background image

English

Design and Specification are subject to change without notice.

CITIZEN is a registered trademark of Citizen Holdings Co., Japan.

CITIZEN es una marca registrada de Citizen Holdings Co., Japón.

INSTRUCTION MANUAL

FOR

DIGITAL BLOOD PRESSURE MONITOR

REF

 CH-406D

0801

Содержание CH-406D

Страница 1: ...English INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 406D 0801...

Страница 2: ...of one measurement Keep a continuing record of your blood pressure variations A complete picture can only be obtained from a large number of readings 9 Emotional stress tends to cause your blood press...

Страница 3: ...ading 10 The gure below shows the blood pressure classi cations under the WHO standards Remarks The graph is not exact but may be used as a guide in understanding non invasive blood pressure measureme...

Страница 4: ...n in your arms consult your physician before using the monitor Failure to do so could be hazardous to your health 8 Measurement may not be possible for anyone with insuf cient blood ow to the area whe...

Страница 5: ...re the blood pressure monitor in locations exposed to direct sunlight high temperatures over 60 C 140 F low temperatures below 20 C 4 F high relative humidity over 95 or excessive amounts of dust 2 DO...

Страница 6: ...e WEEE Directive Directive 2002 96 EC and is effective only within European Union Reference European standard This product complies with EC instructions 93 42 EEC Medical Device Directive and with the...

Страница 7: ...lies with the European regulations and bears the CE mark CE 0197 The quality of the device has been veri ed and is in line with the provisions of the EC council directive 93 42 EEC EN IEC60601 1 2 200...

Страница 8: ...Eng 8 English Component names COMPONENT NAMES AND LOCATIONS LCD display Air hose socket Air hose connector MODE Switch SET Switch MEMORY Switch START STOP Switch a Stand by Cuff Air hose...

Страница 9: ...o display icons DEVICE DESCRIPTION Date display Time display De ation Battery icon Error icon Memory number display Systolic blood pressure display Diastolic blood pressure display Pulse display Measu...

Страница 10: ...ry compartment cover 2 Insert the batteries into the compartment Insert the batteries taking care to ensure that the positive m and negative terminals are positioned correctly 3 Close the battery comp...

Страница 11: ...appears on the display when the START STOP switch is pressed t 4 new AA Alkaline batteries Do not use rechargeable batteries Do not use alkaline and manganese batteries together The monitor is powere...

Страница 12: ...used as the only power supply for the monitor unplugging the AC adapter will erase the data stored in the monitor s memory It is recommended that you make a note of any important data When only batter...

Страница 13: ...lood pressure in the same posture at the same time every day Taking measurements while sitting 1 Place your arm on a table or similar surface with your forearm extended 2 It is important to have the a...

Страница 14: ...arm so that the air hose is to the left of your palm The arm cuff should be put directly against your skin but can also be used over a lightweight sleeve If you are wearing a thick top remove it Do n...

Страница 15: ...at the cuff is snug around your arm and then secure the end to the Velcro Carefully place the cuff on your arm taking care to use the correct tightness The tightness is correct if you can readily slid...

Страница 16: ...1 Hold down the SET switch on to advance the setting continuously Press the MODE switch to set each correct number 3 Correcting the Month Date and Time of the clock 1 Press MODE switch month starts as...

Страница 17: ...g After the blood pressure measurement is taken the systolic pressure diastolic pressure and pulse rate are shown on the display for 1 minute after which the display turns off unless other instruction...

Страница 18: ...rst the memory number and then the last set of data stored Press the MEMORY recall switch again This recalls and displays the second last set of data stored Each time you press this switch the unit di...

Страница 19: ...rectly Replace all four batteries with new batteries Insert the new alkaline batteries correctly making sure that the positive and negative terminals are positioned correctly Error icon This appears w...

Страница 20: ...lood returns to the heart Systolic Diastolic Artery Artery Left atrium Left ventricle Left atrium Left ventricle Dilation The artery wall expands Contraction Normal state is restored to the artery wal...

Страница 21: ...Knowing what affects your blood pressure helps you to better monitor your health Q What is the bene t of measuring my blood pressure at home A Blood pressure measurements taken at home give reliable d...

Страница 22: ...ad the batteries in the correct direction No measurements can be taken Check whether the measurement icon is displayed Attach the arm cuff properly Check whether the arm cuff is applied correctly Did...

Страница 23: ...ation Automatic constant speed de ation system Rated voltage 6V DC 6W direct current Exhaust Electromagnetic quick exhaust valve Power supply 4 AA alkaline batteries LR6 or optional AC DC adapter 6V...

Страница 24: ...Design and Specification are subject to change without notice CITIZEN is a registered trademark of Citizen Holdings Co Japan CITIZEN es una marca registrada de Citizen Holdings Co Jap n...