Recovery System
49
Service Manual – MA50 15B
Poor pick-up at squeegee
Good water pick up performance depends on the proper amount of air flowing through the squeegee assembly.
Air entering the vacuum system before the squeegee will reduce it’s ability to pick up water. Anything that restricts
the movement of air through the system will also reduce it’s ability to pick up water.
It is also critical to the recovery system that the squeegee blades are in good condition, and have the correct
down pressure. Adjustment of the squeegee down pressure and instructions for replacing the squeegee blades
will be discussed in the squeegee system section.
Removal and Installation
Vacuum motor
Removal:
1.
Drain both tanks completely
2.
Remove the Recovery Tank
3. Disconnect the batteries, and remove as a “pack”
4. Use the Squeegee lift lever on the handle to lower the squeegee assembly
5.
Tip the machine back
6.
Remove the brush/pad driver
7.
Remove the squeegee assembly
8.
Remove the (5) screws that attach the brush deck
(5) Screws
Содержание MA50 15B
Страница 2: ...Clarke MA50 15B 03 2016 Form No 56043172 Service Manual Model Numbers Clarke MA50 15B English...
Страница 14: ...Control System 13 Service Manual MA50 15B Triggers Viewed inside control housing Triggers Trigger switch...
Страница 15: ...Control System 14 Service Manual MA50 15B Solution Control Valve Solution Solenoid...
Страница 21: ...Electrical System 20 Service Manual MA50 15B Wiring Harness Diagram BR 12 17A 17A...
Страница 48: ...Recovery System 47 Service Manual MA50 15B Vacuum Hose Pick Up Tube Adapter Vacuum seals x 2...
Страница 57: ...Scrub System 56 Service Manual MA50 15B Power Switch Brush Switch Switch PCB Behind Label Operating Triggers...
Страница 69: ...Solution System 68 Service Manual MA50 15B Solution Valve Solenoid Solution Switch...
Страница 78: ...Squeegee System 77 Service Manual MA50 15B Squeegee Assembly Squeegee Thumb Screws...
Страница 79: ...Squeegee System 78 Service Manual MA50 15B Squeegee Lift Handle Squeegee Lift Cable...