background image

1

INSTRUCTION MANUAL

C61430
C61440
C71320
C71310

PRELI

MINAR

Y

E

N

G

L

IS

H

 

K-EYE K10 HCR - K-EYE K20 HCR

K-EYE S10 HCR - K-EYE S20 HCR

Congratulations on choosing a Claypaky product!

We thank you for your custom.

Please  note  that  this  product,  as  all  the  others  in  the  rich

Claypaky range, has been designed and made with total quality

to  ensure  excellent  performance  and  best  meet  your

expectations and requirements.

INDEX

Page    Contents

2       Safety information

3       Unpacking and preparation

4       Installation and start-up

5       Control panel

9       Maintenance

11      Technical information

Содержание K-EYE K10 HCR

Страница 1: ...hank you for your custom Please note that this product as all the others in the rich Claypaky range has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements INDEX Page Contents 2 Safety information 3 Unpacking and preparation 4 Installation and start up 5 Control panel 9 Maintenance 11 Technical information ...

Страница 2: ...Link auffindbar http www claypaky it en download Ref FIS016 Safety Information A leda K EYE series INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace http www claypaky it en download Ref FIS016 Safety Information A leda K EYE serie...

Страница 3: ...ACKING AND PREPARATION 4 5 4 5 45 4 5 4 5 4 5 45 90 9 0 9 0 9 0 UNLOCKED LOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 2 x 183102 805 1 ...

Страница 4: ...d on the floor resting on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base ...

Страница 5: ...ically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled CONTROL PANEL 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AW...

Страница 6: ...ctivate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations Infor...

Страница 7: ...to be carried out depends on various factors such as the amount of the effects and the quality of the working environment air humidity presence of dust salinity etc It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subjec...

Страница 8: ...3 4 1 2 8 K EYE HCR Battery removal Fig 11 This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 11 ...

Страница 9: ...1 2 3 4 9 K EYE HCR 12 Opening the covers Fig 12 2 1 1 1 1 13 Removing Assembling the lens unit Fig 13 MAINTENANCE Continue ...

Страница 10: ...10 K EYE HCR 10 Replacing the line actuator Fig 14 14 ...

Страница 11: ...echnician Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions ACCESSORIES Two accessories are available for additional control of the beam TOP HAT Motorized Top Hat which is applied to the front lens and pulls out automatically together with the zoom It works as frost gel holder as well C21096 Kit Opzionale Top Hat ...

Страница 12: ...ICATIONS Minimum distance of illuminated objects 0 2 meters 8 Minimum distance from flammable materials 0 2 meters 8 Max ambient temperature 40 C 104 F Max temperature of the external surface 90 C 194 F Safety devices Bipolar circuit breaker with thermal protection Automatic break in power supply in case of overheating Forced ventilation with axial fans RIGGING AND INSTALLATION Working position An...

Страница 13: ...CATIONS Minimum distance of illuminated objects 0 2 meters 8 Minimum distance from flammable materials 0 2 meters 8 Max ambient temperature 40 C 104 F Max temperature of the external surface 90 C 194 F Safety devices Bipolar circuit breaker with thermal protection Automatic break in power supply in case of overheating Forced ventilation with axial fans RIGGING AND INSTALLATION Working position Any...

Страница 14: ......

Страница 15: ......

Страница 16: ...IST011 001 EN PRELIMINARY 06 2017 CLAY PAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it ...