background image

OPERATION & MAINTENANCE

INSTRUCTIONS

GC1220 - ISS 3

ORIGINAL INSTRUCTIONS

SUBMERSIBLE DIRTY WATER PUMP

MODEL NO: DWP100A, DWP150A, DWP200A

PART NO: 7230098, 7230099, 7230100

Содержание 7230098

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC1220 ISS 3 ORIGINAL INSTRUCTIONS SUBMERSIBLE DIRTY WATER PUMP MODEL NO DWP100A DWP150A DWP200A PART NO 7230098 7230099 7230100 ...

Страница 2: ...hich will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Thro...

Страница 3: ... and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump explosive flammable liquids or chemicals 2 Never allow the pump to run dry or operate out of the water 3 Submersible pumps should always be submerged and stored vertically 4 Disconnect the pump from the mains...

Страница 4: ...onal com or Service clarkeinternational com PART IDENTIFICATION Remove all packaging and make sure that the unit shows no visible damage Dispose of all packaging appropriately 1 WATER INLET 4 WATER OUTLET 2 FLOAT SWITCH 5 HANDLE 3 PLUG AND CABLE 6 CABLE CLAMP ...

Страница 5: ... which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green An approved Residual Current Device RCD which has a tripping current of less than 30mA must be used If you are not sure consult a qualified electrician DO NOT try to do any repairs OVERLOAD SWITCH These pumps are fitted with a thermal overload switch If the pump ove...

Страница 6: ... using a rope attached to the lifting handle Take all necessary precautions as described on page 3 The pump inlet must be fully submerged before the pump is switched on 3 Connect the mains plug to a high sensitivity residual current device RCD which has a tripping current of less then 30mA 4 Switch the mains power supply on The pump will begin to drain water As the water level falls so will the fl...

Страница 7: ...er debris 2 Take extra care to remove any debris from around the impeller NOTE Do not attempt to repair the pump yourself Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department STORAGE When the pump is not being used for extended periods clean and dry it thoroughly and store it indoors If the pump is left in water it must be run at least once a week to prevent i...

Страница 8: ... OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the discharge tube is not clogged or obstructed 3 The head may be too great i e you are trying to lift the water too great a distance for the pump to cope with Specifications on page 7 4 Air bubble in the p...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 10: ... Spring Washer 39 Bolt 6 Spring Washer 23 Bolt 40 Handle 7 Washer 24 O Ring 41 Oil Plug Screw 8 Impeller 25 Rotor 42 O Ring 9 Casing 26 Bearing 43 Screw 10 Bolt 27 Insulation Paper 44 Spring Washer 11 Outer Connector 28 Bottom Bearing Chuck 45 Capacitor Seal Cover 12 Sealing Flange 29 Mechanical Seal 46 Capacitor 13 Spring Washer 30 Control Set 47 Corrugated Sheet 14 Nut 31 Lip Seal 48 Stator 15 S...

Страница 11: ...ONS DWP100A DWP150A DWP200A Voltage 230V 50Hz 230V 50Hz 230V 50Hz Outlet Diameter 2 BSP inc 2 1 Hose Adaptor 2 BSP inc 2 1 5 HoseAdaptor 2 BSP inc 2 Hose Adaptor Power 740 W 1100 W 1500 W Maximum Head Height 10 m 12 m 10 m Maximum Output 200 l min 250 L min 600 L min Maximum Depth 5 m 5 m 5 m Max Water Temperature 40oC 40oC 40oC Maximum Particle Size 6 8 mm 6 8 mm 7 mm Weight 13 5 kg 15 kg 21 kg D...

Страница 12: ......

Отзывы: