32
SUPERSHARPY
Lower Side
1
2
1
3
2
1
2
1
45°
remove the fan
remove the lamp
contacts protection
unscrew a bit the 4 nuts
to facilitate the lamp
replacement
pay attention to the
right position of the
lamp contacts
(see pictures)
pay attention to the
right position of the
lamp contacts
(see pictures)
Lamp change
- Fig 19.
Take the new lamp out of its package and insert in the fitting.
WARNING:
do not touch the lamp’s envelope with bare hands. Should this happen, clean the bulb with a cloth soaked in alcohol and dry it
with a clean, dry cloth.
Lamp regulation
- Fig. 20
To centre the lamp, turn the adjusting screw as shown in the figure.
WARNING:
The lamp must be adjusted with the projector switched off. After adjusting, close the effects covers, switch on the projector and check
that the adjustment has been correctly made. If necessary, switch off the projector, remove the effects covers and repeat lamp adjustment.
REMARK:
- Lifetime of the lamp will be influenced by the switching cycle.
- After a successful starting, attempt to keep the lamp burning for at least 15 minutes in order to complete the chemical cycle of the
lamp to secure the lifetime.
- Before switch off the fixture, is necessary to keep closed the dimmer channel for at least 5 seconds, this is to ensure a better working
/ reliability of the lamp itself (it is recommended to turn off the lamp when it is dimmed).
WARNING:
• The projector needs to be positioned so that the objects hit by the beam of light are at least 18 metres (59’1”) from the lens of the projector.
A “Soft filter” is available on the Supersharpy (Channel 4 - Colour1 - DMX bit=50) when this ''Soft Filter'' is into the beam, the
projector can be used at a minimum distance of 12 metres from illuminated objects.