background image

C

ISCO

 S

YSTEMS

P

UBLICATION

 H

ISTORY

 

170 W

EST

 T

ASMAN

 D

R

.

 

S

AN

 J

OSE

, CA, 95134

R

EV

 A.11

O

CTOBER

 8, 2013

 

WWW

.

CISCO

.

COM

Spec Sheet

This product has been 
discontinued

Cisco UCS B200 M2

Blade Server

Содержание UCS B200 M2

Страница 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 11 OCTOBER 8 2013 WWW CISCO COM Spec Sheet This product has been discontinued Cisco UCS B200 M2 Blade Server ...

Страница 2: ...HOOSE HARD DISK DRIVES or SOLID STATE DRIVES 14 STEP 5 CHOOSE A PCIe MEZZANINE CARD 15 STEP 6 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 16 STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT 19 STEP 8 CHOOSE SERVICE and SUPPORT LEVEL 20 ORDER OPTIONAL KVM CABLE 24 SUPPLEMENTAL MATERIAL 25 Motherboard 25 DIMM and CPU Layout 25 Memory Population Recommendations 26 TECHNICAL SPECIFICATIONS 28 Dimensions ...

Страница 3: ...lade server using Intel s Xeon 5500 and 5600 Series processors with 12 DIMM slots one mezzanine slot to hold an adapter card and up to two solid state disk SSD drives or hard disk drives HDDs Up to eight half width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis Figure 1 Cisco UCS B200 M2 Blade Server ...

Страница 4: ...work link status LED 2 Blade ejector handle 8 Blade health LED 3 Blade ejector handle captive screw 9 Console connector1 Notes 1 For information about the KVM device included in the chassis accessory kit that plugs into the console connector see ORDER OPTIONAL KVM CABLE on page 24 4 Drive bay 1 hot pluggable 10 Reset button access 5 Drive bay 2 hot pluggable 11 Beaconing LED and button 6 Power but...

Страница 5: ...Expansion slots Accommodates one mezzanine adapter card Storage controller LSI Logic 1064e controller and integrated RAID RAID 0 and 1 supported Internal storage devices Up to two optional front accessible hot pluggable 2 5 inch small form factor SFF SAS or SATA solid state disk SSD or hard disk HDD drives Video The server CIMC chip includes a Matrox G200 core The first 8 MB of memory are allocate...

Страница 6: ...P 1 VERIFY BASE SKU page 7 STEP 2 CHOOSE CPU S page 8 STEP 3 CHOOSE MEMORY page 10 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES page 14 STEP 5 CHOOSE A PCIe MEZZANINE CARD page 15 STEP 6 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 16 STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT page 19 STEP 8 CHOOSE SERVICE and SUPPORT LEVEL page 20 ...

Страница 7: ... UPG B200 M2 base server Includes KVM cable Does not include CPUs Memory Disk drives Mezzanine adapter card Table 2 PID of the Base B200 M2 Blade Server Product ID PID Description N20 B6625 1 UPG UCS B200 M2 Blade Server w o CPU memory HDD mezzanine NOTE Use the steps on the following pages to configure the server with the components that you want to include ...

Страница 8: ... Selecting lower speed DIMMs If you use an X5650 CPU which can support up to 1333 MHz DIMMs with 1066 MHz DIMMs the DIMMs will be clocked at the lower speed of 1066 MHz Selecting higher speed DIMMs If you use 1333 MHz DIMMs with an E5620 which can support up to 1066 MHz DIMMs the DIMMS will be clocked at the lower speed of 1066 MHz UCS CPU X5687 X5687 3 60 130 12 4 6 4 GT s 1333 A01 X0115 X5690 3 ...

Страница 9: ...PU Configuration Choose two identical CPUs from any one of the rows of Table 3 on page 8 Caveats You must select either one CPU or two identical CPUs For optimal performance select DIMMs with the highest clock speed for a given processor If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result ...

Страница 10: ...are DIMMs Clock speed 1333 or 1066 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 5 or 1 35 V Registered DDR3 ECC registered DIMMs RDIMMs supporting Intel SDDC Memory is organized with three memory channels per CPU with up to two DIMMs per channel as shown in Figure 3 Figure 3 B200 M2 Memory Organization ...

Страница 11: ...the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 4 Available DDR3 DIMMs Product I...

Страница 12: ...PU configuration with memory mirroring Select two or four DIMMs per CPU The DIMMs will be placed by the factory as shown in the following table Select the memory mirroring option N01 MMIRROR as shown in Table 4 on page 11 Number of DIMMs DIMM Placement in Channels Channel C is not used with memory mirroring 2 1 DIMM in Channel A 1 DIMM in Channel B 4 2 DIMMs in Channel A 2 DIMMs in Channel B Numbe...

Страница 13: ...viceability RAS mirroring will go into effect on only two channels with two DIMMS per channel you cannot implement RAS on three channels In this case two DIMMS would go unused For more information regarding memory see DIMM and CPU Layout on page 25 NOTE For memory mirroring DIMM pairing across buses must be identical If you only have two DIMMs they need to be the same PID because you have one DIMM...

Страница 14: ...You cannot mix HDD and SSD drives You cannot mix SAS and SATA drive types Table 5 Available Hot Pluggable Sled Mounted SSDs Product ID PID PID Description Drive Type Capacity HDDs A03 D146GC2 146 GB SAS 15K RPM SFF HDD SAS 146 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB UCS HDD300GI2F105 300 GB SAS 15k RPM 2 5in HDD SAS 300 GB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF SATA 500 GB A03...

Страница 15: ...rds you have selected please check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod_technical_reference_list html Table 6 Available PCIe Option Cards Product ID PID PID Description Converged Network Adapters CNA N20 AC0002 UCS M81KR Virtual Interface Card PCIe 2 port 10Gb UCS VIC M82 8P Cisco UCS VIC 1280 dual 40 Gb capable Virtual Interface Card N20 AQ010...

Страница 16: ...nterprise Server SLES 1A SLES 1yr subscription svcs required 0 media SLES 3A SLES 3yr subscription svcs required 0 media UCS SLES TERMS Acceptance of Terms Standalone SLES License for UCS Servers Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2S 1G 3A RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2S 4G 1A RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2S 4G 3A RHE...

Страница 17: ...ar Support Rqd VMW VS5 STD 5A VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMW VS5 ENT 1A VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rqd VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rqd VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd VMW VS5 ENT 5...

Страница 18: ...he SERVER VMW VC5 STD 5A VMware vCenter 5 Server Standard 5 yr support required UCS VMW TERMS Acceptance of Terms Standalone VMW License for UCS Servers Table 7 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID ...

Страница 19: ...EL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08RS ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU Unlimited V...

Страница 20: ...siness continuity the TAM provides crisis management leadership and your IT staff receives expedited access to Cisco s Technical Assistance Center TAC Please note This service has qualification criteria Your company must have 1 2M of UCS equipment 200 blades and a single location to qualify for this service level Choose the desired service listed in Table 9 Unified Computing Support Service For su...

Страница 21: ...rization RMA is required You can choose a service listed in Table 11 Table 10 UCS Computing Support Service Product ID PID On Site Description CON UCS1 B200 M2 No UC Support 8X5XNBD CON UCS2 B200 M2 No UC Support 8X5X4 CON UCS3 B200 M2 No UC Support 24x7x4 CON UCS4 B200 M2 No UC Support 24x7x2 CON UCS5 B200 M2 Yes UC Support 8X5XNBD CON UCS6 B200 M2 Yes UC Support 8X5X4 CON UCS7 B200 M2 Yes UC Sup...

Страница 22: ...ities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 12 NOTE Cisco does not offer a certified drive destruction service as part of this service Table 12 Drive Retention Service Options Serv...

Страница 23: ...ww cisco com en US products ps10312 serv_group_home html UCS Warranty Plus With Drive Retention UC PLUS DR UCWD2 8x5x4 CON UCWD2 B200 M2SFF UCWD3 24x7x4 CON UCWD3 B200 M2SFF UCWD4 24x7x2 CON UCWD4 B200 M2SFF UCWD5 8x5xNBD Onsite CON UCWD5 B200 M2SFF UCWD6 8x5x4 Onsite CON UCWD6 B200 M2SFF UCWD7 24x7x4 Onsite CON UCWD7 B200 M2SFF UCWD8 24x7x2 Onsite CON UCWD8 B200 M2SFF Table 12 Drive Retention Ser...

Страница 24: ...or a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 13 Figure 4 KVM Cable Table 13 KVM Cable Product ID PID PID Description 37 1016 01 KVM Cable 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 serial connector 4 Two port USB 2 0 connector fo...

Страница 25: ...and C Bank 1 A1 B1 and C1 blue DIMM slots Bank 2 A2 B2 and C2 black DIMM slots CPU2 Channels D E and F Bank 1 D1 E1 and F1 blue DIMM slots Bank 2 D2 E2 and F2 black DIMM slots The DIMM and CPU physical layout is shown in Figure 6 The 6 DIMM slots at the upper right are controlled by the CPU on the right CPU1 and the 6 DIMM slots at the lower left are controlled by the CPU on the left CPU2 1 Hard d...

Страница 26: ...if problems arise moving them to the preferred arrangement should help NOTE The DIMMs at the upper right cannot communicate with the DIMMs at the lower left unless both CPUs are installed Table 14 Preferred DIMM Population Order DIMMs per CPU CPU 1 Installed Slots CPU 2 Installed SLots 1 A1 D1 2 A1 B1 D1 E1 3 A1 B1 C1 D1 E1 F1 4 A1 A2 B1 C1 D1 D2 E1 F1 5 A1 A2 B1 B2 C1 D1 D2 E1 E2 F1 6 A1 A2 B1 B2...

Страница 27: ... the same type This goes for both speed and size Do not mix different sized DIMMs or DIMMs with different clock rates in the same blade server Doing so will cause a significant loss of performance Your selected CPU s can have some effect on performance DIMMs can be run in a 1 DIMM per channel or a two DIMM per channel configuration Each of these arrangements can provide different behavior ...

Страница 28: ...or at http www cisco com assets cdc_content_elements flash dataCenter cisco_ucs_power_calculator Table 15 UCS B200 M2 Dimensions and Weight1 Notes 1 The system weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs memory DIMMs and other optional items Parameter Value Height 1 95 in 50 mm Width 8 00 in 203 mm Depth 24 4 in 620 mm Weight 13 5 lb...

Отзывы: