D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
Copyright © 2017 Cisco Systems, Inc. All rights reserved.
51
Cisco TelePresence MX700 and MX800
API Reference Guide
xConfiguration Audio Output Line [1..6] Equalizer Mode
Define the equalizer mode for the audio source that is connected to the output line.
Requires user role: ADMIN, INTEGRATOR
Default value: Off
USAGE:
xConfiguration Audio Output Line
n
Equalizer Mode:
Mode
where
n
: Unique ID that identifies the audio line output. Range: 1..6
Mode
: Off/On
Off: No equalizer.
On: Enable the equalizer for the audio output line.
xConfiguration Audio Output Line [1..6] Level
Define the audio level on the line output connector.
See the Audio Level table in the Physical Interface Guide for Cisco TelePresence SX80 for a
complete overview of the values represented in dB.
Requires user role: ADMIN, INTEGRATOR
Default value: -10
USAGE:
xConfiguration Audio Output Line
n
Level:
Level
where
n
: Unique ID that identifies the audio line output. Range: 1..6
Level
: Integer (-24..0)
Select a value between -24 and 0, in steps of 1 dB.
xConfiguration Audio Output Line [1..6] Mode
Define the mode for the audio line output.
Requires user role: ADMIN, INTEGRATOR
Default value: On
USAGE:
xConfiguration Audio Output Line
n
Mode:
Mode
where
n
: Unique ID that identifies the audio line output. Range: 1..6
Mode
: Off/On
Off: Disable the audio line output.
On: Enable the audio line output.
xConfiguration Audio Ultrasound MaxVolume
This setting applies to the Intelligent Proximity feature. Set the maximum volume of the ultra-
sound pairing message.
Requires user role: ADMIN, INTEGRATOR
Default value: 70
USAGE:
xConfiguration Audio Ultrasound MaxVolume:
MaxVolume
where
MaxVolume
: Integer (0..90)
Select a value in the specified range. If set to 0, the ultrasound is switched off.
Introduction
About the API
xConfiguration
Appendices
xCommand
xStatus
xConfiguration