C
ISCO
S
YSTEMS
P
UBLICATION
H
ISTORY
170 W
EST
T
ASMAN
D
R
.
AN
J
OSE
, CA, 95134
EV
B.3
O
CTOBER
17, 2016
WWW
CISCO
COM
Cisco UCS B420 M4
Blade Server
Страница 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 3 OCTOBER 17 2016 WWW CISCO COM Cisco UCS B420 M4 Blade Server ...
Страница 2: ...ECURE DIGITAL CARDS 26 STEP 9 ORDER INTERNAL USB 3 0 DRIVE OPTIONAL 27 STEP 10 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 28 STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT OPTIONAL 31 STEP 12 CHOOSE SERVICE and SUPPORT LEVEL 32 STEP 13 CHOOSE LOCAL KVM I O CABLE OPTIONAL 37 SUPPLEMENTAL MATERIAL 38 System Board 38 DIMM and CPU Layout 40 DIMM Population Order 41 Network Connectivity 45 VIC 1340 12...
Страница 3: ...as capacity grows and the large power envelope of the UCS 5108 Blade Server Chassis means the UCS B420 can handle up to 3 TB of memory without compromise to CPU speed or core count Up to four UCS B420 M4 Blade Servers can be installed in the UCS 5108 Blade Server Chassis The UCS B420 M4 Blade Server is centrally managed using Cisco UCS Manager Cisco UCSM provides a single management interface for ...
Страница 4: ...or information about the KVM local I O cable that plugs into the console connector a cable is included with every Cisco UCS 5100 Series blade server chassis accessory kit see CHOOSE LOCAL KVM I O CABLE OPTIONAL on page 37 5 Left blade ejector handle 12 Reset button access 6 Asset pull handle a blank asset tag is provided on which you can add your own label or sticker or you can use a marker to wri...
Страница 5: ... 5100 series blade server chassis CPU Up to four Intel E5 4600 v3 or v4 series processor family CPUs 2 and 4 CPU configurations are supported on the UCS B420 M4 Chipset Intel C610 chipset Memory 48 total slots for registered ECC DIMMs I O Three configurable adapter slots One slot supports the Cisco VIC 1340 1240 adapter only Two additional slots support Cisco adapters and Cisco UCS Storage Acceler...
Страница 6: ... server inventory health and system event logs Cisco UCS Diagnostics for Cisco UCS B Series Blade Servers The Cisco UCS Blade Server Diagnostics tool for Cisco UCS Blade Servers enables you to verify the health of the hardware components on your servers The diagnostics tool provides a variety of tests to exercise and stress the various hardware subsystems on the Cisco UCS Blade Servers such as mem...
Страница 7: ...or SOLID STATE DRIVES OPTIONAL page 19 STEP 6 CHOOSE ADAPTERS page 21 STEP 7 ORDER A TRUSTED PLATFORM MODULE OPTIONAL page 25 STEP 8 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS page 26 STEP 9 ORDER INTERNAL USB 3 0 DRIVE OPTIONAL page 27 STEP 10 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 28 STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT OPTIONAL page 31 STEP 12 CHOOSE SERVICE and SUPPORT...
Страница 8: ...ring product ordering CPUs Memory Disk drives Cisco adapters such as the VIC 1340 VIC 1240 VIC 1380 VIC 1280 and Port Expander Cisco UCS Storage Accelerators Table 2 PID of the Base UCS B420 M4 Blade Server Product ID PID Description UCSB B420 M4 UCS B420 M4 Blade Server with no CPU memory HDD SSD or adapter cards NOTE Use the steps on the following pages to order servers with the configurable com...
Страница 9: ... 9 6 2400 UCS CPU E5 4650E E5 4650 V4 2 2 105 35 14 9 6 2400 UCS CPU E5 4655E E5 4655 V4 2 5 135 30 8 9 6 2400 UCS CPU E5 4640E E5 4640 V4 2 1 105 30 12 8 0 2133 UCS CPU E5 4627E1 Notes 1 The UCS CPU E5 4627E CPU does not support Hyper Threading technology E5 4627 V4 2 6 135 25 10 8 0 2400 UCS CPU E5 4620E E5 4620 V4 2 1 105 25 10 8 0 2133 UCS CPU E5 4610E E5 4610 V4 1 8 105 25 10 6 4 1866 Intel X...
Страница 10: ...U Configuration Choose four identical CPUs from any one of the rows of Table 3 Notes The system will run at the lowest CPU or DIMM clock speed System speed is also dependent on how many DIMMs are populated per channel For 2 CPU systems only 24 DIMM slots are functional channels A H See Table 12 on page 23 for supported adapter combinations in 2 CPU systems For 4 CPU systems all 48 DIMM slots are f...
Страница 11: ...p to three DIMMs per channel DPC as shown in Figure 3 Figure 3 UCS B420 M4 Memory Organization CPU 1 CPU 2 48 DIMMS 4 memory channels per CPU 3 DIMMs per channel CPU 3 CPU 4 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H Channel M Channel N Channel O Channel P Channel I Channel J Channel K Channel L A1 A2 A3 B3 C3 D3 I3 J3 K3 I3 M3 N3 O3 P3 E3 F3 G3 H3 B1 B2 C1 C2 ...
Страница 12: ...o populated channels provides data Notes DIMM configuration rules The minimum configuration is 1 DIMM per CPU The order in which DIMMs must be installed in a channel is Bank 1 blue socket then Bank 2 black socket then Bank 3 white socket You cannot mix DIMM capacities within a bank You can mix DIMM capacities within a channel Table 4 Supported DDR4 DIMMs and Memory Mirroring Option Product ID PID ...
Страница 13: ...systems shipping with E5 4600 v3 series processor family CPUs DIMM speeds are as shown in Table 5 Table 6 and Table 7 Table 5 DIMM Speeds for 2133 MHz E5 4600 v3 Series CPUs DPC DIMM Type 64 GB TSV 16 32 GB DR 8 GB SR 1DPC 2133 2133 2133 2DPC 2133 2133 2133 3 DPC 1600 1866 1600 Table 6 DIMM Speeds for 1866 MHz E5 4600 v3 Series CPUs DPC DIMM Type 64 GB TSV 16 32 GB DR 8 GB SR 1DPC 1866 1866 1866 2...
Страница 14: ...nk x4 16 GB 1 2 V DIMM FREQ 2400 CPU FREQ 2400 1 DPC 2400 2400 2400 2400 2 DPC 2400 2400 2400 2400 3 DPC 2133 1866 2133 2133 DIMM FREQ 2133 CPU FREQ 2400 1 DPC NA 2133 2133 2133 2 DPC NA 2133 2133 2133 3 DPC NA 1866 1866 1866 DIMM FREQ 2400 CPU FREQ 2133 1 DPC 2133 2133 2133 2133 2 DPC 2133 2133 2133 2133 3 DPC 1866 1866 1866 1866 DIMM FREQ 2133 CPU FREQ 2133 1 DPC NA 2133 2133 2133 2 DPC NA 2133 ...
Страница 15: ...ith memory mirroring Select 4 DIMMs per CPU installed in bank 1 8 DIMMs per CPU installed in banks 1 2 or 12 DIMMs per CPU installed in banks 1 2 3 DIMM and CPU Frequencies DIMMs per Channel LRDIMM speed quad rank x4 64 GB 1 2 V RDIMM speed dual rank x4 32 GB 1 2 V LRDIMM speed quad rank x4 32 GB 1 2 V LRDIMM speed single rank x4 16 GB 1 2 V DIMM FREQ 2133 CPU FREQ 1866 1 DPC NA 1866 1866 1866 2 D...
Страница 16: ...nking panels must be installed Table 9 Card Cage and RAID Ordering Options Product ID PID PID Description UCSB MRAID12G1 Notes 1 The UCSB MRAID 12G RAID controller runs iMegaRAID which has a lower capability software stack provides RAID 0 1 levels and has no support for caching Note that you cannot upgrade from this RAID controller to the to UCSB MRAID12G HE RAID controller Cisco FlexStorage 12G S...
Страница 17: ...ive Bays Top View Figure 5 UCS B420 M4 With and Without Drive Bays Front View RAID Controller integrated in drive bay Disk Drive Bays 4 a Server with four drive bays b Server with no drive bays Blanking Panels a Server with four drive bays b Server with no drive bays Blanking Panels Blanking Panel ...
Страница 18: ... RAID controller RAID 0 1 10 5 6 3 Two Drive Bays with RAID 0 1 10 Choose the following One UCSB MRAID12G This provides two drive bays installed on the left side of the blade server viewed from the front The RAID controller is integrated in the drive bays and provides RAID 0 1 10 The two right hand bays are fitted with blanking panels to maintain proper cooling airflow 4 Two Drive Bays with RAID 0...
Страница 19: ...o UCS Manager Release 3 1 2b and later versions Table 10 Supported Hot Plug Drives Product ID PID PID Description Drive Type Capacity HDDs 12 Gbps Drives UCS HD600G15K12G 600 GB 12G SAS 15K RPM SFF HDD SAS 600 GB UCS HD450G15K12G 450 GB 12G SAS 15K RPM SFF HDD SAS 450 GB UCS HD300G15K12G 300 GB 12G SAS 15K RPM SFF HDD SAS 300 GB UCS HD12TB10K12G 1 2 TB 12G SAS 10K RPM SFF HDD SAS 1 2 TB UCS HD900G...
Страница 20: ...ve types is supported but performance may be impacted Multiple RAID volumes are supported RAID volumes should use the same media type 6 Gbps Drives UCS SD16TBKS4 EV 1 6 TB 2 5 inch Enterprise Value 6G SATA SSD Intel 3510 SATA 1 6 TB UCS SD480GBKS4 EV 480 GB 2 5 inch Enterprise Value 6G SATA SSD Intel 3510 SATA 480 GB UCS SD240GBKS4 EV 240 GB 2 5 inch Enterprise Value 6G SATA SSD SATA 240 GB UCS SD...
Страница 21: ...s 8 x 10 Gbs Unified ports for a total of 160 Gbs see Figure 26 on page 56 VIC 1340 supports dual 4 x 10 Gbs Unified I O ports Port Expander enables additional ports on the VIC 1340 to create either dual 4 x 10 Gbs or dual native 40G Unified I O ports and VIC 1380 supports 8 x 10 Gbs Unified ports for a total of 160 Gbs see Figure 26 on page 56 Creates up to 256 fully functional unique and indepen...
Страница 22: ...8P Cisco UCS VIC 1380 mezzanine adapter Adapter 3 UCSB MLOM 40G 01 Cisco UCS VIC 1240 modular LOM for blade servers Adapter 1 UCS VIC M82 8P Cisco UCS VIC 1280 mezzanine adapter Adapter 3 Port Expander Card for VIC Option UCSB MLOM PT 01 Cisco UCS Port Expander Card for VIC This is a hardware option to enable an additional 4 ports of the VIC 1340 or VIC 1240 bringing the total capability of the VI...
Страница 23: ...support 2 x 62xx or 2 x 63xx VIC 1340 Port Expander Card VIC 1380 1602 1601 80 no support 2 x 62xx or 2 x 63xx not populated not populated VIC 1380 803 801 40 no support 2 x 62xx or 2 x 63xx VIC 1340 Cisco UCS Storage Accelerator Fusion io not populated 803 804 40 no support 2 x 62xx or 2 x 63xx VIC 1340 not populated Cisco UCS Storage Accelerator Fusion io 40 40 20 no support 2 x 62xx or 2 x 63xx...
Страница 24: ...ulated not populated 40 40 20 no support 2 x 62xx or 2 x 63xx VIC 1340 Port Expander Card not populated 803 803 3 Dual 40G via 4x10 port channel configuration 40 no support 2 x 62xx or 2 x 63xx VIC 1340 Port Expander Card VIC 1380 160 1602 80 no support 2 x 62xx or 2 x 63xx VIC 1340 not populated VIC 1380 1204 4 Dual native 40G interface 120 60 no support 2 x 62xx or 2 x 63xx VIC 1340 not populate...
Страница 25: ...rm Module Product ID PID PID Description UCSX TPM2 001 Trusted Platform Module for UCS SPI based UCSX TPM2 002 Trusted Platform Module 2 0 for UCS servers NOTE TPM installation is supported after factory However a TPM installs with a one way screw and cannot be replaced upgraded or moved to another server If a server with a TPM is returned the replacement server must be ordered with a new TPM If t...
Страница 26: ...cards is supported The SDHC card ordering information is listed in Table 16 Supported Configurations 1 Select one or two Cisco Flexible Flash secure digital cards Select up to two 32 GB SD cards or two 64 GB SD cards 2 Do not mix 64 GB cards and 32 GB cards Table 16 PIDs for Secure Digital Card s Product ID PID PID Description UCS SD 64G S 64 GB SD Card for UCS servers UCS SD 32G S 32 GB SD Card f...
Страница 27: ... STEP 9 ORDER INTERNAL USB 3 0 DRIVE OPTIONAL You can order one optional internal USB 3 0 drive The USB drive ordering information is listed in Table 17 Table 17 USB 3 0 Drive Product ID PID PID Description UCS USBFLSHB 16GB UCS Servers 16 GB Flash USB Drive ...
Страница 28: ...rformance Manager Express 90 days evaluation Nexus 1000V for Hyper V and vSphere N1K VSG UCS BUN Nexus 1000V Adv Edition for vSphere Paper License Qty 1 IMC Supervisor CIMC SUP B10 IMC Supervisor Branch Mgt SW for C E Series up to 1K Svrs CIMC SUP B02 IMC Supervisor Branch Mgt SW for C E Series up to 250 Svrs UCS Multi Domain Manager UCS MDMGR 100S UCS Multi Domain Manager Central Per Server Licen...
Страница 29: ...Plus 1 CPU 1 yr Support Required VMW VSP STD 5A VMware vSphere 6 Standard 1 CPU 5 yr Support Required SLES SAP SLES SAP 2S2V 1S SLES for SAP Apps 1 2 CPU 1 2 VM Priority 1 Yr SnS SLES SAP 2SUV 1S SLES for SAP Apps 1 2 CPU Unl VM Priority 1 Yr SnS SLES SAP 2S2V 3S SLES for SAP Apps 1 2 CPU 1 2 VM Priority 3 Yr SnS SLES SAP 2SUV 3S SLES for SAP Apps 1 2 CPU Unl VM Priority 3 Yr SnS SLES SAP 2S2V 5S ...
Страница 30: ...rprise Svr 1 2 CPU Unl VM Prio 3 Yr SnS SLES 2S2V 5S SUSE Linux Enterprise Svr 1 2 CPU 1 2 VM Prio 5 Yr SnS SLES 2SUV 5S SUSE Linux Enterprise Svr 1 2 CPU Unl VM Prio 5 Yr SnS SLES 2S HA 1S SUSE Linux High Availability Ext 1 2 CPU 1yr SnS SLES 2S HA 3S SUSE Linux High Availability Ext 1 2 CPU 3yr SnS SLES 2S HA 5S SUSE Linux High Availability Ext 1 2 CPU 5yr SnS SLES 2S GC 1S SUSE Linux GEO Cluste...
Страница 31: ...PID Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU Unlimited VM Rec Media MSWS 12R2 ST2S RM Windows Server 2012 R2 Standard 2 CPU 2 VMs Recovery Media MSWS 12R2 DC2S RM Windows Server 2012 R2 Datacen 2 CPU Unlimited VM Rec ...
Страница 32: ...ment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Service includes flexible hardware r...
Страница 33: ...r service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS i...
Страница 34: ... identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations Table 22 Partner Support Service for UCS Product ID PID Service Level GSP On Site Description CON PSJ1 B420...
Страница 35: ...abilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 25 Table 24 UCS Computing Combined Support Service Product ID PID Service Level GSP On Site Description CON NCF2 B420M4 NCF2 No CMB ...
Страница 36: ...omputing System see this URL http www cisco com en US products ps10312 serv_group_home html Table 25 Drive Retention Service Options Service Description Service Program Name Service Level GSP Service Level Product ID PID SMARTnet for UCS Service with Drive Retention UCS DR UCSD7 24x7x4 Onsite CON UCSD7 B420M4 UCSD7 8x5xNBD Onsite CON UCSD5 B420M4 SMARTnet for UCS HW ONLY Drive Retention UCS HW DR ...
Страница 37: ...use With this cable you can create a direct connection to the operating system and the BIOS running on the server The local KVM I O cable ordering information is listed in Table 26 Figure 6 Local KVM I O Cable Table 26 Local KVM I O Cable Product ID PID PID Description N20 BKVM Local KVM I O cable for UCS servers console port 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 s...
Страница 38: ...e 7 Figure 7 UCS B420 M4 System Board 1 Ejector thumbscrew 7 Heat sink and CPU underneath 2 SD card slots 8 CPU heat sink install guide pins 3 Modular storage subsystem connector 9 Trusted Platform Module TPM 4 USB memory 10 Adapter 1 slot supports the Cisco VIC 1340 1240 adapter only 305015 1 2 5 7 8 8 12 8 8 7 9 7 7 4 6 6 10 11 11 6 6 6 6 6 6 3 3 1 ...
Страница 39: ... SUPPLEMENTAL MATERIAL 39 5 CMOS battery 11 Adapter cards Adapter 2 is the slot on the left when facing the server and partially covers Adapter 1 Adapter 3 is the slot on the right facing the server 6 DIMM slots 12 Diagnostic button ...
Страница 40: ...s per channel CPU 3 CPU 4 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H Channel M Channel N Channel O Channel P Channel I Channel J Channel K Channel L A1 A2 A3 B3 C3 D3 I3 J3 K3 I3 M3 N3 O3 P3 E3 F3 G3 H3 B1 B2 C1 C2 D1 D2 Bank 1 Bank 2 Bank 3 E1 E2 F1 F2 G1 G2 H1 H2 Bank 1 Bank 2 Bank 3 Bank 1 Bank 2 Bank 3 M1 M2 N1 N2 O1 O2 P1 P2 I1 I2 J1 J2 K1 K2 I1 I2 Bank 1 ...
Страница 41: ...L2 black DIMM slots Bank 3 I3 J3 K3 and L3 white DIMM slots CPU4 Channels M N O and P Bank 1 M1 N1 O1 and P1 blue DIMM slots Bank 2 M2 N2 O2 and P2 black DIMM slots Bank 3 M3 N3 O3 and P3 white DIMM slots DIMM Population Order Populate the DIMMs for a CPU according to Table 27 Table 27 DIMM Population Order per CPU DIMMs per CPU Populate CPU 1 Slots Populate CPU 2 Slots Populate CPU 3 Slots Popula...
Страница 42: ... A1 B1 C1 A2 B2 C2 A3 B3 C3 E1 F1 G1 E2 F2 G2 E3 F3 G3 I1 J1 K1 I2 J2 K2 I3 J3 K3 M1 N1 O1 M2 N2 O2 M3 N3 O3 10 Not recommended for performance reasons 11 Not recommended for performance reasons 12 A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 E1 F1 G1 H1 E2 F2 G2 H2 E3 F3 G3 H3 I1 J1 K1 L1 I2 J2 K2 L2 I3 J3 K3 L3 M1 N1 O1 P1 M2 N2 O2 P2 M3 N3 O3 P3 Table 28 DIMM Population Quick Reference for CPU 1 for 1 2...
Страница 43: ...ysical Layout The overall DIMM and CPU physical layout is shown in Figure 9 Figure 9 DIMM and CPU Layout 1 Channel A D DIMMs for CPU 1 3 Channel I L DIMMs for CPU 3 2 Channel E H DIMMs for CPU 2 4 Channels M P DIMMs for CPU 4 305020 CPU 1 CPU 2 CPU 4 CPU 3 1 4 2 3 ...
Страница 44: ...on the blade server The DIMM slots are contiguous to their associated CPU Figure 10 Physical Representation of DIMMs and CPUs B3 B2 B1 A3 A2 A1 G1 G2 G3 H1 H2 H3 C1 C2 C3 D1 D2 D3 F3 F2 F1 E3 E2 E1 L3 L2 L1 K3 K2 K1 P3 P2 P1 O3 O2 O1 I1 I2 I3 J1 J2 J3 M1 M2 M3 N1 N2 N3 CPU 4 Front Rear CPU 1 CPU 3 CPU 2 305018 ...
Страница 45: ...the 5108 blade server chassis 4 x 10 Gb KR ports from the VIC 1340 1240 adapter 4 x 10 Gb KR ports from the Port Expander 8 x 10 Gb KR ports from the VIC 1380 1280 adapter 4 x 10 Gb from a Cisco Storage Accelerator when placed in adapter slot 2 similar to the Cisco UCS Port Expander Card for VIC Requires UCSM 2 2 4b or later The resulting aggregate bandwidth is 160 Gb 80 Gb to each Fabric Extender...
Страница 46: ...r Storage Accelerator VIC 1380 1280 Adapter CPU 1 CPU 4 CPU 2 PCIe x16 PCIe x16 PCIe x16 4 x 10G KR 4 x 10G KR 4 x 10G KR 2 x 10G KR 2 x 10G KR 2 x 10G KR 2 x 10G KR adapter slot 1 for VIC 1240 adapter slot 2 adapter slot 3 Fabric Extender A UCS 5108 Blade Server Chassis To Fabric Interconnects To Fabric Interconnects B420 M4 Blade Server Fabric Extender B ...
Страница 47: ...lled in adapter slot 2 the four 10G KR ports between the adapters are used for port expansion otherwise they are unused With the Port Expander installed there are up to eight 10 Gb network interfaces to each Fabric Extender depending on the Fabric Extender installed as represented in Figure 12 Figure 12 VIC 1340 1240 Connectivity VIC 1340 1240 Adapter adapter slot 2 adapter slot 1 for VIC 1240 Por...
Страница 48: ...ed 80 Gb Figure 14 on page 49 VIC 1340 Not populated VIC 1380 120 Gb Figure 15 on page 50 VIC 1240 Port Expander Card VIC 1280 160 Gb Figure 16 on page 50 VIC 1340 Port Expander Card2 VIC 1380 160 Gb Figure 17 on page 51 Not populated Not populated VIC 1280 80 Gb Figure 18 on page 51 Not populated Not populated VIC 1380 80 Gb Figure 19 on page 52 VIC 1340 Cisco UCS Storage Accelerator3 3 If runnin...
Страница 49: ...andwidth to each Fabric Extender Figure 14 VIC 1340 and Port Expander in Adapter Slot 2 adapter slot 3 empty VIC 1340 1240 Adapter adapter slot 2 adapter slot 1 for VIC 1340 1240 Port Group A Port Group B CPU 1 PCIe x16 No Adapter Installed No Adapter Installed adapter slot 3 CPU2 CPU4 2304 Fabric Extender B 2304 Fabric Extender A EMPTY EMPTY 10G KR 10G KR 10G KR 10G KR If a Port Expander is insta...
Страница 50: ... 1240 Port Expander in Adapter Slot 2 and VIC 1280 in Adapter Slot 3 2304 Fabric Extender B 2304 Fabric Extender A VIC 1340 Adapter VIC 1380 Adapter No Adapter Installed adapter slot 3 adapter slot 2 adapter slot 1 for VIC 1340 Port Group A Port Group B CPU 1 PCIe x16 PCIe x16 CPU 2 EMPTY 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR Port Group A Port Group B ...
Страница 51: ...y The result is 40 Gb of bandwidth to each Fabric Extender Figure 18 VIC 1280 VIC 1340 slot empty and adapter slot 2 empty 2304XP Fabric Extender A VIC 1340 Adapter Port Expander Adapter Port Group A Port Group B CPU 1 PCIe x16 adapter slot 2 adapter slot 1 for VIC 1240 VIC 1380 Adapter adapter slot 3 PCIe x16 CPU 2 Port Group A Port Group B 2304XP Fabric Extender B CPU4 If a Port Expander is inst...
Страница 52: ...0 Gb of bandwidth to each Fabric Extender This configuration requires 4 CPUs Figure 20 VIC 1340 Cisco UCS Storage Accelerator in slot 2 and adapter slot 3 empty 2304 Fabric Extender B 2304 Fabric Extender A No VIC 1340 adapter installed No adapter installed VIC 1380 Adapter Native 40G interface Native 40G interface adapter slot 3 adapter slot 2 adapter slot 1 for VIC 1340 CPU 1 PCIe x16 PCIe x16 C...
Страница 53: ...identical Cisco UCS Storage Accelerator adapters are installed in slots 2 and 3 but the one in slot 3 provides no network connectivity This configuration requires 4 CPUs Figure 22 VIC 1340 Cisco UCS Storage Accelerator in slots 2 and 3 VIC 1340 Adapter adapter slot 1 for VIC 1340 Port Group A Port Group B CPU1 PCIe x16 CPU 2 2304 Fabric Extender B 2304 Fabric Extender A 10G KR 10G KR 10G KR 10G KR...
Страница 54: ...Not populated 80 Gb Figure 24 on page 55 VIC 1340 1240 Not populated VIC 1380 1280 120 Gb Figure 25 on page 56 VIC 1340 1240 Port Expander Card VIC 1380 1280 160 Gb Figure 26 on page 56 Not populated Not populated VIC 1380 80 Gb Figure 27 on page 57 VIC 1340 Cisco UCS Storage Accelerator3 3 f running 2 2 4b or greater and equipped with either storage accelerator SKU UCSB F FIO 1300MP or UCSB F FIO...
Страница 55: ...d Port Expander in Adapter Slot 2 adapter slot 3 empty 2208 Fabric Extender B 2208 Fabric Extender A VIC 1340 1240 Adapter adapter slot 2 adapter slot 1 for VIC 1340 1240 Port Group A Port Group B CPU 1 PCIe x16 No Adapter Installed No Adapter Installed adapter slot 3 CPU2 CPU4 EMPTY EMPTY 10G KR 10G KR 10G KR 10G KR If a Port Expander is installed in slot 2 CPU4 is optional If a Storage Accelerat...
Страница 56: ...rt Expander in Adapter Slot 2 and VIC 1380 1280 in Adapter Slot 3 2208 Fabric Extender B 2208 Fabric Extender A VIC 1380 1240 Adapter VIC 1380 1280 Adapter No Adapter Installed adapter slot 3 adapter slot 2 adapter slot 1 for VIC 1340 1240 Port Group A Port Group B CPU 1 PCIe x16 PCIe x16 CPU 2 EMPTY 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR Port Group A P...
Страница 57: ...on requires 4 CPUs Figure 28 VIC 1340 Cisco UCS Storage Accelerator in slot 2 and adapter slot 3 empty 2208 Fabric Extender B 2208 Fabric Extender A No VIC 1340 adapter installed No adapter installed VIC 1380 Adapter adapter slot 3 adapter slot 2 adapter slot 1 for VIC 1340 CPU 1 PCIe x16 PCIe x16 CPU 2 EMPTY EMPTY 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR Port Group A Port Group B C...
Страница 58: ...erator adapters are installed in slots 2 and 3 but the one in slot 3 provides no network connectivity This configuration requires 4 CPUs Figure 30 VIC 1340 Cisco UCS Storage Accelerator in slots 2 and 3 2208 Fabric Extender A 2208 Fabric Extender B VIC 1340 Adapter adapter slot 1 for VIC 1340 Port Group A Port Group B CPU1 PCIe x16 CPU 2 10G KR 10G KR 10G KR 10G KR Cisco UCS Storage Accelerator ad...
Страница 59: ...40 Not populated Not populated 20 Gb Figure 31 on page 60 VIC 1340 Port Expander Card Not populated 40 Gb Figure 32 on page 60 VIC 1340 1240 Not populated VIC 1380 1280 60 Gb Figure 33 on page 61 VIC 1340 1240 Port Expander Card VIC 1380 1280 80 Gb Figure 34 on page 61 Not populated Not populated VIC 1380 40 Gb Figure 35 on page 62 VIC 1340 Cisco UCS Storage Accelerator Not populated 40 Gb Figure ...
Страница 60: ...e 32 VIC 1340 and Port Expander in Adapter Slot 2 adapter slot 3 empty VIC 1340 1240 Adapter No Adapter Installed adapter slot 2 adapter slot 1 for VIC 1340 1240 Port Group A Port Group B CPU 1 PCIe x16 adapter slot 3 CPU 2 2204XP Fabric Extender B 2204XP Fabric Extender A EMPTY EMPTY 10G KR 10G KR No Adapter Installed CPU4 If a Port Expander is installed in slot 2 CPU4 is optional If a Storage Ac...
Страница 61: ...Gb of bandwidth to each Fabric Extender Figure 34 VIC 1340 1240 Port Expander and VIC 1380 1280 2204XP Fabric Extender B 2204XP Fabric Extender A VIC 1340 1240 Adapter VIC 1380 1280 Adapter No adapter installed adapter slot 3 adapter slot 2 adapter slot 1 for VIC 1340 1240 Port Group A Port Group B CPU 1 PCIe x16 PCIe x16 CPU 2 EMPTY 10G KR 10G KR 10G KR 10G KR 10G KR 10G KR Port Group A Port Grou...
Страница 62: ...Extender This configuration requires 4 CPUs Figure 36 VIC 1340 Cisco UCS Storage Accelerator in slot 2 slot 3 empty 2204XP Fabric Extender B 2204XP Fabric Extender A No VIC 1340 installed VIC 1380 Adapter No adapter installed adapter slot 3 adapter slot 2 adapter slot 1 for VIC 1340 CPU 1 PCIe x16 PCIe x16 CPU 2 EMPTY EMPTY 10G KR 10G KR 10G KR 10G KR Port Group A Port Group B CPU4 If a Port Expan...
Страница 63: ...or adapters are installed in slots 2 and 3 but the one in slot 3 provides no network connectivity This configuration requires 4 CPUs Figure 38 VIC 1340 1240 Cisco UCS Storage Accelerator in slots 2 and 3 VIC 1340 Adapter adapter slot 1 for VIC 1340 Port Group A Port Group B CPU1 PCIe x16 CPU 2 2204XP Fabric Extender B 2204XP Fabric Extender A 10G KR 10G KR Cisco UCS Storage Accelerator adapter slo...
Страница 64: ...ue Height 1 95 in 50 mm Width 16 5 in 419 mm Depth 24 4 in 620 mm Weight Base server weight 17 780 lb 8 1 kg Minimally configured server with 2 CPUs 2 heatsinks 2 RDIMMs 1 Mezz 4 HDD blank 21 098 lb 9 57 kg Minimally configured server with 2 CPUs 2 heatsinks 2 LRDIMMs 1 Mezz 4 HDD blank 21 206 lb 9 62 kg Fully configured server with 4 CPU 4 heatsinks 48 RDIMMs 3 Mezz 2 RAID 4 HDD 30 704 lb 13 93 k...