Clarke 3120110 Скачать руководство пользователя страница 1

OPERATING & MAINTENANCE

INSTRUCTIONS

ORIGINAL INSTRUCTIONS                                                   GC0220 rev 1

RATCHET WRENCH

MODEL NO: CAT108 & CAT109

PART NO: 3120110 & 3120116

Содержание 3120110

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0220 rev 1 RATCHET WRENCH MODEL NO CAT108 CAT109 PART NO 3120110 3120116 ...

Страница 2: ...rward to your purchase giving you long and satisfactory service Please keep these instructions in a safe place for future reference SPECIFICATION Model Number CAT108 CAT109 Part Number 3120110 3120116 Drive Type 1 2 Square 3 8 Square Max Torque 50 ft lb 68 Nm 50 ft lb 68 Nm Dimensions L x W x H 265 x 48 x 42 mm 265 x 48 x 42 mm Weight 1 2 kg 1 2 kg Max Operating Pressure 90 psi 6 2 bar 90 psi 6 2 ...

Страница 3: ...ess appropriately Do not wear loose clothing or jewellery Tie long hair out of the way 3 Keep children and visitors away Do not let children handle the tool 4 DO NOT operate the tool where there are flammable liquids or gases USE OF AIR POWERED TOOLS 1 Stay alert and use common sense do not operate the tool when you are tired or under the influence of alcohol drugs or medication 2 ALWAYS wear eye ...

Страница 4: ...operating abnormally 14 This tool should be serviced at regular intervals by qualified service personnel 15 Avoid damaging the tool for example by applying excessive force of any kind 16 ALWAYS maintain the tool with care Keep it clean for the best and safest performance 17 Quick change couplings should not be located at the tool They add weight and could fail due to vibration 18 DO NOT force or m...

Страница 5: ... is used it will keep air tools in good condition but should be regularly checked and topped up with oil CLARKE airline oil should be used and the lubricator be adjusted to approx 2 drops per minute Use only clean dry regulated compressed air as a power source WARNING COMPRESSED AIR CAN BE DANGEROUS ENSURE THAT YOU ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF COMPRESSORS AND A COMPRESS...

Страница 6: ...essure for the air tool It is recommended that air pressure to this tool does not exceed 90 psi at the air tool when running Higher pressures and dirty air will shorten the life of the tool due to faster wear and is a possible safety hazard Check hoses for wear or damage before use USEFUL ACCESSORIES A wide range of accessories are available including filter regulators lubricators high pressure ho...

Страница 7: ... International Service Department for further information CLARKE Air Line Oil part no 3050825 is available from your CLARKE dealer PRODUCT OVERVIEW The pack should include the following items Reversible ratchet Male Snap Connector Bottle of Airline Oil 1 Forward Reverse Switch 3 Trigger 2 1 4 Square Drive Shaft 4 Air Inlet 5 Airline connector ...

Страница 8: ...ps of oil through the tool before use It can be entered through the airline connector or via the hose at the nearest connection to the air supply 6 Connect the other end of the hose to the compressor 7 Turn on the air supply and check for air leaks Rectify any found before proceeding Set the working pressure to 90psi 6 2 bar for best performance PTFE tape may be useful for sealing threaded connect...

Страница 9: ...e and push it onto the square drive shaft It clicks into place when secure 2 Place the socket over the nut Take care that the socket is firmly engaged 3 Squeeze the trigger against the body of the tool to start 4 Release the trigger to stop the tool 5 ALWAYS ensure the tool has stopped before putting it down 6 When releasing very tight fastenings initially break loose by hand Squeeze the trigger a...

Страница 10: ...sconnect the air supply hose from the air tool 3 Shut down the compressor at the end of the work session and drain daily as recommended STORAGE When not in use disconnect from the air supply clean store in a safe dry place If the tool is to be stored or is idle for longer than 24 hours run a few drops of CLARKE air line oil into the air inlet and run the tool for 5 seconds in order to lubricate th...

Страница 11: ...EANING 1 Grit or gum deposits in the tool may reduce efficiency 2 After extensive use remove the inlet screen filter and flush out the mechanism with gum solvent oil or an equal mixture of CLARKE air line oil and paraffin Allow to dry before use 3 If the tool still runs erratically or becomes inefficient and the air supply is of good quality it may be necessary to dismantle the air motor and repla...

Страница 12: ...ore using Tool runs slowly Air flows weakly from exhaust 1 Motor parts jammed with gum dirt 2 Air line regulator in closed position 3 General airflow blocked by dirt 1 Examine inlet air filter for blockage and clean it if necessary Drip a few drops of air tool lubricat ing oil into air inlet 2 Adjust in line regulator to open position 3 Operate tool in short bursts Tool will not run Air flows free...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS DIAGRAM ...

Страница 15: ... bearing 5 Valve stem 26 Bearing shell 6 Air inlet plug 27 Crankshaft 7 Pin 28 Drive bush 8 Trigger 29 Ratchet yoke 9 Housing 30 Spring 10 Rear bearing 31 Locking pin 11 Rear plate 32 Reverse switch 12 Rotor blade 33 Washer 13 Rotor 34 Pin 14 Pin 35 Ratchet pawl 15 Cylinder 36 Ratchet anvil 16 Front plate 37 Steel ball 17 Bearing 38 Spring 18 Washer 39 Spring 19 Gear housing 40 Steel ball 20 Idler...

Страница 16: ......

Отзывы: