Description
The CLR-C1-ODDG is a supervised wireless sensor that
detects the opening and closing of doors, windows, gates,
garage doors, etc. in extreme environments (-32° to 120°F
(-35.6° to 49°C)). The sensor is constructed with a water-tight
internal gasket to keep the sensor dry and protected from the
elements. The unique design allows for outdoor mounting. The
sensor and magnet are mounted using screws (included) or
straps to secure the sensor to a post.
When activated, the sensor transmits an open (trip) or close
(restore) signal to the panel. The sensor transmits supervisory,
tamper, and low battery (as needed) to the ClareOne panel.
The sensor is powered by (2) replaceable CR 2032, 3-VDC,
Lithium batteries.
Installation
Follow the installation guidelines.
•
Mount the sensor on a non-moving frame or post, allowing
the magnet to move activating the sensor.
•
Mount sensors at least 5 inches above the ground to avoid
damaging them.
•
The sensors can be mounted to either wood or metallic
surfaces.
•
Mounting the sensor on metal can affect the transmitting
range and magnet gap performance. Test the sensor from
the desired location using the installer sensor test before
permanently mounting. (This test can be performed using
the ClareOne panel’s sensors testing feature. Settings >
User/Installer Settings > System Tests > Sensor Test)
•
The magnet should be mounted within 7/8” for wood or
1/2” for metal installations. Based on the magnet mount
spacing, direction of operation, and material of the
mounting surface, the gap for opening varies between 1/8”
and 1 ¾”. Desired operation should be checked before
permanent installation.
•
After mounting the sensor, re-test the sensor using the
procedure in the section “Testing the sensor.”
Mounting the sensor
Mount the sensor using the supplied mounting screws or
straps (not included).
To mount the sensor using mounting screws:
1. Remove the cover screw from the sensor.
2. Mount the sensor using 3 mounting screws and the
magnet using 2.
3. Mount the magnet into the desired location making sure
the magnet alignment mark lines up with the sensor mark.