18

menu #2 - advanced features

2-1 SIREN/HORN HONK:

The system can be programmed to output pulses instead of a continuous out-

put when the system is triggered. This is useful to honk the factory horn in applications where a siren
is undesirable. Remember that the unit is only capable of supplying 1 amp of current. A relay will be
required to interface with most factory horn systems.

2-2 SIREN DURATION 30/60 SECONDS:

It is possible to program the unit to sound for 30 or

60 seconds during the triggered sequence. Some states have laws regulating how long a secu-
rity system can sound. When using the Pro Security Programmer, the siren can be programmed

to sound for any length of time ranging from 1 to 180 seconds. Using the SELECT button of the Pro
Security Programmer will adjust the siren duration in one second increments.

2-3 FALSE ALARM PREVENTION CIRCUITRY ON/OFF:

Stops repeated triggering of the same zone. If

one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time
of the third trigger. During that hour, if the system detects a trigger on that zone again, the system resets
the one hour timer. If one hour passes and the zone has not triggered again, the zone is activated and
can trigger the system again. This circuitry monitors sensor inputs and the door trigger, but does not
bypass the ignition trigger at any time. If false alarm prevention circuitry is turned off, the system will
respond to repeated triggers on the sensor inputs and will do so indefinitely. Some states have laws reg-
ulating how many times a security system can trigger before it is considered a nuisance and the vehicle
is towed away.

2-4 PROGRESSIVE DOOR TRIGGER ON/OFF:

The system responds to a door trigger input with a pro-

gressive response. When the door is opened with the system armed, the siren will chirp 10 times prior
to the full triggered sequence. The door trigger is still treated as an instant trigger and closing the door
quickly will not prevent a full triggered sequence from occurring. If the progressive door trigger is pro-
grammed off, the full siren output will occur the moment the door is opened.

2-5 OVERRIDE PULSE COUNT ONE TO FIVE PULSES:

The system can be programmed to count the

number presses of the Override switch before disarming the security system or Anti-Carjacking system.
The factory default setting is one pulse. The unit can be set for two to five pulses using the two-chirp
setting to select the pulse count.

Hidden Switch Option: For added security, the GRAY wire on the two-pin Override switch can be con-
nected to any switch in the vehicle that provides a positive (+) momentary pulse. 

2-6 Open Zone Notification ON/OFF:

when programmed on, any active zone input to the system dur-

ing arming will notify you by generating a notification chirp. When programmed OFF, no open zone
(bypass) notification chirps will be generated if any zone is active during arming.

2-7 Ignition-controlled DOMELIGHT SUPERVISION ON/OFF:

If turned on, the system will turn on the

domelight for 30 seconds when the ignition is turned off. The optional domelight supervision feature
must be installed.

2-8 DOUBLE PULSE UNLOCK ON/OFF:

Some vehicles require two pulses on a single wire to unlock

the doors. When the double pulse unlock feature is turned on, the BLUE H2/C wire will supply two neg-

Содержание UNGO ProSecurity S100

Страница 1: ...installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle s electrical system and components Model S100 installation guide ...

Страница 2: ...ng jumper 12 light flash jumper 13 bypassing sensor inputs 13 module programming routine 13 system features menus 15 menu 1 basic features 15 menu 2 advanced features 16 feature descriptions 16 menu 1 basic features 16 menu 2 advanced features 18 remote programming routine 19 remote configurations 21 standard configuration 21 single button arm disarm configuration 21 diagnostics 22 arm disarm diag...

Страница 3: ...ed to control the starter kill relay It can supply up to 500 mA of current N NO OT TE E If using the H1 1 Orange wire to activate an add on accessory such as window automation pager or voice module a 1Amp diode must be installed to ensure proper operation Insert the diode as shown in the following diagram I Im mp po or rt ta an nt t Never interrupt any wire other than the starter wire RED WHITE 20...

Страница 4: ...Toyota Lexus BMW some Mitsubishi some Mazda and other models N No ot te e For parking light systems that draw 10 amps or more the jumper must be switched to a light flash output see the Programming Jumpers section of this guide A standard automotive SPDT relay must be used on the H1 2 light flash output wire I IM MP PO OR RT TA AN NT T DO NOT connect this wire to a negative vehicle light flash wir...

Страница 5: ...rovide a second unlock pulse when the unlock button is pressed a second time after disarming the system This can be used to unlock the passenger doors when installing progressive door locks H1 4 BLACK WHITE 200 mA domelight supervision output Connect the H1 4 wire to the optional domelight supervision relay as shown in the following diagram H1 5 GREEN door trigger input Most vehicles use negative ...

Страница 6: ... 7 VIOLET door trigger input This type of dome circuit is used in many Ford vehicles Connect the violet wire to a wire that shows 12V when any door is opened This wire will report Zone 3 N NO OT TE E If using a door trigger wire that has a delay Advanced Menu 2 feature 6 or the Pro Security Programmer can be used to turn open zone notification off H1 8 BLACK chassis ground connection Connect this ...

Страница 7: ...is to the RED wire of the siren Connect the BLACK wire of the siren to chassis ground preferably at the same point you connect the control module s BLACK ground wire H1 11 RED 12V constant power input Before connecting this wire remove the supplied fuse Connect to the battery positive terminal or the constant 12V supply to the ignition switch N NO OT TE E Always use a fuse within 12 inches of the ...

Страница 8: ...__ ___ ___ I Im mp po or rt ta an nt t The door lock outputs are low current and should not be attached directly to any high current device they are only to be used to activate relays Blue Unlock Lock Output Empty Unless Using 451M Green Lock Unlock Output H2 A H2 B H2 C I IM MP PO OR RT TA AN NT T Never use this wire to drive anything but a relay or a low current input The transistorized output c...

Страница 9: ...LED in combination with a RED LED override switch 2 Pin BLUE plug The Override switch should be accessible from the driver s seat It plugs into the BLUE port on the side of the unit Since the system features Override by using the remote the button can be well hidden Consider how the button will be used before choosing a mounting location Check for rear clearance before drilling a 9 32 inch hole an...

Страница 10: ...can be mounted horizontally in relation to the windshield or under the dashboard away from metal but range will be diminished Metallic window tint can also affect range so this should be a consideration when determining the mounting location After determining the best mounting location follow these steps 1 Clean the mounting area with a quality glass cleaner or alcohol to remove any dirt or residu...

Страница 11: ... as providing a separate zone for each sensor Diagram for adding optional dual stage sensor to GREEN wire zone 4 BLUE Multiplex Input Inputs shorter than 0 8 seconds will trigger the Warning response while inputs longer than 0 8 sec onds will trigger full alarm sequence and report Zone 2 RED 12V Constant and BLACK Ground Do not use these for anything besides the plug in shock sensor programming ju...

Страница 12: ...engine starting unit as shown in the following diagram module programming routine The Module Programming Routine dictates how the unit operates Due to the number of steps they have been broken up into two menus It is possible to access and change any of the feature settings using the Override switch However this process can be greatly simplified by using the Pro Security Programmer Any of the sett...

Страница 13: ...hird fea ture press and release the switch three times Then press the switch once more and HOLD it The siren will chirp the number of times equal to the step you have accessed 5 Program the Feature While holding the Override switch you can toggle the fea ture on and off using the remote Pressing will select the one chirp setting Pressing will select the two chirp setting See System Features Menus ...

Страница 14: ...ter three seconds the siren chirps twice indicating access to Menu 2 To exit the learn routine do one of the following Close the open door Turn the ignition on No activity for longer than 15 seconds Press the Override switch too many times system features menus menu 1 basic features Items in bold text have been programmed to the default setting at the factory Feature One Chirp Two Chirp Number Set...

Страница 15: ...ng of the system 1 3 IGNITION CONTROLLED DOOR LOCKS ON OFF When turned on the doors will lock three seconds after the ignition is turned on with doors closed and unlock when the ignition is turned off The Pro Security Programmer will display separate steps for ignition lock and ignition unlock They can be programmed on or off independently Feature One Chirp Two Chirp Number Setting Setting 2 1 Sir...

Страница 16: ...he system will passively arm even if a zone is left open or invalid Forced passive arming occurs one hour after the ignition is turned off 1 8 AUTOMATIC ENGINE DISABLE ON OFF Automatic Engine Disable is a full time passive starter disable that works independently of the security system When turned on the orange ground when armed output H1 1 will go active 30 seconds after the ignition is turned of...

Страница 17: ...times a security system can trigger before it is considered a nuisance and the vehicle is towed away 2 4 PROGRESSIVE DOOR TRIGGER ON OFF The system responds to a door trigger input with a pro gressive response When the door is opened with the system armed the siren will chirp 10 times prior to the full triggered sequence The door trigger is still treated as an instant trigger and closing the door ...

Страница 18: ... add remotes to the system or to change button assignments if desired If the system was previously programmed using the Pro Security Programmer the programming routine may be locked If the siren generates one long chirp when attempting to program the unit the pro gramming routine is locked and must be unlocked using the Pro Security Programmer before proceed ing 1 Open a door The GREEN wire H1 5 o...

Страница 19: ...remotes will be erased from memory and the system features will revert to the default settings This is useful in cases where the one of the customer s remotes is lost or stolen This will erase any lost or stolen remotes from the system s memory It can also be used to start from scratch if the remote buttons were programmed incorrectly 5 Release Once the code is learned the Override switch can be r...

Страница 20: ...programmed for standard configuration the remote buttons are assigned to the fol lowing functions operates Arm only operates Disarm only operates Silent Arm Disarm and Channel 2 operates Panic and operate Channel 3 The standard configuration also allows the user to utilize Remote Sensor Bypass a feature that cannot be accessed from a single button arm disarm configuration remote single button arm ...

Страница 21: ...ns 2 Multiplexed BLUE wire of plug in shock sensor Inputs shorter than 0 8 seconds will trigger a Warning Zone response while inputs longer than 0 8 seconds will instantly trigger the full alarm sequence 3 Two stage progresses from Door switch circuit H1 5 GREEN or H1 7 VIOLET warning to full alarm 4 Multiplexed Input GREEN wire of plug in shock sensor Inputs shorter than 0 8 seconds will trigger ...

Страница 22: ... Bypass allows the operator to select which inputs and sensors are active during a par ticular arming cycle For a full description of Remote Sensor Bypass operation for testing purposes refer to the Owner s Guide optional anti car jacking system This optional feature is designed to disable a vehicle during a carjacking event It must be programmed in the features menu and the Starter Kill must be i...

Страница 23: ...the false alarm from memory and then retest the shock sensor For a detailed description of false alarm prevention circuitry see Owner s Guide Door input does not immediately trigger full alarm Instead I hear chirps for the first three seconds That s how the progressive two stage door input works This is the instant response feature of this system Even if the door is closed immediately the system p...

Страница 24: ... solve this problem If the LED indicates that the door caused the trigger you may have programmed the progressive door trigger off See Feature 2 4 in the Feature Descriptions section of this guide The Override switch doesn t work Is it plugged into the correct socket Check the System Features Learn Routine for the programmed Override pulse count Status LED doesn t work Make sure that it is plugged...

Страница 25: ...26 wiring quick reference guide ...

Страница 26: ...Get Started Get Protected Ungo Pro Security 661 W Redondo Beach Blvd Gardena Ca 90247 800 GO CLARION 2003 Directed Electronics Inc All rights reserved NS100 10 03 ...

Отзывы: