E-20
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Appendix E Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Older Migration and Upgrade Procedures
Step 7
If your system has rear panel SSDs, ensure that they are in the correct SSD bays to communicate with
the M4 server node that you just installed:
•
If your single server node is in server bay 1 (see
), only Server 1 bays SSD1 and SSD2
can be used.
•
If your single server node is in server bay 2, only Server 2 bays SSD1 and SSD2 can be used.
Figure E-2
Rear Panel Connectors for Setup
Step 8
Reconnect power cables to the system. Wait for approximately five minutes to allow the system to boot
up.
Step 9
Connect a KVM cable (Cisco PID N20-BKVM) to the KVM connector on the server node at the rear of
the system (see
). Connect a USB keyboard and a VGA monitor to the KVM cable.
Step 10
Open the Cisco IMC Configuration Utility:
a.
Press and hold the front panel power button for four seconds to boot the system. Watch the screen
for the prompt to press F8.
b.
During bootup, press
F8
when prompted to open the Cisco IMC Configuration Utility.
This utility has three windows that you can toggle between by pressing F1 or F2.
Step 11
The utility prompts you to change the default user password. Set a default user password before
continuing.
Step 12
Set the CMCs in all SIOCs and the BMCs in all server nodes to the factory defaults.
The
Factory Default
check box has two options but you must perform two resets in this order:
a.
Select
Chassis Controller Configuration
and save your changes. Both CMCs in the SIOCs are set
to the factory default state.
b.
Select
Server Controller Configuration
and save your changes. The server node is set back to its
factory default state and the server/host reboots.
1
40-Gb QSFP ports (two on each SIOC)
3
KVM console connector on each server node
2
10/100/1000 dedicated management port