background image

GREAT BRITAIN

 

For consumer contact, please visit www.clasohlson.

co.uk and click on customer service.

ENGLISH

Ver

. 200712

Electronic Transformer 

Article number: 36-2424, model: SET-105M-IM

We apologise for any text or photo errors and any 
changes of technical data.
If you have any questions concerning technical pro-
blems please contact our Customer Service Depart-
ment (see address on reverse.)

Description

This electronic transformer is intended to be used with 
halogen lights and dimmer switches designed for use 
with either mechanical or electronic transformers. 
The transformer starts with reduced current (soft start) 
which gradually increases to full power.
An electronic safety circuit turns the transformer off if 
the secondary coil short-circuits or overheats or if the 
transformer is used without any load. When the fault is 
rectified the transformer starts automatically.

Installation

Please read the entire instruction manual before using 
and save it for future reference.
This product conforms with Directive 89/336/EEC 
regarding Electromagnetic Compatibility and to Low 
Voltage Directive 73/23/EEC.
The product operates on 230 V~. The initial instal-
lation must be carried out by a qualified electrician ac-
cording to VDE standards and the safety regulations 
of the respective country.

Things to consider during installation

The transformer must only be used with halogen 
bulbs, adequate safety measures should be taken 
during installation to avoid electric shock.

The transformer is only intended for indoor 
use. Do not expose the transformer to extreme 
moisture and/or heat (recommended operating 
temperature - 20°C to +45°C)

The transformer has a built-in thermal 
cut-out fuse which operates which 
prevents overheating.

For the primary cable we recommend a 
flat cable with PVC sleeve, conforming 
to VDE 0281, with an area of at least 
0.75 mm².  The secondary cable (to 
the halogen lights) should be 0.75-1.50 
mm².  To avoid RF interference the cables 
connecting to the lights should not be 
longer than 4 metres.

The load on the transformer must not 
exceed or be less than 35 – 105 W.

Connect the lights to the electronic 
transformer as shown in the diagram. 
Primary and secondary cables must not 
cross each other.

The transformer should be placed as close as 
possible to the halogen lights but because the 
lights give off heat, the transformer should be at 
least 30 cm away. The transformer will get hot 
therefore it should be mounted in a well ventilated 
place.

The transformer is double insulated and thus has 
no earth connection, only phase and neutral need 
to be connected.

If the transformer is used in another way than 
described in this manual or is connected 
incorrectly the warranty will not be valid.

Disposal

Follow local ordinances when disposing of this pro-
duct. If you are unsure about how to dispose of this 
product contact your municipality.
      

Specifications

Input Voltage: 

 230-240 V~ +6-10 % 50 Hz

Output Voltage: 

11.6 V~rms

Power Output: 

35-105 W

Power Consumption:  0.46 A
Ambient Temperature ta: Max. 45°C
Housing Temperature tc: Max. 75°C
Primary Cable: 

H03VVH2-F 2x0.75 mm²

Secondary Cable: 

H03VVH2-F 2x0.75-1.50 mm

2

 

 

1 to 2 cables at least 

 

0.3 m long, and max. 4m long, 

 

or 3 cables at least 

 

0.3 m and max. 3 m long, 

 

or 4 to 6 cables at least 

 

0.3 m and max.  2 m long.

Содержание SET-105M-IM

Страница 1: ...xpose the transformer to extreme moisture and or heat recommended operating temperature 20 C to 45 C The transformer has a built in thermal cut out fuse which operates which prevents overheating For the primary cable we recommend a flat cable with PVC sleeve conforming to VDE 0281 with an area of at least 0 75 mm The secondary cable to the halogen lights should be 0 75 1 50 mm To avoid RF interfer...

Страница 2: ...0 C till 45 C Transformatorn har en inbyggd termisk säkring som stänger av vid överhettning För primär kabelanslutning rekommenderas en plattkabel med PVC hölje enligt VDE 0281 med en minsta area av 0 75mm2 Sekundär kabelanslutning till halogenlamporna måste vara 0 75 1 50mm2 För att undvika RF störning får inte anslutningskablarna till lamporna vara längre än 4 meter Belastningen på transformator...

Страница 3: ...eratur 20 C til 45 C Transformatoren har en innebygd termisk sikring som gjør at transformatoren kobler ut ved overoppheting For primær kabeltilkobling anbefales en flatkabel med PVC isolering i følge VDE 0281 med minst 0 75 mm2 lederareal Sekundær kabeltilkobling til halogenlampene må være 0 75 1 5 mm2 For å unngå RF forstyrrelser må ikke tilslutningskablene til lampene være lenger enn 4 meter Be...

Страница 4: ...ilta lämpötiloilta sallittu käyttölämpötilaväli on 20 C 45 C Muuntajassa on sisäinen ylikuumenemissuoja Ensiöpiirin kytkennässä tulee käyttää PVC kuorista lattakaapelia VDE 0281 mukaan jossa on vähintään 0 75 mm2 johdinala Toisiokytkennässä halogeenilampuille tulee käyttää 0 75 1 50 mm2 johdinalan kaapelia Lampuille menevät johdot eivät saa olla yli 4 metriä pitkiä jotta ne eivät aiheuta häiriöitä...

Отзывы: