9.2 Switching off the Device
The device switches off automatically if no wake-up signal (pin 2) is applied.
9.3 Operating Status
The LEDs indicate the operating status of the device.
LED
Status
Description
Power
Green, steady light
Device active, wake-up signal active
Green, flashing, 1x
Device in standby mode, wake-up
signal active
Charge OUT
Green, steady light
Charging process completed, addi-
tional battery fully charged
Green, flashing (1 Hz) Battery charging, charge status lead
acid battery >80 %, lithium battery
>95%
Green, flashing (4 Hz) Battery charging, charge status: lead
acid battery <80 %, lithium battery
<95%
Charge
IN and OUT
Red, flashing, 1x
Current too high / short circuit.
Device requires restart.
Red, flashing, 2x
Temperature too high. Device auto-
matically restarts.
Red flashing, 3x
Other errors
Jump start
(Emergency start
function)
Green, steady light
Emergency start completed.
Green, flashing (4 Hz) Emergency start active. Starter bat-
tery charging.
Red, flashing
Error, emergency start not possible.
Data
Green, steady light
CAN connection active, device is
controlled.
Green, flashing (1Hz) CAN connection active, device is not
recognised.
IN/OUT 12 V
Green, steady light
12 V charging active
IN/OUT 24 V
Green, steady light
24 V charging active
12
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
9 Normal Operation
LEAB Automotive GmbH