CKD PPX Series Скачать руководство пользователя страница 1

MJE-PPX No.0040-81V

INSTRUCTION MANUAL

PARECT PRESSURE SWITCH
PPX  series

Read this instruction manual carefully before using this product, particularly the section 
describing safety.
Retain this instruction manual with the product for further consultation whenever necessary.

Precaution

 

● This product is designed for air / non-corrosive gas.

 

 

● Do not touch electric wiring connections (bare live parts): this will cause an electric shock. 

During wiring, keep the power off. Also, do not touch these live parts with wet hands.

 

● A product intended for use in Japan conforms to the Japanese Measurement Act.

Do not use a product intended for use overseas in Japan.

1

PART DESCRIPTION

Connection 
connector

Pressure port

6M type: R

1

/

8

 + M5 female screw

6G type: G

1

/

8

 + M5 female screw

6N type: NPT

1

/

8

 + M5 female screw

PPX

Output 1 operation 
indicator

Lights  up  when  com-
parative output 1 is ON

Mode selection key

Unit display
(Note 1, 2)

Main display

Sub display

Setting value 
DOWN key

Setting value UP key

Output 2 / analogue 
voltage / current out-
put operation indicator

Standard type:

Lights  up  when  com-
parative output 2 is ON

High-function type:

Lights  up  when  analogue 
voltage / current output is set

Notes: 1) In the case of a model that is intended for use outside Japan, attach the unit switch plate corresponds to the set 

pressure unit.

 

2) The product for use inside Japan can be set only to “MPa” or “kPa.”

2

PIPING

 

● When connecting a commercial coupler to the pres-

sure  port,  attach  a  12mm  spanner  (14mm  for  6G 
type)  to  the  pressure  port’s  hexagon  section  to  fix 
the port, and then tighten with a tightening torque of 
9.8N·m or less (M5 female: 1N·m or less). The com-
mercial coupler or pressure port section will be dam-
aged if the tightening torque is excessive. 
Wrap sealing tape around the coupler when connect-
ing to prevent leaks.

12mm spanner

3

MOUNTING

 

● The sensor mounting bracket 

PPX-KL

 is available as an option. When mounting the sensor 

onto the sensor mounting bracket, etc., the tightening torque should be 0.5N·m or less.

M3 (length 6mm) screws 
with washers
(Accessory with 

PPX-KL

)

Sensor mounting bracket 

PPX-KL

 (Optional)

 

● The panel mounting bracket 

PPX-KHS

 (optional), as well as the front cover 

PPX-KCB

 

(optional) are also available.

 

● For  mounting  of  the  panel  mounting  bracket,  refer  to  the  Instruction  Manual  en-

closed with 

PPX-KHS

.

4

WIRING

Connection method

 

● Insert  the  cable  with  connector 

PPX-C

□  into 

this  product’s  connection  connector  section 

Disconnection method

 

● Pressing  the  release  lever  of  the  cable  with 

connector, pull out the connector.

Cable with connector 

PPX-C

Release lever 

<Recommended product>

Contact: SPHD-001T-P0.5
Housing: PAP-04V-S 
[JST Mfg. Co., Ltd.]

Note:  Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector break. 

<Connection connector pin arrangement>

1

2

3

4

Connector pin No.

Terminal name

1

+V

2

Comparative output 1

3

Standard type: Comparative output 2
High-function type: Analogue voltage / current output or external input

4

0V

5

I/O CIRCUIT DIAGRAMS

NPN output type

Standard type

Main circuit

(Brown) +V

(Black)
Comparative output 1

(White) Comparative output 2

(Blue) 0V

Load

Load

100mA max.

100mA max.

+

12 to 24V DC
±10%

-

High-function type

Main circuit

(Brown) +V

(White)
Analogue voltage / current output 
or external input (Notes 1, 2, 3)
(Black)
Comparative output 1

(Blue) 0V

Load

100mA max.

5V

1kΩ

+

12 to 24V DC
±10%

-

PNP output type

Standard type

Main circuit

(Brown) +V

(Black) Comparative output 1

(White)
Comparative output 2

(Blue) 0V

Load

Load

100mA max.

100mA max.

+

12 to 24V DC
±10%

-

High-function type

Main circuit

(Brown) +V

(White)
Analogue voltage / current output 
or external input (Notes 1, 2, 3)

(Black)
Comparative output 1

(Blue) 0V

Load

100mA max.

1kΩ

+

12 to 24V DC
±10%

-

Notes: 1) When the analogue current is output, the output load resistance should be 250Ω max.
 

2) Take care that when the analogue current is output, 5V or more voltage generates. 

 

3) When using the analogue voltage output, be careful to the input impedance of the connected device.

 

 

Furthermore, note that if the cable is extended, the cable resistance will cause the voltage to drop.

6

OUTPUT MODE AND OUTPUT OPERATION

 

● The EASY mode, hysteresis mode or window comparator mode can be selected as 

the output mode for comparative output 1 and comparative output 2.
Refer  to 

<Comparative  output  1  /  2  output  mode  setting>

  in  “

8

MENU  SET-

TING MODE

” for details.

EASY mode

 

● ON / OFF of the comparative output is controlled in this mode.

Pressure

P

0

ON

OFF

Comparative 
output

H (Hysteresis)

Notes: 1) 
 

 

Refer to 

 in “

9

PRO MODE

” for setting.

 

2) “ 

 ” is displayed for comparative output 1 and “ 

 ” for comparative output 2 on the sub-display.

Hysteresis mode

 

● The comparative output ON / OFF state can be controlled with randomly set hyster-

esis in this mode.

0

Pressure

Comparative 
output

H (Hysteresis)

Hi

Lo

ON

OFF

H: 1digit or more

2 digits or more when 
using psi unit

Note:  “ 

 ” or “ 

 ” is displayed for comparative output 1 and “ 

 ” or “ 

 ” for comparative output 2 on the 

sub-display.

Отзывы: