background image

11

pro security programmer Interface, 3-Pin BLACK plug

The BLACK three-pin port is provided for programming of the unit. When using the Pro
Security Programmer, it is possible to configure any and all of the programmable functions.
For more information please refer to the guide packaged with the programmer.

mounting the receiver/antenna

Receiver/antenna position should be discussed with the vehicle’s owner prior to installation, since the
antenna may be visible to the vehicle’s operator. 

The best location for the receiver/antenna is centered high on either the front or rear windshield. For
optimal range, the antenna should be mounted vertically. It can be mounted horizontally in relation to
the windshield or under the dashboard away from metal, but range will be diminished. Metallic window
tint can also affect range, so this should be a consideration when determining the mounting location.

After determining the best mounting location, follow these steps:

1.

Clean the mounting area with a quality glass cleaner or alcohol to remove any dirt or residue. 

2.

Plug the receiver/antenna cable into the receiver/antenna.

3.

Mount the receiver/antenna using the supplied double-sided tape. 

4.

Route the receiver/antenna cable to the control module and plug it into the four-pin antenna connector.

IIm

mp

poorrtta

anntt!! To achieve the best possible range, DO NOT leave the antenna cable bundled

under the dash. Always extend the cable full length during installation, regardless of the
antenna mounting location.

Содержание UNGO ProSecurity S100

Страница 1: ...installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle s electrical system and components Model S100 installation guide ...

Страница 2: ...ng jumper 12 light flash jumper 13 bypassing sensor inputs 13 module programming routine 13 system features menus 15 menu 1 basic features 15 menu 2 advanced features 16 feature descriptions 16 menu 1 basic features 16 menu 2 advanced features 18 remote programming routine 19 remote configurations 21 standard configuration 21 single button arm disarm configuration 21 diagnostics 22 arm disarm diag...

Страница 3: ...ed to control the starter kill relay It can supply up to 500 mA of current N NO OT TE E If using the H1 1 Orange wire to activate an add on accessory such as window automation pager or voice module a 1Amp diode must be installed to ensure proper operation Insert the diode as shown in the following diagram I Im mp po or rt ta an nt t Never interrupt any wire other than the starter wire RED WHITE 20...

Страница 4: ...Toyota Lexus BMW some Mitsubishi some Mazda and other models N No ot te e For parking light systems that draw 10 amps or more the jumper must be switched to a light flash output see the Programming Jumpers section of this guide A standard automotive SPDT relay must be used on the H1 2 light flash output wire I IM MP PO OR RT TA AN NT T DO NOT connect this wire to a negative vehicle light flash wir...

Страница 5: ...rovide a second unlock pulse when the unlock button is pressed a second time after disarming the system This can be used to unlock the passenger doors when installing progressive door locks H1 4 BLACK WHITE 200 mA domelight supervision output Connect the H1 4 wire to the optional domelight supervision relay as shown in the following diagram H1 5 GREEN door trigger input Most vehicles use negative ...

Страница 6: ... 7 VIOLET door trigger input This type of dome circuit is used in many Ford vehicles Connect the violet wire to a wire that shows 12V when any door is opened This wire will report Zone 3 N NO OT TE E If using a door trigger wire that has a delay Advanced Menu 2 feature 6 or the Pro Security Programmer can be used to turn open zone notification off H1 8 BLACK chassis ground connection Connect this ...

Страница 7: ...is to the RED wire of the siren Connect the BLACK wire of the siren to chassis ground preferably at the same point you connect the control module s BLACK ground wire H1 11 RED 12V constant power input Before connecting this wire remove the supplied fuse Connect to the battery positive terminal or the constant 12V supply to the ignition switch N NO OT TE E Always use a fuse within 12 inches of the ...

Страница 8: ...__ ___ ___ I Im mp po or rt ta an nt t The door lock outputs are low current and should not be attached directly to any high current device they are only to be used to activate relays Blue Unlock Lock Output Empty Unless Using 451M Green Lock Unlock Output H2 A H2 B H2 C I IM MP PO OR RT TA AN NT T Never use this wire to drive anything but a relay or a low current input The transistorized output c...

Страница 9: ...LED in combination with a RED LED override switch 2 Pin BLUE plug The Override switch should be accessible from the driver s seat It plugs into the BLUE port on the side of the unit Since the system features Override by using the remote the button can be well hidden Consider how the button will be used before choosing a mounting location Check for rear clearance before drilling a 9 32 inch hole an...

Страница 10: ...can be mounted horizontally in relation to the windshield or under the dashboard away from metal but range will be diminished Metallic window tint can also affect range so this should be a consideration when determining the mounting location After determining the best mounting location follow these steps 1 Clean the mounting area with a quality glass cleaner or alcohol to remove any dirt or residu...

Страница 11: ... as providing a separate zone for each sensor Diagram for adding optional dual stage sensor to GREEN wire zone 4 BLUE Multiplex Input Inputs shorter than 0 8 seconds will trigger the Warning response while inputs longer than 0 8 sec onds will trigger full alarm sequence and report Zone 2 RED 12V Constant and BLACK Ground Do not use these for anything besides the plug in shock sensor programming ju...

Страница 12: ...engine starting unit as shown in the following diagram module programming routine The Module Programming Routine dictates how the unit operates Due to the number of steps they have been broken up into two menus It is possible to access and change any of the feature settings using the Override switch However this process can be greatly simplified by using the Pro Security Programmer Any of the sett...

Страница 13: ...hird fea ture press and release the switch three times Then press the switch once more and HOLD it The siren will chirp the number of times equal to the step you have accessed 5 Program the Feature While holding the Override switch you can toggle the fea ture on and off using the remote Pressing will select the one chirp setting Pressing will select the two chirp setting See System Features Menus ...

Страница 14: ...ter three seconds the siren chirps twice indicating access to Menu 2 To exit the learn routine do one of the following Close the open door Turn the ignition on No activity for longer than 15 seconds Press the Override switch too many times system features menus menu 1 basic features Items in bold text have been programmed to the default setting at the factory Feature One Chirp Two Chirp Number Set...

Страница 15: ...ng of the system 1 3 IGNITION CONTROLLED DOOR LOCKS ON OFF When turned on the doors will lock three seconds after the ignition is turned on with doors closed and unlock when the ignition is turned off The Pro Security Programmer will display separate steps for ignition lock and ignition unlock They can be programmed on or off independently Feature One Chirp Two Chirp Number Setting Setting 2 1 Sir...

Страница 16: ...he system will passively arm even if a zone is left open or invalid Forced passive arming occurs one hour after the ignition is turned off 1 8 AUTOMATIC ENGINE DISABLE ON OFF Automatic Engine Disable is a full time passive starter disable that works independently of the security system When turned on the orange ground when armed output H1 1 will go active 30 seconds after the ignition is turned of...

Страница 17: ...times a security system can trigger before it is considered a nuisance and the vehicle is towed away 2 4 PROGRESSIVE DOOR TRIGGER ON OFF The system responds to a door trigger input with a pro gressive response When the door is opened with the system armed the siren will chirp 10 times prior to the full triggered sequence The door trigger is still treated as an instant trigger and closing the door ...

Страница 18: ... add remotes to the system or to change button assignments if desired If the system was previously programmed using the Pro Security Programmer the programming routine may be locked If the siren generates one long chirp when attempting to program the unit the pro gramming routine is locked and must be unlocked using the Pro Security Programmer before proceed ing 1 Open a door The GREEN wire H1 5 o...

Страница 19: ...remotes will be erased from memory and the system features will revert to the default settings This is useful in cases where the one of the customer s remotes is lost or stolen This will erase any lost or stolen remotes from the system s memory It can also be used to start from scratch if the remote buttons were programmed incorrectly 5 Release Once the code is learned the Override switch can be r...

Страница 20: ...programmed for standard configuration the remote buttons are assigned to the fol lowing functions operates Arm only operates Disarm only operates Silent Arm Disarm and Channel 2 operates Panic and operate Channel 3 The standard configuration also allows the user to utilize Remote Sensor Bypass a feature that cannot be accessed from a single button arm disarm configuration remote single button arm ...

Страница 21: ...ns 2 Multiplexed BLUE wire of plug in shock sensor Inputs shorter than 0 8 seconds will trigger a Warning Zone response while inputs longer than 0 8 seconds will instantly trigger the full alarm sequence 3 Two stage progresses from Door switch circuit H1 5 GREEN or H1 7 VIOLET warning to full alarm 4 Multiplexed Input GREEN wire of plug in shock sensor Inputs shorter than 0 8 seconds will trigger ...

Страница 22: ... Bypass allows the operator to select which inputs and sensors are active during a par ticular arming cycle For a full description of Remote Sensor Bypass operation for testing purposes refer to the Owner s Guide optional anti car jacking system This optional feature is designed to disable a vehicle during a carjacking event It must be programmed in the features menu and the Starter Kill must be i...

Страница 23: ...the false alarm from memory and then retest the shock sensor For a detailed description of false alarm prevention circuitry see Owner s Guide Door input does not immediately trigger full alarm Instead I hear chirps for the first three seconds That s how the progressive two stage door input works This is the instant response feature of this system Even if the door is closed immediately the system p...

Страница 24: ... solve this problem If the LED indicates that the door caused the trigger you may have programmed the progressive door trigger off See Feature 2 4 in the Feature Descriptions section of this guide The Override switch doesn t work Is it plugged into the correct socket Check the System Features Learn Routine for the programmed Override pulse count Status LED doesn t work Make sure that it is plugged...

Страница 25: ...26 wiring quick reference guide ...

Страница 26: ...Get Started Get Protected Ungo Pro Security 661 W Redondo Beach Blvd Gardena Ca 90247 800 GO CLARION 2003 Directed Electronics Inc All rights reserved NS100 10 03 ...

Отзывы: