background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Maintenance

15

AJ1032

Cleaning Air Filter

Air filter removes foreign matter and condensate from 
supply air as it passes through filter. Frequency at 
which the filter baffle plate and filter element should 
be cleaned depends upon amount of condensate and 
foreign matter in supply air. Condensate level should 
not rise above baffle. This is the sign of a faulty auto-
drain which would need to be cleaned, replaced or 
repaired.

Erratic regulator operation or loss of regulation is 
almost always due to dirt.

The following steps outline the procedure for cleaning 
air filter.

1. Close and lock air supply line shut-off valve.

2. Remove filter bowl. Use a strap wrench if 

required. Disassemble regulator, making notes as 
a guide for reassembly.

3. Clean parts with household soap (Dawn™, 

Ivory™, etc.) and blow out body with 
compressed air.

NOTE: DO NOT use cleansing agents such as 
acetone, benzene, carbon tetrachloride, gasoline, or 
toluene, which are damaging to plastic sight glass.

4. Reassemble per notes from step 2. Ensure o-ring 

is in position on filter bowl. Tighten bowl to filter 
body. Tighten slightly more than hand tight.

5. Open air service shut-off valve.

6. Check for leaks and adjust as necessary.

Cleaning Steam Strainer

Strainer removes foreign matter from steam. 
Frequency at which strainer must be cleaned is 
dependent upon amount of foreign matter suspended 
in steam. Removing and checking strainer screen for 
cleanliness after two weeks or after 80 hours of 
operation is recommended. If little or no foreign 
matter has collected on screen, time between 
inspections can be increased accordingly.

Cleaning Customer-Furnished Steam 
Traps

Some steam traps are provided with internal steam 
strainers. These strainers should be cleaned. Refer to 

Cleaning Steam Strainer

.

All repairable traps should be opened at least once a 
year to visually check operating mechanisms.

Remove sediment and dirt from trap body. Mechanism 
may require cleaning by immersing in appropriate 
cleaning fluid.

NOTE: Check instructions provided with trap or 
with trap manufacturer for appropriate cleaning 
fluids.

Содержание AJ1032

Страница 1: ...1292 Sales Fax 502 585 3625 Service Parts Fax 502 681 1275 www cissellmfg com Mighty Mite and Super Laundry Presses Refer to Page 3 for Model Numbers SCR1529C SCR1529C Part No AJ1032 February 2005 Ke...

Страница 2: ......

Страница 3: ...ety Instructions 5 Introduction 7 Nameplate Location 7 Parts Ordering Information 7 General Description 7 Optional Equipment 7 Operation 9 Operating Controls 9 Pre Operating Services 10 Press Operatio...

Страница 4: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 AJ1032 Notes...

Страница 5: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 3 AJ1032 Model Identification Information in this manual is applicable to the following models LDBB CMMBB LDCC CMMCCY...

Страница 6: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT AJ1032 4 Notes...

Страница 7: ...Do not tamper with the controls 7 Do not repair or replace any part of the press or attempt any servicing unless specifically recommended in the user maintenance instructions or in published user repa...

Страница 8: ...igns and labels are also placed on the press Those signs and labels are limited messages Where needed further explanations are provided in the manual These signs are to be inspected for readability an...

Страница 9: ...essing of damp garments Major press components are Steam heated head and buck One air cylinder dedicated to closing head AND automatically apply pressing pressure once head is closed An adjustable muf...

Страница 10: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT AJ1032 8 Notes...

Страница 11: ...ut off and lockout valve REGULATOR Reduces supply air pressure to operating air pressure 80 psi Adjust air pressure regulator so operating air pressure is 80 5 psi DOWNSTREAM AIR RELIEVING SHUT OFF AN...

Страница 12: ...heat Press Operation One complete pressing operation is described in the following steps Presses WITHOUT Timers or Presses WITH Timer Set to OFF Position 1 Perform pre operating services 2 If press i...

Страница 13: ...can be opened at any time during timer controlled pressing by pressing OPEN pushbutton Item 5 Figure 2 6 Hang or fold pressed article as soon as possible to preserve finish Post Operating Services Per...

Страница 14: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT AJ1032 12 Notes...

Страница 15: ...actions to be taken are listed in Table 2 To avoid possible serious injury ALWAYS shut off services to press BEFORE doing ANY maintenance service setup adjustments or repair tasks Shut off AND lock o...

Страница 16: ...or unreadable Every two weeks Inspect steam strainers in steam inlet and outlet lines and in traps Clean steam strainer if dirt is present Monthly Inspect customer furnished steam traps per instructio...

Страница 17: ...oline or toluene which are damaging to plastic sight glass 4 Reassemble per notes from step 2 Ensure o ring is in position on filter bowl Tighten bowl to filter body Tighten slightly more than hand ti...

Страница 18: ...nths Use a premium high temperature EP2 grease Lubricate with one shot of grease from a low pressure grease gun If rod end fittings do not have grease fittings squirt a few drops of oil on rod ends B...

Страница 19: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Maintenance 17 AJ1032 Figure 3 SCR102N B0159 INSPECTION AND LUBRICATION POINTS A C B A SYMBOLS GREASE GUN OIL CAN D...

Страница 20: ...To decrease flow rate turn adjusting screw clockwise Likewise turn counterclockwise to increase oil flow 3 Use ISO VG 32 grade oil refer to Table 3 Refer to Filling Air Line Lubricator for filling ins...

Страница 21: ...re with a pyrometer or comparable measuring device Head temperature should be 325 to 340 F If temperature is below recommended range review possible causes below Clogged steam strainer Clean steam str...

Страница 22: ......

Отзывы: