CKD 2000-W Series Скачать руководство пользователя страница 1

 

 

 

 

 

 

 
 
 

Combination:

 

C

□□□

0 Series 

 

 

(excluding Oil Mist Filter) 

Filter Regulator: 

 

 

W

000, W

100 Series 

Air Filter:

 

F

000

 Series

 

Regulator:

 

R

000, R

100 Series 

Lubricator:

 

L

000

 Series

 

INSTRUCTION MANUAL

 

•  Read this Instruction Manual before using the product. 

•  Read the safety notes carefully. 

•  Keep this Instruction Manual in a safe and convenient place for future reference. 

F.R.L. Unit 

Modular Type SELEX F.R.L. Series 

SM-189671-A/8

 

Содержание 2000-W Series

Страница 1: ...Series Regulator R 000 R 100 Series Lubricator L 000 Series INSTRUCTION MANUAL Read this Instruction Manual before using the product Read the safety notes carefully Keep this Instruction Manual in a s...

Страница 2: ...hout notice The product is intended for users who have basic knowledge about materials piping electricity and mechanisms of pneumatic components CKD shall not be responsible for accidents caused by pe...

Страница 3: ...gs and precautions described in this Instruction Manual to ensure device safety Although various safety measures have been adopted in the product customer s improper handling may lead to an accident T...

Страница 4: ...s machine brake circuit and safety measures For applications where life or properties may be adversely affected and special safety measures are required Exception is made if the customer consults with...

Страница 5: ...1 2 Unpacking 3 1 3 Mounting 3 1 4 Piping 5 2 USAGE 8 2 1 Operation 10 3 MAINTENANCE AND INSPECTION 12 3 1 Daily Inspection 13 3 2 Periodic Inspection 13 3 3 How to Discharge Drainage 14 3 4 How to P...

Страница 6: ...ide pressure and the secondary side pressure to the atmospheric pressure at the same time Lowering the primary side pressure of a regulator not equipped with a check valve to the atmospheric pressure...

Страница 7: ...liphatic hydrocarbon Methyl chloride ethylene chloride methylene chloride acetylene chloride chloroform trichlene berklene and carbon tetrachloride Organic solvent cleaning solution for metal trichlen...

Страница 8: ...et if selected in the model number Attach the C type bracket to the product as shown in the figure below before piping Panel mounting of the regulator excluding 8000 W Series When the panel mounting n...

Страница 9: ...t apply pressure exceeding the full scale pressure specified for the pressure gauge The pressure gauge may become damaged Use extreme care when using a pressure gauge with a full scale pressure of 0 2...

Страница 10: ...the direction of flow by checking the direction of the arrow Prevent foreign matters from entering the pipes while piping and connecting the fitting Be careful not to allow cutting chips from the pip...

Страница 11: ...down with your fingers to attach it firmly When using a liquid seal material be careful not to apply it to resin parts The resin parts can become damaged and this may lead to a failure or malfunction...

Страница 12: ...le as an option for F6000 W and F8000 W Series By assembling the differential pressure gauge GA400 8 P02 to the differential pressure detection ports the degree of clogging in the filter element or oi...

Страница 13: ...sed circuit when using the regulators in parallel as shown below If a closed circuit is required attach a check valve to the OUT side of each regulator Do not use a distributor to divide air into lubr...

Страница 14: ...the product correctly Check the primary side pressure and set the regulator pressure so that the pressure rises Lock the knob after setting Check the arrow indicating the air inlet before connecting R...

Страница 15: ...cally so that it does not fall below the lower limit Lubricating L1000 W Pressure in the bowl can be released by turning the filling plug For operation refer to Removing the filling plug lubricator Oi...

Страница 16: ...djusting dome in the O direction and to lower the drip rate turn the dome in the S direction If the dome is hard to turn by hand place a coin in the slit on the top of the dome and use it to turn the...

Страница 17: ...air filter so that it does not accumulate beyond the upper limit If drainage flows into the secondary side operation faults may occur in the device For plastic bowls make sure that drainage does not a...

Страница 18: ...this Instruction Manual before maintenance and inspection Check that the product operates properly before starting use 3 2 Periodic Inspection In order to use the product under optimum conditions perf...

Страница 19: ...ck is as follows 1000 Series 0 1 N m Others 0 5 N m Metal bowl with automatic drain Drainage is discharged automatically when it is accumulated or can be discharged manually It is operated in the same...

Страница 20: ...ct all parts of the assembly at the same time Be careful not to lose any part Lubricator Supply oil to the lubricator bowl periodically so that the amount of oil does not fall below the lower limit Se...

Страница 21: ...lean or replace the O ring Bowl is damaged Stop supplying the compressed air remove the bowl assembly and replace the bowl assembly When primary side pressure is applied air leaks from gap between cov...

Страница 22: ...avoided if the customer s machinery or device into which the product is incorporated had functions and structures generally provided in the industry Failure caused by reasons unforeseen at the level o...