CITC MANIAC II 100123 Скачать руководство пользователя страница 12

11 

5.9

 

Hanging / Floor Operation 

 

  To switch from floor operation to hanging operation, disconnect the 2 brass quick-connect 

fittings from the Fluid Input and Fluid Output. 

  Open side tank door and slide tank out of the inner chamber located in the base of the 

machine.  Set aside. 

  Lock X and Y axis locks. 

  Gently place MANIAC II™ on its side so the bottom of the machine is accessible. 

  Attach the included hanging brackets by lining up the tabs on the brackets with the holes 

on the base of the machine. 

  Spin both screw handles clockwise until they snap in place.  If need be, use a wrench to 

make certain they are not under tightened.   Repeat for remaining hanging bracket. 

  Attach mounting clamps (c-clamp) rated for the appropriate weight capacity to the 

hanging bracket.  You must use two mounting clamps to mount the MANIAC II™. 

  Make certain that the structure or surface onto which you are mounting this machine can 

support the weight. 

  Mount the MANIAC II™ securely to a rigging point, such as an elevated platform or truss 

along with a safety cable.  Reinstall fluid tank (now inverted) into the inner fluid tank 
chamber. 

  Unlock X and Y axis locks before operating. 

 

5.10

 

Cleaning and storage 

 

  It is recommended that after 40 hours of continuous use or before this machine is put into 

storage, you run a 95% distilled water and 5% distilled white vinegar mixture through the 
machine.  Run a small amount of distilled water through machine and turn off. 

  When machine is unplugged and cooled down, use a vacuum (or dry compressed air) 

and a soft brush to remove dust collected on the air vents and external surfaces. 

  To prevent damage, do not spin any of the cooling fans using compressed air.  

 

 

WARNING: To prevent damage, do not store, transport or ship with 

fog fluid inside! 

 

 

5.11

 

Troubleshooting 

 

Problem: 

Solution: 

Pan or Tilt chattering 

- Check X and Y Axis Locks. 
- Check DMX signal. 

Loud Humming and No Fog 

- Check Fluid Tank. 

Not Fogging 

- Machine may be heating up. 
- Check DMX address. 
- Check DMX signal. 

Remote Not Working 

- See Section 5.7 
- Check Battery 

 

 

 

Содержание MANIAC II 100123

Страница 1: ...THE MANIAC II RGBA LED MOVING HEAD FOGGER Operating Instructions P N 100123 230 VAC w DMX...

Страница 2: ...eration of this unit please take some time to read the manual carefully We believe you will enjoy years of great service if you properly care for your new MANIAC II RGBA LED MOVING HEAD FOGGER CITC 14...

Страница 3: ...ating the MANIAC II 5 1 Selecting The Location 5 2 Electrical Power Requirements 5 3 Hooking Things Up 5 4 Unlocking the X Y Axis Locks 5 5 Operation 5 6 DMX Control 5 7 Wireless Remote 5 8 System Men...

Страница 4: ...Wireless Remote Control 1 x Power Cord 1 x Operating Instructions Booklet 2 Accessories CITC 15 Second SmartFog Fluid Available in 1 Gallon or 5 Gallon Containers Custom Fluid Supplier 250060 Maniac...

Страница 5: ...machine without disconnecting power first o Do not operate if any of the service panels or covers are missing o RISK OF ELECTRICAL SHOCK This device is supplied with a grounding conductor To reduce ri...

Страница 6: ...d 230V circuit for operation The MANIAC II uses a 8 amp breaker for 230V If you have any doubts about the capacity or grounding of your existing circuits consult a qualified electrician 5 3 Hooking Th...

Страница 7: ...s Clip off ends o Reattach the brass fittings to the Liquid Input and Liquid Output o Insert the other ends of the tubing into the 1 gallon or 5 gallon container Make sure the ends of the tubing are a...

Страница 8: ...7 1 LED Housing 2 Spray Nozzle 3 Fluid Tank 4 Fluid Input Connector 5 Fluid Outlet Connector 6 LCD Menu Display 7 3 Pin DMX 8 5 Pin DMX 9 Power Connector 10 Power Switch 11 Wireless Remote Antenna...

Страница 9: ...ady to emit fog The MANIAC II is designed to produce short bursts of fog Running the fog for an extended amount of time will cool the heating element used to produce the fog This will cause the MANIAC...

Страница 10: ...ick will use that channel and the nine following channels to control the MANIAC II The following is a list of the channel attributes CHANNEL VALUE FUNCTION 1 0 9 10 255 FOG OUTPUT OFF ON 2 0 9 10 255...

Страница 11: ...ote included only controls the fog ON and OFF function of the MANIAC II The buttons both work the same They turn the fog on when depressed and off when released 5 8 System Menu MENU This button allows...

Страница 12: ...upport the weight Mount the MANIAC II securely to a rigging point such as an elevated platform or truss along with a safety cable Reinstall fluid tank now inverted into the inner fluid tank chamber Un...

Страница 13: ...min Preheat Time About 5 minutes DMX Channels 10 LED Lamps 5W x 24 6 each R G B A Fluid Type CITC SmartFog Fluid Fluid Capacity 1 31 qt 1 2L Pan 540 Full rotation takes approximately 2 seconds Tilt 27...

Страница 14: ...ability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there from No liability i...

Страница 15: ...ace appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the customer 6 Limi...

Отзывы: