1.4. Zero Touch Support
The NetWall 100 Series product is able to support the
Zero Touch
feature in the Clavister
InControl management software product. This means that it is possible to power up a brand new
NetWall 100 Series, connect it to the Internet, and the NetWall 100 Series device will
automatically register itself with an InControl server. The device can then be remotely brought
under centralized InControl management and configured remotely, without any local
configuration needing to be done.
However, this feature will only work if the following prerequisites are true:
•
The version of InControl being used for device management is 2.00.00 or later.
•
The FQDN or IP address of the management InControl server has been set in the
MyClavister
account associated with the NetWall 100 Series device. This is done by logging in to the
relevant
MyClavister
account, selecting
Settings
and then selecting the
Zero Touch
tab. Only
one InControl server address can be associated with one
MyClavister
account.
•
The zero touch feature has been enabled for the license associated with the NetWall 100
Series device. This in the
MyClavister
account by selecting
Licenses
and then enabling the
Zero
Touch
button next to the relevant license. If the zero touch button is grayed out then the
feature is not available with that device. There is an option in the previous step to always
enable zero touch by default for all new licenses.
•
The version of cOS Core running on the NetWall 100 Series must be 12.00.16 or later. This
might require an upgrade of the factory installed cOS Core version.
•
The cOS Core configuration is in its "factory default" state. Following an upgrade to a version
that supports zero touch or any configuration change, this will require a manual reset to the
default cOS Core configuration. In the Web Interface this is done by going to:
Status > Maintenance > Reset & Restart
And then selecting the following option:
Reset the configuration to current core default
Note that a full hardware reset to factory defaults will undo any cOS Core version upgrade
and this should therefore not be done. Also note that any configuration change that is saved
after a reset to the default configuration will disable the zero touch feature.
•
The NetWall 100 Series can be connected to an ISP or other network that can provide Internet
access and that has a DHCP server enabled which can provide a public DNS server address to
the device. Note that physical connection to the Internet should be performed only after the
device is running a zero touch supporting version of cOS Core with the factory default
configuration.
•
Access is not blocked by surrounding network equipment for TCP traffic on port 998. This
traffic is required for the NetWall 100 Series to communicate with the InControl server. DNS
traffic between the NetWall 100 Series and public DNS servers must also not be blocked.
Internet Connection Must Use a Specific Interface for Zero Touch
When the NetWall 100 Series is running a version of cOS Core that supports the zero touch
feature, the initial connection to the Internet for InControl management must be made via the
WAN1 interface for the feature to function.