background image

10

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

CHECK THE ENGINE OIL LEVEL

NOTE: 

Place the generator on a level surface and check the oil level as 

follows.

1. Remove the maintenance panel 

shown on the right.

2. Turn the oil filler cap anti-

clockwise and remove from the oil 
reservoir, wipe the dipstick with a 
clean cloth.

3. Insert the dipstick back into the oil 

filler tube and then remove it 
again. 

4.

Max Level

Min. Level

If the oil is below the Min. level on 
the dipstick, Fill the oil reservoir 
with fresh oil.

• Do not fill above the max level 

mark (0.45 litres)

• We recommend the use of 

SAE15W-40 oil in this generator.

• Do not tilt the generator when 

adding engine oil. This could 
result in overfilling and damage 
to the engine.

5. Replace the oil filler cap.

6. Replace the left side maintenance panel.

WARNING: YOUR GENERATOR MAY NOT BE SUPPLIED WITH OIL, ALWAYS 
ENSURE THAT THERE IS SUFFICIENT OIL BEFORE USE.

WARNING: TO CARRY OUT THIS CHECK, THE ENGINE MUST BE OFF. 

Содержание 8877120

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0919 ISS 1 2 2KW INVERTER GENERATOR MODEL NO IG2200A PART NO 8877120 ...

Страница 2: ...f of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Through purchase of this product ...

Страница 3: ...ERVIEW 7 UNPACKING AND ASSEMBLY 8 BEFORE USING THE GENERATOR 8 Earth point 8 Checking the air filter 9 Check the engine oil level 10 Check the fuel level 11 USING YOUR GENERATOR 12 Starting the engine 12 Connecting electrical devices 14 Economy switch 16 Indicator lights 16 Shutting down the generator 17 MAINTENANCE 18 Engine oil every 20 hours of use 18 Air filter every 50 hours of use 19 Spark p...

Страница 4: ...uildings or other equipment or the engine may overheat 2 Place the generator on a solid flat surface 3 Make sure the surrounding area is free from any material that could burn or be damaged by heat 4 Never move or tilt the generator whilst it is switched on FIRE PREVENTION 1 Always switch the engine OFF when refuelling 2 Always refuel in a well ventilated area 3 Never overfill the tank fill to the...

Страница 5: ...er or any other liquids to clean the generator 4 Make sure you ground earth the generator ADDITIONAL SAFETY RULES FOR GENERATORS 1 Always make sure the applied load does not exceed the generator rating Overloading the generator is dangerous and could cause serious damage 2 Always disconnect the generator when carrying out any maintenance 3 Always allow the generator to reach operating speed before...

Страница 6: ...nal com or Service clarkeinternational com SAFETY SYMBOLS Caution The user should be aware of a general hazard Dangerous Voltage Flammable Hot Surface Do not touch Poisonous fumes Do not use the generator in an enclosed space Read Instruction manual before use ...

Страница 7: ...ESCRIPTION 1 Air Vent Knob 10 Earthing Point 2 Fuel Cap 11 Economy Control Switch 3 Fuel Valve Knob 12 AC Sockets 4 Starting Handle 13 DC Socket 5 Left Side Maintenance Cover 14 DC Circuit Breaker 6 Top Maintenance Cover 15 Overload Indicator 7 Muffler 16 Output Indicator 8 Choke 17 Oil Alarm Indicator 9 Engine ON OFF Switch 18 Primer Bulb ...

Страница 8: ... Connector Lead 1 x Oil Drain Tube BEFORE USING THE GENERATOR IMPORTANT Generators should ALWAYS be earthed Make sure you ground earth the generator Before using your generator check that The generator is in good condition and free from any damage The generator is clean and free from fuel or oil spillage The generator is correctly located for use See page 4 There is no leakage NOTE To avoid accide...

Страница 9: ...lter is damaged contact CLARKE spare parts department for a replacement If the filter is dirty wash it in a solution of warm water and mild detergent and rinse thoroughly Leave the filter to dry completely once it is dry immerse the filter in clean engine oil and sqeeze the filter to remove excess oil 6 Replace the filter into its original position and replace and secure the air filter cover then ...

Страница 10: ...to the oil filler tube and then remove it again 4 Max Level Min Level If the oil is below the Min level on the dipstick Fill the oil reservoir with fresh oil Do not fill above the max level mark 0 45 litres We recommend the use of SAE15W 40 oil in this generator Do not tilt the generator when adding engine oil This could result in overfilling and damage to the engine 5 Replace the oil filler cap 6...

Страница 11: ...eaded petrol with a octane number of 86 or higher WARNING MAKE SURE THERE IS FUEL IN THE TANK WHEN USING THE GENERATOR RUNNING OUT OF FUEL OR STOPPING THE ENGINE SUDDENLY WITH A LOAD CONNECTED COULD CAUSE SERIOUS DAMAGE WARNING FUEL IS HIGHLY FLAMMABLE AND POISONOUS WARNING SEE GENERAL SAFETY RULES ON PAGE 4 AND READ THEM CAREFULLY BEFORE REFUELING WARNING DO NOT FILL ABOVE THE TOP OF THE FUEL FIL...

Страница 12: ...NG YOUR GENERATOR STARTING THE ENGINE 1 Remove all connections from the AC sockets 2 Air vent knob Hold the fuel tank cap so that it will not move and turn the air vent knob to the ON position 3 Turn fuel valve to the ON position pointing downwards 4 Set the engine switch to ON 5 Move the choke to the left ...

Страница 13: ...nd pull the starting handle lightly until you start to feel resistance and then pull up sharply to start the engine NOTE You may have to do this more than once NOTE When you first start the generator the overload indicator may light up for a few seconds this is normal If the overload indicator is still lit after 5 seconds stop the engine and contact your CLARKE dealer 8 Once the engine has warmed ...

Страница 14: ...ned off before connecting it to the generator 3 Connect the appliance to the generator CAUTION MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER IF IT BEGINS TO ACT ABNORMALLY OR STOPS SUDDENLY DISCONNECT IT FROM THE GENERATOR CAUTION MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM RATED LOAD FOR THE GENERATOR CAUTION ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E G DEVICES ...

Страница 15: ...o the negative terminal of the battery 4 Connect the battery charging leads to the generator The battery will begin to charge 5 Monitor the voltage across the battery regularly during charging and disconnect the battery when the voltage reaches 14 4 volts CAUTION WHEN DISCONNECTING THE BATTERY ALWAYS DISCONNECT THE NEGATIVE LEAD FIRST DC OVER LOAD PROTECTOR If the DC overload protector activates w...

Страница 16: ...will light up if there is an overload or a short circuit in the connected appliance If this happens proceed as follows 1 Turn off any connected electrical devices and stop the engine 2 Reduce the total wattage of connected electric devices to within the rated output of the generator 3 Check air inlet and around the control unit If any blockages are found remove them 4 After checking restart the en...

Страница 17: ...e generator in an emergency simply set the engine switch to OFF NOTE Turn off any electric devices NOTE Set the economy control switch to the 0 OFF position 1 Disconnect any electric devices 2 Turn the fuel valve knob to OFF pointing left 3 Air vent knob Turn the air vent knob to the off position 4 Set the engine switch to the 0 OFF position ...

Страница 18: ...s shown 4 Tilt the generator to allow the oil to drain out of the oil reservoir into a suitable container NOTE You may need assistance with this step as the generator is heavy 5 Max Level Min Level Fill the oil reservoir with fresh oil Do not fill above the max level mark 0 45 litres We recommend the use of SAE15W 40 oil in this generator 6 Replace the oil filler cap and maintenance panel CAUTION ...

Страница 19: ...ent 5 If the air filter is damaged contact CLARKE spare parts department for a replacement If the filter is dirty wash it in a solution of warm water and mild detergent and then rinse thoroughly Leave the filter to dry completely once it is dry immerse the filter in clean engine oil and sqeeze the filter to remove excess oil 6 Replace the filter into its original position and replace and secure th...

Страница 20: ...USE 1 Remove the top maintenance panel 2 Remove the spark plug cap from the spark plug 3 Assemble the spark plug spanner as shown 4 Use the spark plug spanner supplied to remove the spark plug 5 Check for discoloration and use a wire brush to remove any carbon build up CAUTION ALLOW THE ENGINE TO COOL BEFORE REMOVING THE SPARK PLUG ...

Страница 21: ... if damaged NOTE Spark plugs are available from CLARKE Spare Parts department 020 8988 7400 8 Reinstall the spark plug and replace the spark plug cap FUEL TANK FILTER Just inside the fuel tank is a fuel filter check this filter periodically and remove any contaminants which may have accumulated 1 Fuel filler cap Remove the fuel tank cap 2 Lift out the filter inside 3 Fuel filter Clean the filter w...

Страница 22: ... plug See page 20 The generator fails to generate electricity The device you are trying to power is faulty Make sure the device you want to power is working properly The overload indicator is on Remove the appliance immediately do not connect any appliance that requires more than 2 2 KVA DC supply only The DC Overload protector has activated Press the reset button See page 15 The generator is diff...

Страница 23: ...oline OHV Displacement cm 3 125 Ignition type T D I Fuel tank capacity L 6 1 Maximum run time at 3 4 load h 7 Engine oil capacity L 0 45 Guaranteed sound power LWA dB 92dB GENERATOR Rated Frequency Hz 50 Rated AC Voltage V 230 Rated Power kW 2 Maximum Power kW 2 2 DC Output Voltage V 12 DC Output Current A 8 3 DIMENSIONS Length mm 542 Width mm 288 Height mm 486 Unpacked Weight kg 26 6 ...

Страница 24: ...24 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 25: ...25 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 26: ...26 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com NOTES ...

Страница 27: ...27 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com NOTES ...

Страница 28: ......

Отзывы: