11-20
Cisco SCE 8000 10GBE Software Configuration Guide
OL-30621-02
Chapter 11 Redundancy and Failover
System Upgrades
Step 7
Remove the force failure condition in that platform.
Step 8
After the former active Cisco SCE platform recovers and is ready to work, it may remain the standby or
can be manually switched back to active.
Simultaneous Upgrade of Firmware and Application
Step 1
In the standby Cisco SCE platform:
a.
Uninstall the application.
b.
Upgrade the firmware (this includes a reboot).
c.
Install the new application.
Step 2
Force-failure in the active Cisco SCE platform.
This makes the updated Cisco SCE platform the active one, and it begins to give the NEW service.
Step 3
Repeat step 1 for the (now) standby Cisco SCE platform.
Since this includes a reboot, it is not necessary to undo the force failure command.