18
menu #2 - advanced features
2-1 SIREN/HORN HONK:
The system can be programmed to output pulses instead of a continuous out-
put when the system is triggered. This is useful to honk the factory horn in applications where a siren
is undesirable. Remember that the unit is only capable of supplying 1 amp of current. A relay will be
required to interface with most factory horn systems.
2-2 SIREN DURATION 30/60 SECONDS:
It is possible to program the unit to sound for 30 or
60 seconds during the triggered sequence. Some states have laws regulating how long a secu-
rity system can sound. When using the Pro Security Programmer, the siren can be programmed
to sound for any length of time ranging from 1 to 180 seconds. Using the SELECT button of the Pro
Security Programmer will adjust the siren duration in one second increments.
2-3 FALSE ALARM PREVENTION CIRCUITRY ON/OFF:
Stops repeated triggering of the same zone. If
one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time
of the third trigger. During that hour, if the system detects a trigger on that zone again, the system resets
the one hour timer. If one hour passes and the zone has not triggered again, the zone is activated and
can trigger the system again. This circuitry monitors sensor inputs and the door trigger, but does not
bypass the ignition trigger at any time. If false alarm prevention circuitry is turned off, the system will
respond to repeated triggers on the sensor inputs and will do so indefinitely. Some states have laws reg-
ulating how many times a security system can trigger before it is considered a nuisance and the vehicle
is towed away.
2-4 PROGRESSIVE DOOR TRIGGER ON/OFF:
The system responds to a door trigger input with a pro-
gressive response. When the door is opened with the system armed, the siren will chirp 10 times prior
to the full triggered sequence. The door trigger is still treated as an instant trigger and closing the door
quickly will not prevent a full triggered sequence from occurring. If the progressive door trigger is pro-
grammed off, the full siren output will occur the moment the door is opened.
2-5 OVERRIDE PULSE COUNT ONE TO FIVE PULSES:
The system can be programmed to count the
number presses of the Override switch before disarming the security system or Anti-Carjacking system.
The factory default setting is one pulse. The unit can be set for two to five pulses using the two-chirp
setting to select the pulse count.
Hidden Switch Option: For added security, the GRAY wire on the two-pin Override switch can be con-
nected to any switch in the vehicle that provides a positive (+) momentary pulse.
2-6 Open Zone Notification ON/OFF:
when programmed on, any active zone input to the system dur-
ing arming will notify you by generating a notification chirp. When programmed OFF, no open zone
(bypass) notification chirps will be generated if any zone is active during arming.
2-7 Ignition-controlled DOMELIGHT SUPERVISION ON/OFF:
If turned on, the system will turn on the
domelight for 30 seconds when the ignition is turned off. The optional domelight supervision feature
must be installed.
2-8 DOUBLE PULSE UNLOCK ON/OFF:
Some vehicles require two pulses on a single wire to unlock
the doors. When the double pulse unlock feature is turned on, the BLUE H2/C wire will supply two neg-
Содержание UNGO ProSecurity S100
Страница 25: ...26 wiring quick reference guide ...