A. Static - manual configuration
Manual configuration means that there will be a direct connection to the ISP and all the relevant IP
addresses for the connecting interface are fixed values provided by the ISP which are entered into
CorePlus manually.
Note: The interface DHCP option should be disabled
For static configuration of the Internet connection, the DHCP option must be disabled
(the default) in the properties of the interface that will connect to the ISP.
The initial step is to set up a number of IP address objects in the CorePlus Address Book. Let us
assume for this section that the physical interface used for Internet connection is ge2, the static IP
address for this interface is to be 10.5.4.35, the ISP's gateway IP address is 10.5.4.1, and the network
to which they both belong is 10.5.4.0/24.
Note: Private IP addresses are used for example only
Each installation's IP addresses will be different from these IP addresses but they are
used here only to illustrate how setup is done. Also, these addresses are private IP
addresses and in reality an ISP would use public IP addresses instead.
Let's now add the gateway IP4 Address object which we will call wan_gw and assign it the IP
address 10.5.4.1. The ISP's gateway is the first router hop towards the public Internet from the
Clavister Security Gateway. Go to System > Objects > Address Book in the Web Interface
navigation tree.
The current contents of the address book will be listed and will contain a number of predefined
objects created by CorePlus after it scans the interfaces for the first time. The screenshot below
shows the initial address book for the SG4300 Series.
Note: The all-nets address
The IP address object all-nets is a wildcard address that should never be changed and
can be used in many types of CorePlus rules to refer to any IP address or network
range.
All the interface related address objects are gathered together in an address book folder called
InterfaceAddresses. By clicking on this folder, we open it and can view the addresses it contains.
The first few default addresses in the folder are shown below.
3.3. Manual Web Interface Setup
Chapter 3. CorePlus Configuration
34
Содержание SG4300 Series
Страница 7: ...1 1 Unpacking the Product Chapter 1 Product Overview 7...
Страница 11: ...1 3 The Keypad and Display Chapter 1 Product Overview 11...
Страница 19: ...2 4 Connecting Power Chapter 2 Installation 19...
Страница 58: ...3 6 Going Further with CorePlus Chapter 3 CorePlus Configuration 58...
Страница 62: ...Appendix B Declarations of Conformity 62...
Страница 63: ...Appendix B Declarations of Conformity 63...