5
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
ELECTRICAL CONNECTIONS
Connect the mains lead to a suitably fused 400V, 3 phase electrical supply via
a 16 Amp Industrial connector (to BSEN 60309-1/2)
The electric supply connection shall be made by a qualified electrician and
comply with IEC 60364-1.
We strongly recommend that this pressure washer is connected to the supply
via a suitable 3 phase 30 mA Residual Current Device.
FUSE RATING
The fuse rating for this pressure washer is 16 Amps.
EXTENSION CABLES
If an extension cable is used, always ensure it is fully unwound. When used
outdoors, ensure the extension cable is specifically designed for outdoor use.
If an extension cable is used, the plug and socket must be of watertight
construction.
WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE
MAINS SUPPLY.
WARNING: INADEQUATE EXTENSION CABLES CAN BE DANGEROUS.
ENSURE THE CABLE IS RATED FOR THE VOLTAGE AND AMPERAGE OF THE
PRESSURE WASHER.
HLS160 3 Phase hot wash.fm Page 5 Wednesday, September 28, 2011 12:28 PM
Содержание HLS160
Страница 24: ......