41000402 Iss 10 

 
 

 

 

 
 

ELECTRICAL CONNECTIONS 

 
Mains power is fed into the remote switch control.  The remote switch control is then connected to the appliance via the 
Terminal Box.  The switch splits the power feed to the appliance allowing ‘fan only – cold blow’ or ‘fan plus heater – hot 
blow’ operation. 
 
Note:  AT ALL TIMES THE APPLIANCE AND REMOTE CONTROL SWITCH MUST BE EARTHED. 
 

Feed mains power ‘L’ and ‘N’ to input side of Left Hand switch. 

 

Connect output side of Left Hand switch ‘L’ to Terminal Box connection ‘H’. 

 

Connect output side of Left Hand switch ‘N’ to Terminal Box connection ‘F’. 

 

making sure this switch output is still cross linked to the input side of the Right Hand switch. 

 

Connect output side of Right Hand switch to Terminal Box connection ‘N’. 

 

OPERATION 

 

Remote Control Switch 

 
 
 
 
 
 
 
 
 
 
 

Left ‘OFF’ / Right ‘OFF’ 

 

 

Appliance ‘OFF’ 

 

Left ‘ON’/ Right ‘OFF 

 

 

Fan only – Cold blow 

 

Left ‘ON’ / Right ‘ON’’ 

 

 

Fan plus heater – Hot blow 

 

Left ‘OFF’ / Right ‘ON’ 

 

 

 

Appliance ‘OFF’

 

Consort Equipment Products Ltd 

Registered Office:  Thornton Industrial Estate 

Milford Haven, Pembrokeshire, SA73 2RT 

Telephone: 01646 692172  Fax: 01646 695195 

 

 

 

INSTALLATION, OPERATION and MAINTENANCE INSTRUCTIONS for

 

 

SURFACE MOUNTED WARM AIR CEILING HEATERS 

 

Catalogue Numbers: 

HE7237 & HE7238

 

 

 

RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE 

 

This  Claudgen  Ceiling  Heater  is  designed  for  suspension  from  a 
ceiling using threaded bar.  It is supplied with stud bar mounting 
kit, painted enclosure and remote mounting control box. 
 

ELECTRICAL CONNECTIONS 
 

The HE7237 has a heating load of 3kW - 230/240V 50Hz 
The HE7238 has a heating load of 3kW - 220V 50Hz 
 
The connections to be made between the heater and the remote 
control box are shown in Fig. 3.  An earth terminal is adjacent to 
the terminal block and is clearly marked with the symbol 

 

 
The unit must be wired in accordance with I.E.E regulations for 
the  Electrical  Equipment  of  Buildings  and  the  installer  should 
ensure that a suitable isolating switch is connected in the mains 
supply. 
 
Fig. 2 shows wiring diagram. 
 

CONTROL 
 

The  remote  control  box  houses  2  double  pole  20  amp  rocker  switches 
and gives the following functions: 

 

SWITCH 1 (LH) 

 

OFF/FAN ONLY 

SWITCH 2 

 

FULL HEAT 

 

MOUNTING 
 

The fan heater box can only be fitted one way round (see Fig.1), 
as  2  of  the  studs  are  offset.    This  ensures  that  the  fan  outlet 
lines  up  with  the  discharge  grille  and  also  that  the  wiring  is 
always sited the same side. 
The  diffuser  is  attached  to  the  discharge  grille  with  4  small 
clips, which can be removed if necessary. 
The discharge grille has 4 additional studs, plus nuts/washer, to 
enable the unit to be chain mounted, if required. 
There  are  also  extra  holes  in  the  box  to  enable  the  unit  to  be 
suspended via wires. 
 

MAINTENANCE 

 

ALWAYS  ENSURE  THAT  THE  MAIN  EXTERNAL  ELECTRICITY  SUPPLY  IS 
SWITCHED OFF BEFORE SERVICING THIS HEATER. 
 

To  obtain  the  best  results  from  the  heater,  it  is  essential  to 
avoid the accumulation of dust and dirt within the unit on the air 
inlet  and  discharge  grilles.    Regular  cleaning  is  necessary  with 
particular  attention  to  the  removal  of  any  dirt  on  the  fan  rotor 
blades.  Cleaning of the fan is best carried out with a soft brush. 
 

PROTECTION (Thermal Cut Out) 

 
The  unit  is  protected  in  the  event  of  fan  failure,  or  an 
obstruction  of  the  free  airflow,  by  a  thermal  PTC  Self  Hold  Cut 
Out.    Having  tripped the PTC Cut Out remains open,  effectively 
switching  off  the  heating  elements,  as  long  as  mains  power  is 
available  inside  the  appliance.    The  PTC Cut Out will only reset 
when  the  appliance  is  switched  OFF  and  allowed  to  cool  for  at 
least 20 minutes. 
 

To reset the PTC Self Hold Cut Out 
 

DO NOT ADJUST BY HAND ANY INTERNAL COMPONENTS 

 

a)

 

The  cutout  is  reset  by  switching  OFF  mains  power  to  the 
appliance. 

b)

 

Allow the appliance to cool for 20 minutes 
Re-start, switch ON the appliance.  If the cutout trips again, 
a qualified electrician should be consulted. 

 

TO REPLACE A FAN/HEATER ASSEMBLY 
 

a)

 

Switch off the mains supply 

b)

 

Release the six nuts and washers fixing the fan heater box to 
the discharge grille 

c)

 

Disconnect  the  fan  heater  wiring  from  the  mains  terminal 
block and earth stud 

d)

 

Remove the fan heater from the box (four screws) 

e)

 

Fit  the  replacement  unit  and  re-assemble  in  the  reverse 
order. 

 

TO REPLACE A SWITCH IN THE CONTROL BOX 
 

a)

 

Switch off the mains supply 

b)

 

Remove the switch box cover 

c)

 

Disconnect the wiring to the switch 

d)

 

Release the spring clips and push out the switch 

e)

 

Fit the replacement switch, reconnect the wiring and replace 
the cover 

 

 