background image

OPERATION & MAINTENANCE

INSTRUCTIONS

LS0716

2.2 KVA PETROL GENERATOR

MODEL NO: PG2500A

PART NO: 8857850

Содержание 8857850

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0716 2 2 KVA PETROL GENERATOR MODEL NO PG2500A PART NO 8857850 ...

Страница 2: ...f of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Through purchase of this product ...

Страница 3: ...re the generator is on a solid flat surface 3 Always ensure the surrounding area is free from any material that could burn or be damaged by heat 4 Never move or tilt the generator whilst it is switched on FIRE PREVENTION 1 Always switch the engine OFF when refuelling 2 Always refuel away from any source of heat 3 Always refuel in a well ventilated area 4 Only use standard unleaded petrol 5 Never s...

Страница 4: ...DDITIONAL SAFETY RULES FOR GENERATORS 1 Always ensure the applied load does not exceed the generator rating Overloading the generator is dangerous and could cause serious damage 2 Always disconnect the generator when carrying out any maintenance 3 Always ensure the generator reaches operating speed before connecting a load 4 Never allow the generator to run out of fuel when a load is connected 5 N...

Страница 5: ...nal com or Service clarkeinternational com SAFETY SYMBOLS Read Instruction manual before use Flammable Caution The user should be aware of a general hazard Hot Surface Do not touch Dangerous voltage Poisonous fumes Do not use the generator in an enclosed space ...

Страница 6: ...arkeinternational com GENERATOR OVERVIEW NO DESCRIPTION NO DESCRIPTION 1 Fuel Supply Valve 7 Engine Switch 2 Fuel Tank Cap 8 Anti vibration Feet 3 Fuel Level Gauge 9 Oil Dipstick 4 Frame 10 Control Panel 5 Air Filter 11 Choke Lever 6 Starting Handle recoil pull start 12 Earth Point ...

Страница 7: ...re using your generator check that The generator is in good condition and free from any damage The generator is clean and free from fuel or oil spillage The generator is correctly located for use See page 3 The fuel system is intact and there is no leakage NOTE Always use a funnel to fill the fuel tank to avoid accidental spillage of fuel If fuel is spilled it must be cleaned up before use The gen...

Страница 8: ...ck back into the oil fill tube and then remove it again Do not screw in the oil filler cap dipstick when doing this 4 If the oil level is at or below the L mark on the dipstick add oil to the crankcase Fill until the oil reaches the threads in the oil fill tube Oil capacity See page 20 We recommend the use of SAE15W 40 oil in this generator available from your CLARKE dealer 5 Replace the oil fille...

Страница 9: ... filler cap 3 Fuel filter Just inside the fuel tank is a fuel filter which catches any contaminants as you refuel 4 Slowly add fuel to the fuel tank maximum 15L watching the fuel level gauge as you do so RECOMMENDED FUEL Only use standard unleaded petrol NOTE Do not overfill the fuel tank 5 Replace the fuel filler cap securely WARNING ALWAYS REFUEL IN A WELL VENTILATED AREA AWAY FROM ANY HEAT SOUR...

Страница 10: ...ternational com USING YOUR GENERATOR STARTING THE ENGINE 1 Remove all connections from the AC sockets 2 Set the fuel valve to the ON position as shown 3 Make sure that the AC breaker is set to the off down position 4 Move the choke lever to the Choke position 5 Set the engine switch to ON ...

Страница 11: ... NOTE You may have to do this more than once NOTE When you first start the generator the overload indicator may light up for a few seconds this is normal If the overload indicator is still lit after 5 seconds stop the engine and contact your CLARKE dealer 7 Once the engine has warmed up move the choke lever to the run position 8 WARNING ONCE THE GENERATOR HAS STARTED RELEASE THE STARTING HANDLE SL...

Страница 12: ...reaker will activate if the generator is overloaded If the AC Breaker activates 1 Remove any connected devices from the generator 2 Wait for a few minutes 3 Set the AC breaker to the ON up position 4 Reconnect the devices to the generator making sure your do not exceed the maximum capacity of the generator CAUTION MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER IF IT BEGINS T...

Страница 13: ...t the battery charging leads to the generator The battery will begin to charge 4 Monitor the voltage across the battery regularly during charging and disconnect the battery when the voltage reaches 14 4 volts Do not allow the clamps to touch each other whilst connected to the generator DC OVERLOAD PROTECTOR If the DC overload protector activates wait for a few minutes and then press the reset butt...

Страница 14: ...UTTING DOWN THE GENERATOR To stop the generator in an emergency simply set the engine switch to OFF 1 Turn off and disconnect any electric devices 2 Make sure that the AC breaker is set to the off down position 3 Set the engine switch to the 0 OFF position 4 Set the fuel valve to the OFF position as shown ...

Страница 15: ...s out faster 4 Replace the drain plug 5 Fill the crankcase with engine oil Fill until the oil reaches the threads in the oil fill tube Oil capacity See page 20 We recommend the use of SAE15W 40 oil in this generator available from your CLARKE dealer 6 Replace the dipstick ENVIRONMENTAL PROTECTION One of the most damaging sources of pollution is oil Do not throw away used engine oil in with your do...

Страница 16: ...spanner supplied to remove the spark plug 3 Remove any carbon that has accumulated around the electrode 4 Check the spark plug gap a it should be between 0 7 and 0 8 mm adjust if necessary 5 Check the overall condition of the spark plug for erosion or pitting and replace if necessary 6 Reinstall the spark plug and replace the spark plug cap CAUTION ALLOW THE ENGINE TO COOL BEFORE REMOVING THE SPAR...

Страница 17: ...ARKE spare parts department for a replacement If the filter is dirty wash in a solution of warm water and mild detergent and rinse thoroughly Leave the filter to dry completely once it is dry immerse in clean engine oil and squeeze to remove excess oil 4 Replace the filter to its original position and replace the air filter cover CAUTION DO NOT USE THE GENERATOR WITHOUT THE AIR FILTER FITTED THIS ...

Страница 18: ...LTER O RING CUP nscrew and remove the cup then remove the valve filter and O ring 3 Wash these parts in a non inflammable solvent Make sure that the valve filter is not damaged 4 Place an approved petrol storage container under the fuel valve and set the fuel supply valve to ON The fuel in the tank will drain into the container 5 Replace the O ring and valve filter and tighten the cup as far as po...

Страница 19: ...e 9 Spark plug not working correctly Change the spark plug See page 16 The generator fails to generate elec tricity The device you are trying to power is faulty Make sure the device you want to power is working properly The AC breaker is switched off Switch the AC breaker on The generator is difficult to start The air filter is dirty Clean the air filter See page 17 The fuel filter is blocked Clea...

Страница 20: ...ut hp rpm 5 6 3000 rpm Start system Hand recoil Fuel tank capacity L 15 Fuel consumption L hr 1 6 Maximum run time h 75 Load 10 6 Engine oil type SAE15W 40 Engine oil capacity L 0 6 Guaranteed sound power LWA dB 94 Generator Rated Frequency Hz 50 AC Output Voltage V 230V 13A DC Output Voltage V 12V Max 8 3A Maximum Rated Power W 2200 Dimensions Length mm 595 Width mm 430 Height mm 430 Unpacked Wei...

Страница 21: ...21 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM ...

Страница 22: ...24 Fuel Valve 7 Earth Bolt 25 Frame 8 DC Socket 26 Cross Beam 9 DC Breaker 27 Anti Vibration Foot LH 10 Panel Back Cover 28 Flange Nut M8 11 Wiring Loom 29 Rubber Feet 12 Bolt M6x12 30 Anti Vibration Foot RH 13 Bridge Pile 31 Back Guard Plate 14 Engine 32 Flange Bolt M6x12 15 Generator 33 Side Guard Plate 16 Fuel Tank 34 Flange Bolt M6x12 17 Rubber Gasket 35 Flange Bolt M6x35 18 Washer 36 Upper Gu...

Страница 23: ...23 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 24: ......