English
GREAT BRITAIN • CUSTOMER SERVICE
tel: 0845 3009 799
internet:
www.clasohlson.com/uk
V
er
. 20
140
108
Voltage Detector
Art.no 36-2285
Please read the entire instruction manual before use and
save it for future reference. We reserve the right for any
errors in text or images and for making any necessary
technical changes to this document. If you should have
any questions concerning technical problems please
contact our Customer Services.
Warning!
•
Contact with live components can lead to electric
shock with serious consequences.
•
Never use the product if your hands are wet.
•
Never measure voltages of greater than 600 V.
•
Do not use the voltage detector if it is damaged or if
any part of it is missing.
•
Do not dismantle the voltage detector, it contains no
parts that can be altered or repaired.
•
Do not expose the voltage detector to extreme
temperatures or humidity.
Warnings found on the product
Always test the voltage detector on a component known
to be carrying voltage before testing unknown components.
Never use it if you get no indication when testing compo
-
nents known to be carrying voltage!
Description
The voltage detector is intended to indicate when
the test object is live by means of a red LED and buzzer.
•
Contact-free measurement of AC voltage, from 100 V AC
to 600 V AC, 50/60Hz.
•
Robust casing.
•
Suitable for checking the fuses in your distribution
box, indicating cable breaks, live sockets and
insulated cables, e.g. checking which of the Christmas
tree lights has blown etc.
•
Red LED and buzzer to indicate if there is any voltage
in the test object.
•
Built-in LED with on/off switch.
•
Convenient size, equipped with belt clip.
Battery change
1. Carefully bend the attachment clip back until the lock
releases, pull
the battery cover
back (with the LED).
2. Remove the old batteries and insert two new
batteries (LR03) with the plus (+) pointing forward
(as marked on the casing).
3. Push in the attachment clip until it locks in
the normal position.
Use
•
Test the voltage detector on a component that is
known to be carrying voltage.
•
Place the test probes close to the test object
(power point, fuse,etc) draw them along the cable
(if testing the cable).
•
The red LED and weak buzzer tone indicate the
presence of any voltage.
Note!
Draw the test probes along the cable, do not hold
the probes in the same spot, the wires in the cable might
be crossed and the detector measures alternating voltage.
The detector cannot be used on shielded cable, cable in
cable tracks, behind panels or metal surfaces.
Do not rub the test probes on anything before you start
testing, the detector might indicate any static electricity
produced by the rubbing.
Disposal
Follow local ordinances when disposing of this product.
If you are unsure about how to dispose of this product
contact your municipality.
Specifications
Standard
CAT III 1000 V
Measurement Range
100–600 V AC, 50/60 Hz
Operating temperature
-10 to 50 ºC
Humidity
0–30 ºC; 95% RH
30–40 ºC; 75% RH
40–50 ºC; 45% RH
Size
176 mm × Ø 26 mm
Weight
48 g (including batteries)
Batteries
LR03 (×2) (not included)
1. LED
2. Battery cover
3. On/off switch for the LED
4. Attachment clip
5. Detector casing
6. Test probes
1 2 3
4
5
6