and hardware 3 3 2 Genset menu The Genset function makes it possible to automatically start a Generator when the battery is empty and automatically stops when the battery is full The function requires a Combi in the system t...

Страница 8: ...he generator is allowed to run if the combi is unable to fully charge the battery within this time The timer will start to run when the battery voltage is above the voltage trigger level Manual Cont manual control of generator Generator can be controlled manually from trigger voltage until the battery is detected full While battery voltage is below Voltage trigger level it is not possible to stop ...

Страница 9: ...G3 Display 006 00001GF User s manual 006 00001DSF rev 002 Clayton Power R D s r o 9 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 10: ...G3 Display 006 00001GF 10 Clayton Power R D s r o 006 00001DSF rev 003 5 G3 Display outline drawing ...

Страница 11: ...kia Phone 421 322 85 00 11 CP International Sales Clayton Power GmbH Oberwolfhauserstrasse 10 8633 Wolfhausen Switzerland Phone 41 55 253 26 00 Fax 41 55 253 26 09 Clayton Power and the Clayton Power logo are trademarks of Clayton Power GmbH All other product or service names are the property of their respective owners Clayton Power R D s r o 2009 All rights reserved Document Number 006 00001DSF r...

Отзывы: