D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
Copyright © 2017 Cisco Systems, Inc. All rights reserved.
87
Cisco TelePresence MX700 and MX800
API Reference Guide
SerialPort configuration
xConfiguration SerialPort Mode
Enable/disable the serial port (COM port).
Requires user role: ADMIN, INTEGRATOR
Default value: On
USAGE:
xConfiguration SerialPort Mode:
Mode
where
Mode
: Off/On
Off: Disable the serial port.
On: Enable the serial port.
xConfiguration SerialPort BaudRate
Define the baud rate (data transmission rate, bits per second) for the serial port.
Other connection parameters for the serial port are: Data bits: 8; Parity: None; Stop bits: 1; Flow
control: None.
Requires user role: ADMIN, INTEGRATOR
Default value: 115200
USAGE:
xConfiguration SerialPort BaudRate:
BaudRate
where
BaudRate
: 9600/19200/38400/57600/115200
Set a baud rate from the baud rates listed (bps).
xConfiguration SerialPort LoginRequired
Define if login shall be required when connecting to the serial port.
Requires user role: ADMIN
Default value: On
USAGE:
xConfiguration SerialPort LoginRequired:
LoginRequired
where
LoginRequired
: Off/On
Off: The user can access the codec via the serial port without any login.
On: Login is required when connecting to the codec via the serial port.