21
If everything seems fine, place the amplifier back into standby and
carefully reconnect the input cable and power the amplifier up. If
the fuse then blows (or the amplifier goes into protection), you
may have a serious fault with your preamplifier/processor. Contact
your authorized Classé dealer.
Finally, if everything is still fine, place the amplifier in standby and
carefully reconnect the speaker wires. Check
both
ends of the
speaker wires for possible short circuits. Then power up the ampli-
fier again. If the amplifier remains functional (the fuse does not
blow), then the original fuse probably blew in order to protect the
amplifier from a large AC mains surge. If it blows again, contact
your dealer for assistance.
12 AC Mains Input
A high-current IEC standard power cord (supplied) is used with
the Omega Mono. Plug the cord into the high-current
IEC re-
ceptacle
provided, and the other end into a suitable wall outlet.
Do not open your amplifier. There are no user-serviceable
parts within this product.
Danger!
Potentially dangerous voltages and current capabilities
exist within your power amplifier, even when it is
disconnected from the AC mains. Do not attempt to
open any portion of the amplifier’s cabinet. There are no
user-serviceable parts inside your power amplifier. All
service of this product must be referred to an authorized
Classé dealer or distributor.