6
BLEEDING AIR FROM THE SYSTEM
1. Use the operating lever to turn the release valve anti-clockwise, relieving
pressure inside the jack.
2. Pump the operating lever several times to purge air from the system.
3. Turn the release valve clockwise and test the jack. If efficiency is still low,
check the oil level as described.
4. Wipe up any oil spillage and dispose of old/spilled oil appropriately.
TROUBLESHOOTING
If any of these remedies fail to restore your jack, consult your Clarke dealer.
SPARE PARTS
The Operating Lever, Rubber Puck, Rear Castor assembly are available as user
serviceable parts from your Clarke dealer, or Clarke International Parts
Department.
PROBLEM
CAUSE
SOLUTION
Jack will not lift the
rated load
Low oil level
Check for leakage and top up
if required.
Release valve not
closed
Turn release knob fully
clockwise.
Air in the hydraulic ram
Purge of air as on page 4.
Jack lowers when
under load
Release valve not fully
closed
Turn the release knob fully
clockwise.
Air in the hydraulic ram
Purge of air as on page 4.
Pump feels spongy
Low oil level
Check for leakage and top up
if required.
Air in the system
Purge of air as on page 4.
Handle raises or flies
back under load
Air in the hydraulic ram
Purge of air as on page 4.
Jack will not lift full
height
Low oil level
Check for leakage and top up
if required.
Air in the hydraulic ram
Purge of air as on page 4.
Jack will not lower
completely
Return spring may be
faulty.
Return to your Clarke dealer for
repair.