background image

OPERATION & MAINTENANCE

INSTRUCTIONS

LS0715

VERTICAL AIR COMPRESSORS

MODEL NO: VE15C150, VE18C150, VE25C150

PART NO: 2226010, 2226020, 2226025

Содержание 2226010

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0715 VERTICAL AIR COMPRESSORS MODEL NO VE15C150 VE18C150 VE25C150 PART NO 2226010 2226020 2226025...

Страница 2: ...tee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase...

Страница 3: ...to the recommended setting for the tool 10 When spraying flammable materials e g cellulose paint ensure that there is sufficient airflow and keep clear of any source of ignition 11 Before spraying an...

Страница 4: ...amp environment Risk of accidental start up The compressor could start automatically in the event of a power cut and subsequent reset Do not carry the compressor while it is connected to the power sou...

Страница 5: ...utral terminal Connect the remaining wires to the termainals marked L1 L2 and L3 Due to these high currents the product must only be connected to a 3 phase supply capable of supporting these loads plu...

Страница 6: ...hown on the data label Make sure that the compressor is on firm level ground This compressor must be secured to the ground through the feet using suitable bolts and washers CHECK THE OIL LEVEL 1 Remov...

Страница 7: ...ompressor Do not lift by or put strain on valves or hoses CONNECTING AIR TOOLS 1 Attach the air hose to the outlet valve 2 Attach the air tool to the other end of the air hose 3 Turn the outlet valve...

Страница 8: ...ed It will then shut down The compressor will start up again when the pressure in the reservoir decreases CHECK THE SAFETY VALVE To make sure that the safety valve works correctly 1 Pull on the ring a...

Страница 9: ...e the air hose 4 Disconnect the tool from the hose TURNING THE COMPRESSOR OFF 1 Follow steps 1 4 in Removing Tools From The Air Hose above 2 Disconnect the compressor from the power supply 3 Slowly op...

Страница 10: ...power supply 2 Put a container below the drain valve to collect the condensate The drain valve is located on the bottom of the reservoir 3 Open the drain valve slowly Condensation will drain from the...

Страница 11: ...ER MONTHLY The air filter must be examined monthly more often in dusty conditions 1 Remove the securing bolt and pull the filter housing from the compressor 2 Unclip the front and rear of the filter a...

Страница 12: ...of operation or every 6 months To empty the oil from the machine remove the oil drain plug from the crankcase CHECK THE NON RETURN VALVE EVERY 6 MONTHS If the reservoir pressure decreases for no appa...

Страница 13: ...rive belt over the small wheel 4 Position part of the drive belt over the large belt wheel as shown 5 Rotate the large belt wheel by hand in a clockwise direction whilst guiding the belt on to it Take...

Страница 14: ...0 VE25C150 Part Number 2226010 2226020 2226025 Max Pressure 10 bar 10 bar 10 bar Voltage 3 Phase 400V AC 50 Hz 3 Phase 400V AC 50 Hz 3 Phase 400V AC 50 Hz Air Displacement 14 cfm 18 cfm 23 cfm Receive...

Страница 15: ...ch the set pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest service agent Compressor does not start The reservoir has already fully press...

Страница 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 17: ...17 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com ALSO AVAILABLE FROM CLARKE...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com NOTES...

Страница 20: ......

Отзывы: