14
GB
MH 3..7, MDH 3..7
14
Installing the appliance
• Secure the wall bracket to the wall with screws and suitable wall plugs (see fig 4).
Wall bracket is not necessary for M/SMB and M/BG.
• Place the appliance on the wall bracket (see fig. 5).
• The appliance is good for undersink and oversink installation according to the examples of installation
(see fig. 1+2). For undersink installation the water connectors must point vertically upwards, for oversink
installation the water connectors must point vertically downwards.
• Pipe connection (see fig. 6):
Cold water inlet (blue) and hot water outlet (red) are marked by coloured round points on the rating
plate. Connect the colour marked tap pipes to the water inlet/outlet accordingly.
Avoid any kind of mechanical pressure exerted on the appliance, e.g. by water pipes etc.
• After installation, check all connections for leaks.
In order to obtain an optimum water jet at low flow rates, always screw the enclosed jet regulator onto the
tap outlet. This insert fits commercially available sleeves with an M22 or M24 thread.
The following must be observed:
The heater is installed as shown in the immediate vicinity of the outlet in a frost-free room. We guarantee
trouble-free operation only if CLAGE fittings and accessories are used. Note the following during installation:
• Observe the statutory regulations of the respective country, as well as those
of the local electricity and water supply companies.
• Check technical data and the information on the rating plate.
• Ensure that all accessories are removed from the packing materials.
• Easy access to the appliance shall be guaranteed at all times.
An external shut-off valve has to be installed.
• Thoroughly rinse the water pipes before connection.
• Install types MH 3..7 only with special safety taps (open-outlet tap)!
• Optimum operation is ensured at a water flow pressure of 0.2 to 0.4 MPa (2-4 bar),
avoiding pressures exceeding 1 MPa (10 bar).