Cisco PowerVu D9858 Скачать руководство пользователя страница 1

 

 

 

 

Cisco D9858 Advanced Receiver 
Transcoder Software Version 4.50 
Installation and Configuration Guide 

 

 

 

 

Содержание PowerVu D9858

Страница 1: ...Cisco D9858 Advanced Receiver Transcoder Software Version 4 50 Installation and Configuration Guide ...

Страница 2: ...nstaller ou d utiliser ce produit Prêtez une attention particulière à toutes les règles de sécurité Zu beachten Bitte lesen Sie vor Aufstellen oder Inbetriebnahme des Gerätes dieses Handbuch in seiner Gesamtheit durch Achten Sie dabei besonders auf die Sicherheitshinweise Importante Sírvase leer la presente guía antes de instalar o emplear este producto Preste especial atención a todos los avisos ...

Страница 3: ...ems Inc assumes no responsibility for errors or omissions that may appear in this publication We reserve the right to change this publication at any time without notice This document is not to be construed as conferring by implication estoppel or otherwise any license or right under any copyright or patent whether or not the use of any information in this document employs an invention claimed in a...

Страница 4: ...CODE AVC VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL AND NON COMMERCIAL ACTIVITY AND OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO PROVIDE AVC VIDEO NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA L L C SEE HTTP WWW MPEGLA COM Accordingly please be advised that service providers content providers and broadcasters ar...

Страница 5: ...that is meant for uninterrupted service and that for some specific reason such as the possibility of the loss of an authorization code for a CATV converter is not intended to be unplugged by the user for cleaning or any other purpose may exclude the reference to unplugging the product in the cleaning description above 6 Attachments Do not use attachments not recommended by the product manufacturer...

Страница 6: ...ower supply to your home consult your product dealer or local power company For products intended to operate from battery power or other sources refer to the operating instructions 11 Grounding or Polarization This product may be equipped with a polarized alternating current line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safet...

Страница 7: ...n to grounding electrodes and requirements for the grounding electrode 15 Lightning For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges 16 Power Lines An outside antenna ...

Страница 8: ...has used replacement parts specified by the manufacturer or have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards 22 Safety Check Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition 23 Wall or Ceiling Mou...

Страница 9: ...s may have to be disconnected before servicing This product plugs into a socket outlet The socket outlet must be near this product and must be easily accessible Connect this product only to the power source that is indicated on the rear panel of this product If this product does not have a mains power switch the power cord serves this purpose Enclosure Do not allow moisture to enter this product D...

Страница 10: ...oduit Il indique une borne sous tension la direction indique la borne Ce symbole peut être attaché à ce produit Il indique une borne de terre de protection Ce symbole peut être attaché à ce produit Il indique une température excessive ou dangereuse Alimentation Important Ce produit fait partie de la classe I Vous devez le mettre à la terre Ce produit se branche dans une prise murale Cette dernière...

Страница 11: ...voll verstanden haben Dieses Symbol erscheint auf dem Gerät und oder in der ihm beiliegenden Literatur Es bedeutet wichtige zu beachtende Betriebs oder Wartungsanweisungen Wenn dieses Zeichen am Gerät angebracht ist warnt es vor einer spannungsführenden Stelle Dieses Symbol kennzeichnet auf dem Gerät die Anschlußstelle der Sicherheitserde Wenn dieses Zeichen am Gerät angebracht ist warnt es vor he...

Страница 12: ...ite dañar el producto No avance más allá de cualquier símbolo hasta comprender completamente las condiciones indicadas Encontrará este símbolo en el impreso que acompaña a este producto Este símbolo indica instrucciones importantes de funcionamiento o mantenimiento Es posible que este símbolo esté pegado al producto Este símbolo indica un terminal vivo la flecha apunta hacia el aparato terminal Po...

Страница 13: ...licati al prodotto Se circostanze avverse compromettono la sicurezza d uso di questo prodotto interrompetene l uso e assicuratevi che il prodotto non venga più utilizzato Evitare infortuni alla persona e danni al prodotto Non procedere oltre a qualunque simbolo fino a quando non si siano comprese pienamente le condizioni indicate Questo simbolo che appare nella letteratura di accompagnamento del p...

Страница 14: ... aprire la chiusura di questo prodotto a meno che non sia specificato diversamente Non inserire oggetti attraverso le fessure della chiusura Cavi Staccare sempre tutti i cavi di alimentazione prima di svolgere l assistenza tecnica al prodotto Per scollegare un cavo tirate la spina o il connettore non tirare mai il cavo stesso Non calpestare o sottoporre a sollecitazioni i cavi o le prese Riparazio...

Страница 15: ...cal Settings 7 Uplink Profile Settings 9 NIT Retune Recovery 10 Chapter 2 Quick Setup Read Me First 11 Connecting the Transcoder to Other Equipment 12 Maintenance of EMC Compliance 12 Setting up for Network Connection 13 Quick Setup Instructions for RF Acquisition 14 Assigning a Program Channel to a PE Program Entry 15 Setting up the ASI Output 16 Setting the DPM Mode 17 Chapter 3 Installation 19 ...

Страница 16: ...t SSH Connection 30 Administrator User Privileges 30 Starting a Telnet SSH Session 30 Adding a New User 31 Deleting a User 31 Changing a Username 31 Changing a Password allowed by all Users 32 Printing the List of Users 32 Resetting the Login Credentials 32 Chapter 4 Front Panel Operation 33 About the Front Panel 34 LCD 34 Keypad 34 Front Panel LEDs 34 Navigation Selection Keypad 35 Locking Unlock...

Страница 17: ... 134 Power On 134 Health Monitor 135 Chapter 5 Web GUI Setup and Monitoring 137 Logging On to the Web GUI 138 D9858 Summary Overview 139 Shortcuts 139 Modules 139 Alarms Warnings 140 D9858 Menus 142 D9858 Web GUI Environment 144 Window Buttons 144 Setting up Input Information 145 Setting up the RF Input 145 Setting up the ASI Input 150 Setting up SI Receive Parameters 152 Setting up Muting Thresho...

Страница 18: ...tal Program Mapping DPM 219 Setting up Default Settings for the Transcoder 221 Configuring System Settings 228 Viewing the System Identification 228 Viewing Hardware Features and Base License Information 229 Setting up IP Information 230 Setting up IP Routing Information 234 Configuring the MPE Settings 236 Setting up SNMP Information and Trap Destinations 238 Configuring Time Clock Settings 240 V...

Страница 19: ... Outputs and Processing 336 General 336 Video Inputs 336 Video Outputs 336 Audio Inputs Outputs 339 VBI Data Input Output 340 Transport Stream Outputs 341 ASI Output 341 MPEGoIP Output 341 MPE Output 341 Control Management and Data Interfaces 343 Ethernet Management Interface 343 Ethernet Data Interface 343 RS 232 Data Interface 343 Alarm Interface 343 Contact Closure Interface 344 Power and Gener...

Страница 20: ...6 Transcode Menu 357 Inband 358 Options 358 Alarm Warning 359 Noise Cutoff 359 Import Export Web GUI only 360 DPM Default Settings for Different Output Modes 361 Appendix C Compliance 365 Applicable Standards and Notices 366 Safety 366 ESD 366 Electromagnetic Compatibility Regulatory Requirements 366 FCC Notices 367 Industry Canada Notice 367 Unauthorized Modifications 367 Declaration of Conformit...

Страница 21: ...des users operators and service personnel who are responsible for the installation configuration operation monitoring and service of the D9858 transcoder RequiredKnowledge To use this documentation the user should have a basic knowledge of the technology used in relation to this product Service personnel should have additional skills and be familiar with cabling electronic circuitry and wiring pra...

Страница 22: ......

Страница 23: ...sco D9858 Advanced Receiver Transcoder It describes the most common applications and interfaces of the transcoder 1 Chapter 1 Introduction In This Chapter D9858 Advanced Receiver Transcoder 2 Transport Stream Outputs 5 Disaster Recovery 7 NIT Retune Recovery 10 ...

Страница 24: ...ion This helps distribute the compressed video programs efficiently to subscribers equipped with digital set top boxes Digital Program Insertion DPI information is also be available along with the video and audio PIDs Packet Identifiers for external ad insertion in compressed digital format Digital audio passthrough is synchronized to the transcoded program output Compliant Program Specific Inform...

Страница 25: ...m monitoring Simple Network Management Protocol SNMP for setup control and monitoring Field upgradeable software Front panel liquid crystal display LCD for control and monitoring Web browser interface for easy setup control and monitoring Uplink addressable decoder output control including vertical blanking interval VBI data audio routing DPI and ASI output Dual tone multifrequency DTMF cue tone a...

Страница 26: ... Update All software in the D9858 transcoder is stored in non volatile memory that can be electrically programmed New software releases for the D9858 transcoder can be downloaded via the Ethernet 10 100 1000BASE T Management interface ...

Страница 27: ...tly distributed to households equipped with digital set top boxes Digital Program Insertion DPI information will also be available along with the video and audio PIDs Packet Identifiers for external ad insertion in compressed digital format The diagram below shows an example of the D9858 transcoder used in an ASI or MPEGoIP application MPEOutput The Multiprotocol Encapsulation MPE output provides ...

Страница 28: ...Chapter 1 Introduction 6 The diagram below shows an example of the D9858 transcoder used in an MPE application ...

Страница 29: ... after the configured signal loss timeout it will initiate a disaster recovery search based on the search pathdetermined by the disaster recovery configuration A DR symbol is displayed on the front panel and the D9858 web GUI displays a D R in progress status During a disaster the receiver will attempt to tune to a different backup transport based on the search path configured The origin transport...

Страница 30: ...1 to channel 101 but leave PE2 to channel 2 because PE2 is not specified for Backup 2 transport If the acquisition fails or there is no signal lock on the backup 2 transport it will continue the search path and set PE1 to channel 801 and PE2 to channel 1005 if the acquisition is successful on the backup 3 transport However if the acquisition fails or there is no signal lock on the backup 3 transpo...

Страница 31: ... is not connected to the PNC uplink an error message is triggered and it will use the local disaster recovery settings if enabled During a disaster recovery the PNC sends the Disaster Recovery Table DRT to the receiver along with the backup locations The DRT is a table of data structures sent from the PNC to the unit through the satellite uplink For more information on the uplink disaster recovery...

Страница 32: ...nate between the new signal and the original signal for up to one hour If the unit does not lock to a signal after one hour it will trigger a disaster recovery The unit must stay locked to the new signal NIT for a minimum of ten minutes If another NIT is received before the ten minute timer the ten minute timer is canceled the initial engagement delay period for the next NIT retune resets back to ...

Страница 33: ...to use contact your local service provider for assistance 2 Chapter 2 Quick Setup Read Me First In This Chapter Connecting the Transcoder to Other Equipment 12 Setting up for Network Connection 13 Quick Setup Instructions for RF Acquisition 14 Assigning a Program Channel to a PE Program Entry 15 Setting up the ASI Output 16 Setting the DPM Mode 17 ...

Страница 34: ...he messages Application Starting will appear on the front panel The boot up process will take approximately 1 minute for the unit to initialize When ready the front panel display shows the start up screen The power cord consisting of appliance coupler flexible cord and plug supplied with this product meets the requirements for use in the country for which this product was purchased In general the ...

Страница 35: ... to select the IP menu Press SELECT twice to go to the IP menu 3 Use the arrow keys to navigate up and down the IP menu and the arrow keys to move across the IP menu to set the IP Address Mask and Gateway parameters Use the number keys to directly enter numbers in the fields For more information on keypad operation see Keypad Convention 4 Press SELECT each time to save the changes Press MENU four ...

Страница 36: ...e Sym Rate menu Press SELECT Enter the symbol rate Press SELECT If DVB S2 is used proceed to Step 9 If DVB S is used press to set up the FEC Press SELECT Use to select AUTO Press SELECT 9 Press twice to move to the Net ID menu Press to choose Net ID Press SELECT Enter the value Press SELECT 10 Press Press SELECT Use to change the LNB power if needed Only the RF1 port is capable of providing 13V or...

Страница 37: ... D9858 is available in a single channel D9858 1 ora dual channel configuration The single channel transcoder D9858 1 supports one Program Entry PE1 only 3 Press ADV again to select the channel number 4 Use the keys to scroll through the available program channels or directly enter the channel number using the 0 to 9 keys press SELECT to save the channel selection Note Enter 0 to remove the program...

Страница 38: ...u Press Press SELECT Use to select the output mode The factory default is No Output We recommend to set the Output Mode to Transcoding 6 Press SELECT Press to select Yes if requested to RESYNC ALL Press SELECT 7 Press to move to Descramble Mode menu Press SELECT Use to select the scrambling mode Press SELECT 8 Press to move to Insert Null Packet Press SELECT Use to change the mode to Yes Press SEL...

Страница 39: ...ings defined for the transcode channel 1 Press MENU to display the Main Menu 2 Press to move to the Setup menu Press SELECT 3 Press four times to move to the Outputs menu Press SELECT 4 Press to move to the TS Out menu Press SELECT 5 Press twice to move to the DPM menu Press SELECT 6 Press SELECT to access the Global menu 7 Press SELECT to choose ASI for Resync All Press and then press SELECT to c...

Страница 40: ......

Страница 41: ... operate or maintain the D9858 receiver WARNING Allow only authorized and qualified service personnel to install operate maintain and service this product Otherwise personal injury or equipment damage may occur 3 Chapter 3 Installation In This Chapter Power Connection 20 Installing the D9858 Transcoder 21 Rear Connector Panel 23 Connecting the Input Output Signals 25 Setting Admin User Privileges ...

Страница 42: ... some products do not have a power switch In this case the main cord and or DC power supply cable serve s as the main disconnect device WARNING Make sure that at least one end of the power cable s remains easily accessible for unplugging if you need to switch off the unit For example ensure that the socket outlet is installed near the product WARNING To avoid electrical shock connect the three pro...

Страница 43: ... exceed 50 C 122 F at any time Grounding You must ensure that the unit is properly connected to ground to meet safety and EMC requirements Before any other connection is made the unit must be connected to a protected ground terminal as described below Via the three wire power cord of the AC power supply This connection is mandatory In addition via the protective ground terminal on the rear panel o...

Страница 44: ...0 200 to 240 V AC power outlet 2 Make sure that the power cable is connected to protective ground See Grounding on page 21 for more information The D9858 transcoder is equipped with one power supply located in the rear of the chassis Note the location of the power supply in the event of alarms warnings resulting in replacement of a power supply Alarm messages appear in the Message Log ...

Страница 45: ...Output This is for the MPEGoIP and MPE outputs The MPEGoIP output of the transport stream is encapsulated in the IP packets to a groomer for distribution The MPE output receives IP packets from the transport stream RJ 45 Management Supports the following network protocols Telnet SSHv2 HTTP HTTPS SNMPv2 Syslog DTX SNTP FTP client side MPEGoIP output and TFTP RJ 45 Cue Tone Cue Trigger Relay Outputs...

Страница 46: ... 1 and CVBS 2 provide two identical SD composite video outputs for monitoring applications BNC Balanced Audio Outputs Audio 1 and Audio 2 provide two stereo pairs or four mono channels Terminal Blocks Ground Screw Grounding point for the transcoder Power AC power IEC 60320 Sheet 14 ...

Страница 47: ...onous serial interface for uplink monitoring ConnectingtheVideo Outputs Connector for the Video Output The video output connectors are of the BNC type Connecting the Composite Video Output Connect a video monitor to the CVSB 1 and CVSB 2 connectors The two outputs are identical Use a 75 ohm double braided coax cable ConnectingtheBalanced AudioOutput 1 Connect the AUDIO 1 and AUDIO 2 balanced audio...

Страница 48: ...on the D9858 transcoder and the Ethernet port of your PC Note You need a crossover cable if you want to connect the Ethernet interface of the D9858 transcoder directly to another Ethernet device without using a hub or switch Set up the IP address on the D9858 transcoder via the front panel display For information on setting up the IP address via the front panel see IP on page 70 ConnectingtheIP TS...

Страница 49: ...up Menu on the front panel The Alarm output connector is a 15 pin sub D female connector The diagram below shows the connector and the pin allocation table for the Alarm output pins The connector pin states depend on the selected Relay Mode The Relay Mode is set on the front panel For more information see Cueing on page 89 Changing the Relay Mode for Alarm Monitoring The Alarm relay is a program r...

Страница 50: ...ta interface and a female DB 9 connector to connect to the PC RS 232 Data Connector Pin Allocation The table shows the RS 232 Data connector and the pin allocation Connector Normally closed pin Common pin 1 9 1 Not connected 2 TxD 3 RxD 4 Not connected 5 Ground 6 Not connected 7 Not connected 8 Not connected 9 Not connected ConnectingtheCue Tone CueTrigger Interface The D9858 transcoder is equippe...

Страница 51: ...Cue Trigger pins 1 to 8 to up to 8 serial control devices or a device to control ad insertion These outputs are user configurable on the front panel menu ConfiguringOpen collector Outputs The D9858 supports decoding of SCTE 35 messages with DTMF descriptor The D9858 outputs tones or sets the open collector contacts according to the content of the DTMF descriptor in the Cisco D9054 HDTV Encoder and...

Страница 52: ...ation session with the transcoder use a utility such as Tera Term Pro or PuTTY Proceed as follows to log into a new connection using Tera Term 1 In the New Connection window enter the IP address in the Host field 2 If you want to start a telnet session select Telnet and enter 23 in the TCP Port field 3 If you want to start an SSH session select SSH and enter 22 in the TCP Port field 4 Click OK 5 I...

Страница 53: ... Front Panel 4 At the CONFIRM NEW PASSWORD prompt type the new password again and press Enter Note The New Password and Confirm New Password should be identical 5 At the NEW USER PRIVILEGES prompt enter the type of account you want to assign the user The following table illustrates the different login types Account Type Enter Access Guest 3 View settings only User 2 View and edit settings Admin 1 ...

Страница 54: ... Each user including the admin user can modify only his own password Printing theListof Users At the admin prompt type pwd list_users and press Enter Note Only usernames will be printed Passwords will not be visible Resetting theLoginCredentials At any time the user authentication table can be reset from the front panel This option is under the Setup IP IP menu Scroll down to Reset Credentials and...

Страница 55: ...anel keys and display This information is primarily applicable for standalone operation 4 Chapter 4 Front Panel Operation In This Chapter About the Front Panel 34 Locking Unlocking the Front Panel 38 Startup Screen 39 Main Menu 43 Status Menu 44 Setup Menu 57 About Menu 127 Versions Menu 129 Diagnostics Menu 132 ...

Страница 56: ... parameter values available using the navigation selection keypad The items are selected by pressing the SELECT center key or the down arrow key on the navigation selection keypad Keypad The numeric keypad is used to enter alphanumeric values The MENU key sets the software to the initial menu and returns to the previous menu The MENU key can also be used to cancel a numeric entry at any point duri...

Страница 57: ...Keypad Throughout this manual there are references to parts of a keypad on the front of the receiver The navigation keys LEFT RIGHT UP and DOWN and the SELECT key are the primary controllers Each navigation key performs various functions depending on the current state of the menu system that is sometimes the left navigation key backspaces over an entry and sometimes moves the cursor to a different...

Страница 58: ... Arrow key Highlights the menu item above DOWN Arrow key Highlights the menu item below SELECT key Runs the highlighted command or opens the highlighted menu INFO key Press the key on the lower left of the numeric keypad for context sensitive help messages when available When entering characters in numeric or alphanumeric fields this key can be used to toggle between uppercase and lowercase MENU k...

Страница 59: ... Repeatedly pressing the button will toggle through all of the key s possible choices When entering text the 1 button can be used to insert spaces press twice To delete a character press 0 twice ADV Toggles between Program Entry and Channel number MAP Edit insert and delete Digital Program Mapping DPM Modes on Program Entries or on PIDS within Program Entries APPLY Activates current changes withou...

Страница 60: ... unless you change the keypad state on the Admin Menu Likewise you can toggle the keypad lock state back using SELECT and INFO at any time provided the KB Lock state on the Admin Menu is Enabled For more information on front panel keypad buttons see Keypad Convention Note If the lock level is 3 or 4 you must enter a password to unlock the front panel For more information on lock level password see...

Страница 61: ...authorized N Indicates the channel is not authorized LCD Panel The LCD panel displays basic signal and program information in the LCD display as described in the following illustration LCD Setting Description PE Program Entry The D9858 is available in a single channel D9858 1 or a dual channel configuration The single channel transcoder D9858 1 supports one Program Entry PE1 only The dual channel ...

Страница 62: ...information are operating as expected LCD Symbol Various symbols will periodically appear in the top right hand corner of the LCD panel indicating which user actions are currently acceptable The following displays the location of the symbol The following table describes the various symbols LCD Symbol Description The Hourglass indicates that parameters are being saved in the background You can cont...

Страница 63: ...oftware is ready for download but a download trigger by the transcoder is required before it will be downloaded Note Service interruption occurs during a reboot which is always required when the software is updated The Download symbol indicates that a software download for a version of software already in memory has been detected The Disaster Recovery DR symbol indicates that a disaster is declare...

Страница 64: ... Lvl 50 Marg 11 6 Ch 5 Directly enter the channel number using the 0 to 9 keys and press SELECT to apply the channel number or press to scroll through the available channels Deleting aProgram from theProgram Entry To delete a program from the PE 1 Press MENU until the startup screen appears s PE1 706 Channel Name RF1 Freq 12 658 Lvl 50 Marg 11 6 Ch PE The PE channel is displayed Note PE1 is the de...

Страница 65: ...Setup About Versions i s Main Menu 2 2 Diagnostics i s Select the desired function by moving the cursor left or right by pressing the LEFT or RIGHT arrow key Once a selection is made by pressing the SELECT key the LCD presents the second menu level for the selected function Succeeding levels for each function include all the hierarchical levels for the function in the front panel LCD ...

Страница 66: ...utput signals the video and audio services and allows you to browse and or configure the alarms and warnings The Status menu is split into four parts General Services TS Input and TS Output Each parameter is described in this section For instructions on how to select and store settings see About the Front Panel on page 34 The Status menu has the following structure ...

Страница 67: ... to view PE1 or PE2 Note The single channel transcoder D9858 1 supports one Program Entry PE1 only Mode Indicates how the program is scrambled Unkn DES DVB BISS1 BISS2 or BISS3 Auth Indicates whether the receiver is authorized to receive the program Yes or No Enc Indicates whether the received program is encrypted Yes or No Scr Indicates whether the received program is scrambled Yes or No CA Syste...

Страница 68: ... available Otherwise the current TDT date and time is displayed Note This is displayed as local time Current TDT Date and Time Displays the current TDT Time and Date Table date and time received from the DVB stream Note This is displayed as local time Current SNTP Date and Time Displays the current SNTP Simple Networking Time Protocol date and time if IRD receives a valid reply from the NTP server...

Страница 69: ...io channel Aud1 AUD2 for audio channel Aud2 AUD1 to AUD4 for two stereo audio channels Format Indicates the format of the audio input stream None Sine Pink Beep MPEG1L1 MPEG1L2 MPEG2L1 MPEG2L2 AC3 LOAS AAC ADTS AAC LOAS HEAAC ADTS HEAAC or DDP BR Kbps Indicates the bit rate of the audio input stream in kbps Buffer Indicates the buffer level of the input audio stream in bytes SFR kHz Indicates the ...

Страница 70: ...ymbols second FEC Indicates the FEC Forward Error Correction rate of the received signal N A 1 2 3 5 2 3 3 4 4 5 5 6 7 8 8 9 or 9 10 Modulation Indicates the modulation type for the received signal N A QPSK 8PSK DVB S DVB S2 or 16QAM Pol Indicates the signal polarization setting This setting is only applicable when LNB Power is set to H NIT or V NIT The selected setting must match the polarization...

Страница 71: ...2 PVBER Indicates the PV Post Viterbi BER for the received signal DVB S LDPCBER Indicates the LDPC Low Density Parity Check error rate for the received signal DVB S2 AFC MHz Indicates the current Automatic Frequency Control count in MHz UEC Indicates the current Uncorrected Error Count for the received signal CEC Indicates the current Corrected Error Count for the received signal DVB S Clear Count...

Страница 72: ...Power supply Off 13V or 18V LO Select Indicates whether a 22 kHz tone is available on input port RF1 This is applicable for dual band applications On or Off Program PIDs Menu Item Description Parameters PE Select the Program Entry to view PE1 to PE2 Note The single channel transcoder D9858 1 supports one Program Entry PE1 only Stream Indicates the name assigned to the Program Entry Up to 4 alphanu...

Страница 73: ...rized to view the primary program This is an uplink initiated function that maps the alternate service to the original primary service PIDs replacing the original service with the alternate service at the digital transport output No local intervention is required by the receiver operator for provision of this service replacement feature Not Started Indicates that an event has not started Primary I...

Страница 74: ...icates that only transcoders authorized by the Cue Trigger mask will tune to the scheduled program event Note The Cue Trigger service replacement event type is not supported in the current release SR Event Start Displays the start time of the service replacement event when one is scheduled otherwise the default start time is displayed The default start time is 2007 09 01 00 00 00 SR Event End Disp...

Страница 75: ...ssover Port 1 is the management port and port 2 is the data port Redundancy Status The D9858 transcoder is a single port unit The Redundancy Status section is not supported Global Status Menu Item Description Parameters Engine Error This is not supported Stream Overflow Indicates the MPEG over IP transport stream overflow status Yes or No Combined User Rate Displays the configured output bit rate ...

Страница 76: ...is higher than the configured output bit rate Yes or No Link Overflow Indicates if the configured output bit rate is close or higher than the current Ethernet link speed for the Ethernet port used for MPEGoIP output Yes or No Status Menu DR To view the DR Disaster Recovery menu from the Status menu press the RIGHT arrow key five times The DR menu provides the current disaster recovery status infor...

Страница 77: ...very in progress Goto RF n OK FAIL No Action Goto Backup n OK FAIL No Action Goto Origin OK FAIL No Action Goto Preferred RF OK FAIL No Action Configured By Displays the current disaster recovery setting User The unit is using the disaster recovery settings configured locally Uplink The unit is using the PNC disaster recovery profile User or Uplink Signal Loss Timer Indicates the time in seconds t...

Страница 78: ...ser it displays the time set by the local unit If the Profile is set to Uplink it displays the time set by the PNC uplink But if the unit is not connected to the uplink the default value of the unit is displayed 10 to 255 Backup Channel Status Menu Item Description Parameters PE Displays the program entry PE1 or PE2 Backup Channel Displays the channel number assigned to the selected backup transpo...

Страница 79: ...lock level password factory reset keypad lock download mode and date and time TS Input frequency parameters for acquiring and locking on to an RF signal or receiving an ASI input IP parameters for setting up the Ethernet ports Services audio video captions and VBI Outputs alarm relays cue tone cue trigger setup parameters for setting up the transport stream out which includes DPM and transcoding C...

Страница 80: ...ructions on how to select and store settings see About the Front Panel on page 34 The Admin menu has the following structure Menu Item Description Parameters Lock Level Sets the front panel interface lock level For information on each of the lock levels see Appendix B Default Settings and Lock Levels on page 347 0 1 2 3 or 4 ...

Страница 81: ...tings back to the factory set default values A warning message prompts you to confirm the operation Reboots Unit you are prompted to verify the operation Abort or Continue Clear FWD tables Select to clear settings that are only used in older applications Reverting back to an older application will revet to the default values of the cleared settings A warning message prompts you to confirm the oper...

Страница 82: ...nterruption will occur Limit Version Indicates the oldest version of the application that can be installed on the current unit Older applications will not be installed Read only alphanumeric value DL Status Indicates the current download state Init Download component is being initialized You cannot perform a download while in this state Ready Download component is ready to receive downloads Buffer...

Страница 83: ...for app7109 on the main board FPGA 7109 Currently downloading FPGA code to the main board Note The FPGA download does not occur over the air Sat 7109 Currently downloading SAT7109 code to the transcoder board App PPC Currently downloading code to the application in the PowerPC on the transcoder board PowerPC Currently downloading code such as FPGA or VASA to the PowerPC on the transcoder board CDT...

Страница 84: ...e download does not resume from where it was aborted but restarts from the beginning None No action is to be performed Date Format Select the date format YYYY_MM_DD DD_MM_YYYY or MM_DD_YYYY Time Format Select the time format 24Hr 24Hr SuspendZero 12Hr 12Hr SuspendZero The SuspendZero options omit the leading zero GMT Off Select the local time zone offset relative to the GMT time The time informati...

Страница 85: ...e RIGHT arrow key once and the SELECT key to view the TS Input menu For instructions on how to select and store settings see About the Front Panel on page 34 The TS Input menu has the following structure ASI Input Menu Item Description Parameters ASI Active Select whether to tune to the ASI input Note Setting a new input to be active will deactivate the currently active input Act or No ...

Страница 86: ...rvices in the program that are not scrambled will still be available RF1 RF2 RF3 RF4 RFx Input Menu Item Description Parameters RFx Active RF1 RF2 RF3 RF4 Select the input to be active Note Setting a new input to be active will deactivate the currently active input Act or No Tune Mode Select which tables are required for the service list creation and signal acquisition Note When editing the tuning...

Страница 87: ...e value for LO2 LO2 GHz Sets the higher oscillator frequency in GHz of the LNB In a single band oscillator set this value to 0 0 0 0 to 15 0 GHz Must be higher than the value for LO1 Crossover GHz This is the crossover frequency which is an internal threshold frequency used for selecting the LO1 or LO2 frequency depending on the current Downlink frequency settings This option is only used in dual ...

Страница 88: ...nnected to this RF input H horizontal Vert vertical A Auto Auto is only applicable when LNB Power is set to H NIT or V NIT Validate Orbital Position This option allows you to configure and validate the RF inputs to match those expected by the network The transcoder will check to see if all the frequencies in the Network Information Table NIT can be tuned to Orbital Position Validation Date This di...

Страница 89: ...elect the Input signal spectrum inversion setting which allows the operator to track and select inverted and non inverted digital signals This is normally used to automatically reject or filter out unwanted signals Auto Normal or Opposite Auto The signal is tracked and inverted for correct selection as required Opposite The signal is always inverted Normal The signal is not inverted NetID Select t...

Страница 90: ...ny service list table to be present to acquire the signal BAT This is not supported in the current release No NIT If using custom tune mode select whether to use the Network Information Table NIT when creating the service list Yes or No SDT If using custom tune mode select whether to use the Service Description Table SDT when creating the service list Yes or No PAT If using custom tune mode select...

Страница 91: ...No Frequency Tuning Indicates whether tuning is using the NIT to tune to other transports or whether tuning is forced to use the user selected parameters NIT or User Cfg Re Acquire Menu Item Description Parameters Re Acquire Re acquires the signal using the tuning parameters from user settings Abort or Continue Select Abort to cancel the operation or choose Continue to complete the operation Setup...

Страница 92: ...onfigure 1 or 2 Interface 1 is the control and management interface and interface 2 is the data interface Description Sets the description or name for the Ethernet interface Up to 20 alphanumeric characters in length V4 V6 Select the IP protocol Only IPv4 is currently supported IP Address Sets the IPv4 IP address for the interface 12 digits in length Mask Sets the number of CIDR Classless Inter Do...

Страница 93: ...D full duplex 100 HD 100 FD or 1000 FD to lock into a fixed mode Auto default 1000FD full duplex 100HD half duplex 10FD 100FD or 10HD MAC Address Displays the MAC address of the interface It is set at the factory and is a read only value N A SNMP Read Only Community String Sets the password to read data from a device and to display diagnostics traps alarms This is used when communicating with a de...

Страница 94: ...es via a Telnet SSH Connection on page 30 Note After this recovery procedure all existing user accounts will be lost Password Complexity Sets the password complexity for all users The complexity level changes will only affect the new user accounts and password changes It will not affect existing accounts No Checking Minimal Checking or Full Complexity Checking For more information see the Password...

Страница 95: ...o letter is repeated more than three times in a row Must contain a minimum of eight characters Must contain a minimum of three of the following types of characters capital letters small letters digits and special characters Traps Menu Item Description Parameters Trap IP Address Sets the destination IP address for SNMP trap messages for system events for example fault messages Up to 12 digits in le...

Страница 96: ...r HTTP TCP port 443 for HTTPS Disable Disables the listener for the HTTP port Enable default Allow web connections Secure Encrypted access to the webserver HTTPS For more information see Protocol Control Settings on page 231 SNMP Controls SNMP access to the IRD Select Enable to allow SNMP connections Select Disable to disable the listener for the SNMP port UDP port 161 Enable default or Disable MP...

Страница 97: ... services are Telnet SSH and HTTP The examples of UDP based services are SNTP and SNMP Proceed as follows to obtain TCP or UDP information 1 Start a new communication session with the receiver using a utility such as Tera Term Pro or PuTTY For more information on starting a new connection see Starting a Telnet SSH Session on page 30 2 In the D9858 command prompt type ipal tcp_list for a list of TC...

Страница 98: ...nce and then the SELECT key to reach the Setup menu Then press the RIGHT arrow key three times and the SELECT key to view the Services menu The Services menu allows you to set up all the operating parameters associated with audio video and captions services Each parameter is described below The menu has the following structure ...

Страница 99: ...f any enabled alarm is active on the receiver When video is cut off there will be no horizontal or vertical synchronization on the output This is useful for downstream redundancy switching by detecting a loss of video signal Note This same function also exists under Setup Alarm Warning Enable or Disable The default is Disable OSD Messages Sets whether alarms and warnings are to be displayed on the...

Страница 100: ...ow the receiver affects PAL WSS when it is present in the VBI line 23 Auto Create Creates WSS to output the correct aspect ratio when performing aspect ratio conversion Auto Modify If WSS is present in the input stream it is modified to output the correct aspect ratio when performing aspect ratio conversion If WSS is not present in the input no WSS will be present in the output Suppress Removes WS...

Страница 101: ... Normal picture 4 3 4 3 4 3 CCO None Conversion is not possible Normal picture 4 3 4 3 4 3 P B None Conversion is not possible Normal picture 4 3 4 3 14 9 None Conversion is not possible Normal picture 4 3 4 3 16 9 SCALE None Conversion is not possible Normal picture 4 3 16 9 None None Picture is short and wide 4 3 16 9 Auto 4 3 P B Uses 4 3 P B 4 3 16 9 16 9 L B None Conversion is not possible Pi...

Страница 102: ...of the 4 3 picture and crops the top and bottom of the screen 16 9 16 9 None None Normal 16 9 16 9 Auto None No conversion Normal picture 16 9 16 9 16 9 L B None Conversion is not possible Normal picture 16 9 16 9 4 3 CCO None Conversion is not possible Normal picture 16 9 16 9 4 3 P B None Conversion is not possible Normal picture 16 9 16 9 14 9 None Conversion is not possible Normal picture 16 9...

Страница 103: ...ve Format Descriptor AFD normally it is necessary to set both the TV Aspect Ratio and Conversion to correctly display the video program on the TV system The Auto AFD option enables the receiver output to automatically match the display format of the video program to the TV system based on specific uplink program information carried in the transport stream In this case the receiver performs the con...

Страница 104: ...stment for the Left audio channel in dB 6 0 to 6 0 Any value can be entered with the numeric keypad in the appropriate range but the UP and DOWN arrows will increase or decrease in 0 5 dB steps Right dB Sets the volume adjustment for the Right audio channel in dB 6 0 to 6 0 Any value can be entered with the numeric keypad in the appropriate range but the UP and DOWN arrows will increase or decreas...

Страница 105: ...ie Vietnamese PMT Src Selects the PMT source for the audio channel None AUDI to AUD64 Entry If Select Language By is set to Language Entry select the language entry for the selected audio Enter a three character code provided by your uplink service provider under Entry using the numeric keypad for example eng for English The supported languages are according to ISO 639 2 Language Codes Captions Me...

Страница 106: ...onversion If WSS is not present in the input no WSS will be present in the output Suppress Removes WSS output Passthrough Passes WSS unmodified as received by the receiver The default is Passthrough WSS Stat This indicates the current output value of PAL WSS in VBI line 23 4 3 F F 16 9 L B CEN 16 9 L B TOP 16 9 L B 14 9 L B CEN 14 9 L B TOP 14 9 F F CEN 16 9 F F or UNDEFINED Note F F is full forma...

Страница 107: ...Language Entry Allows you to enter a language code PMT Order Allows you to select a PMT order The default setting is Language List Language Entry and PMT Order are more applicable for advanced applications Language List If Language List was selected in the Select Language By menu select the MPEG language to display ara Arabic btk Batak Indonesia ben Bengali bul Bulgarian chi Chinese cze Czech dan ...

Страница 108: ...es are according to ISO 639 2 Language Codes Imitext Position Sets the position of the on screen subtitle text Standard or Extended ForeGnd Sets the text color for Imitext subtitles Auto Yellow or White Auto displays text in the color transmitted by the subtitling equipment Yellow and White override the color set by the uplink and display text in the selected color BackGnd Sets the text background...

Страница 109: ...e Note By default all the decode services are enabled Video Audio1 to Audio4 VBI Vertical Blanking Interval DATA low speed data MPE1 to MPE5 Multiprotocol Encapsulation STT Subtitles or DPI Digital Program Insertion Enabled Select whether the local decoding of this service is enabled or disabled Yes or No ...

Страница 110: ...he RIGHT arrow key four times and the SELECT key to view the Outputs menu The Outputs menu allows you to set up the rear panel control relays for alarms cue tones and cue triggers and the transport stream outputs Digital Program Mapping DPM and Transcoding For instructions on how to select and store settings see About the Front Panel on page 34 The Outputs menu has the following structure ...

Страница 111: ...und on an active cueing signal and as open or floating collectors on an inactive signal Repeat If the Cueing Mode was set to Tone set the number of consecutive tone sequences to be generated Values greater than 1 are provided when a scenario demands repetition to ensure that the ad insertion equipment receives the signal 1 2 or 3 The default is 3 Tone ms If the Cueing Mode was set to Tone set the ...

Страница 112: ... at the Cue Tone Relay output on the rear panel of the receiver Alarm or Trigger The following table displays the possible field settings and their relationship to the receiver output Relay Mode Condition Relay Contact NC C C No Alarm Unit Power Off Open Close Alarm State Open Close No Alarm Close Open Trigger Active selected in PNC Close Open Inactive Open Close Cue Trigger Bit If the Relay Mode ...

Страница 113: ...ated and in most cases it will be lower than the overall input rate User The output rate is specified by the User Rate Mbps parameter It is determined by the user setting regardless of the input source Null packets are always inserted when the configured output bit rate is higher than the payload rate of the transport stream to be encapsulated User Rate Mbps If the Rate Control is set to User set ...

Страница 114: ...Passthrough the option to re sync will be provided If you select Yes it will set the DPM mapping to the last valid or saved configuration If you select No it will use the existing DPM maps If the PE is mapped it uses the last saved output MAP configuration The output map for example output channel PMT does not change automatically if the input or channel number is changed MAP Svc Chans Only This i...

Страница 115: ...led even if the PE is authorized and can descramble the channel Descrambled Descrambles the output channel and passes in the clear channels The default is Descrambled Insert Null Packet Select whether to insert null packets into the output to maintain output at a constant bit rate Yes or No Note We recommend that you set the Insert Null Packet to Yes especially if the Output Mode is set to Transco...

Страница 116: ... transport output for ease of reference 20 character string Rate Control This is the DPM output rate control Auto The output rate follows that set by the uplink This setting can be used if the signal source is ASI If Insert Null Packet is set to Yes the output bit rate is the same as the input rate including all the null packets If Insert Null Packet is set to No the output rate is equal to the pa...

Страница 117: ...gh the option to re sync will be provided If you select Yes it will set the DPM mapping to the last valid or saved configuration If you select No it will use the existing DPM maps If the PE is mapped it uses the last saved output MAP configuration The output map for example output channel PMT does not change automatically if the input or channel number is changed MAP Svc Chans Only This is similar...

Страница 118: ...lways inserted if the Rate Control is set to User Yes or No Descramble Mode This parameter selects whether the receiver should scramble the output even if it is authorized to receive the channel The default mode is Descrambled Scrambled Scrambles the output channel even if the PE is authorized and can descramble the channel Descrambled Descrambles the output channel and passes in the clear channel...

Страница 119: ...eams Menu Item Description Parameters User Rate Mbps This parameter controls the output rate when Rate Control is set to User Note Output data will be partially or completely lost if the payload bit rate of the transport to be encapsulated is lower than the user defined output bit rate 0 to 206 Mbps Intf Mode This selects the MPEG over IP output mode None Disables the MPEG over IP interface Data P...

Страница 120: ...n port number 1 to 65534 Note If you selected RTP for MOIP you must select an even destination port number Note We recommend that you do not use destination UDP ports reserved by the IANA SrcPort This selects the source UDP port number 0 to 65535 Note Set the SrcPort to 0 to use the default source UDP port 49162 Send SAP This selects whether to send Session Announcement Protocol messages None or R...

Страница 121: ...a program basis where individual service PID modifications are provided on a limited scale Use the digital program mapping features to configure the transport output bit rate configure the output mode for a program entry configure the service and PID output settings in a program entry Note Any changes made to the ASI MOIP DPM values will automatically change the Config Type to Edited by User The D...

Страница 122: ...te the tables if the content has changed Copy This copies all DPM data from either the ASI output to the MOIP output MPEG over IP or from the MOIP output to the ASI output depending on your selection ASI MOIP or MOIP ASI ASI MOIP Menu Item Description Parameters PE Select the Program Entry to configure 1 or 2 main program 1A or 2A auxiliary program InCh Displays the channel number to which the PE ...

Страница 123: ... configuration The output map for example output channel PMT does not change automatically if the input or channel number is changed Drop The current channel is not sent to the output and its PMT is removed from the output The OutCh PMT and PID map entries are ignored XCode Provides the flexibility to define all the outgoing PID numbers for a PE including those not currently on transmission as in ...

Страница 124: ...ed if the Map Mode menu is set to Svc ID PID PSI Remap Every input PID can be mapped to only one output PID If PID mapping conflicts exist DPM will use the Precedence Rule to decide which output PID to use All PMTs using the input PID will be updated to reference the output PID specified by the winner Pkt Copy An input PID can be mapped to multiple output PIDs The PID will be duplicated as many ti...

Страница 125: ...s the generated PSI tables on the longest intervals that are allowed by MPEG standard SA Std Transmits the generated PSI tables based on PowerVu standard intervals Service ID Select whether the receiver should always generate PSI tables for the Mapped PE even if the selected input channel is not available or for only valid service channels IDs Valid Ch Only transmits the PSI tables for the mapped ...

Страница 126: ...e PID Map to be configured The PID map is used to map input services to output PIDs If the PE action is Pass or PE action is Map and Map Mode is Svc ID only entries which drop a service are applied and all other services are passed through If the PE action is Map and Map Mode is Svc ID PID all entries are applied Any services not mapped by an entry will be dropped Press up and down to scroll throu...

Страница 127: ... applied UNKN ETV CDT LSDT DATA TTX MPE DPI VBI SUBT AUD VID PCR or INVL In Select the instance of the service specified by OutType to configure If an input service matches this type and instance then the Action will be applied 1 to 64 PID If mapping this PID Act is set to Map select the output PID number 1 to 8190 PSI Table Settings Note The table settings are only available if you selected Ctl b...

Страница 128: ...ted because the CDT is referred to within the PMT rather than outside the PMT Select Pass to permit the output of CDTs following the configured DPM PID map configuration and all other DPM constraints If a DPM PID map has not been configured for the CDT PID and the PE Act is set to Map the CDT will still not output Select Drop to override the DPM PID map configuration for CDT PIDs and to always dro...

Страница 129: ...ad configuration data will be displayed and you will need to change the parameters to obtain the correct output 7 Go to Setup Outputs TS Out ASI and set the Output Mode to Full DPM Control Also if necessary set the Descramble Mode according to whether the program is to be Scrambled or Descrambled for downstream viewing monitoring 8 On the same menu set the following parameters Parameter Descriptio...

Страница 130: ...ervices are mapped correctly 1 On the DPM menu map the output services as desired 2 Select PE Resync Svcs The receiver will synchronize the PE output according to the available input services only and ignore the input to output service PID mapping To synchronize the output to the input PIDs only This operation synchronizes the inputs to the outputs according to the PID assignments only This is use...

Страница 131: ...ccording to the preset template This is helpful in pre configuring any number of PEs for future use TS Out Transcode To view the Transcode menu from the TS Out menu press the RIGHT arrow key three times The Transcode menu allows you to convert MPEG 4 HD services to MPEG 2 for use in CATV headends Video and two audio monitoring outputs are available for confidence monitoring of the decrypted incomi...

Страница 132: ...menu HD Output Up converts from SD to HD1080i when receiving an SD input signal HD horizontal resolution will follow the HD Res parameter on this menu HD720p Sets the output vertical resolution to HD720p regardless of the input resolution HD1080i Sets the output vertical resolution to HD1080i regardless of the input resolution HD HRes This selects the transcode channel HD horizontal output video r...

Страница 133: ...he encoded bit stream to improve the video quality of the transcoded stream Amongst others if the incoming GOP structure is similar to that of an MPEG 2 it will reuse the frame allocations from the incoming stream as long as GOP Control is set to I Frame Sync If the downstream transcoder does not support altering GOP structures set the GOP Control setting to User GOP MN This will also require the ...

Страница 134: ... the order to output the closed caption packets on the transcoded SD output None SCTE 20 or CEA 708 The default is CEA 708 Op Mode Sets the subtitle mode for inserting subtitles in the transcoded video Off No subtitles are displayed On Displays DVB or Imitext subtitles if available DVB Displays only DVB titles if available Otherwise no subtitles are displayed Imitext Displays only Imitext subtitle...

Страница 135: ...rder If PMT Order was selected in the Select Language By menu select the subtitle transcoded video entry to display This information is available from your uplink service provider First to Eighth Entry If Language Entry was selected in the Select Language By menu select the subtitle PID entry to display The information is available from your uplink service provider Enter the three character code p...

Страница 136: ...hannel 1 Verify that you are receiving a valid signal and that you have set up the channels that you want to transcode 2 Go to Setup Outputs TS Out DPM ASI and set the Output Mode to Transcoding You will be prompted to Resync All for the selected output This resynchronizes the inputs to outputs for the current PMT according to the service assignments and the PIDs for the PE 3 Press MENU to exit th...

Страница 137: ...oding such as bitrate GOP and resolution to the local transcoder settings for the selected program entry This is only supported with an uplink that uses uplink transcoding controls for the user address of the selected program entry Yes or No TS Out Options To view the Options menu from the TS Out menu press the RIGHT arrow key four times The Options menu allows you to configure auto synchronizatio...

Страница 138: ...M assigns new values for all the output channels and PIDs according to the options below when you Resynchronize All Yes or No Use Inp Chan PMT PIDs Set to Yes to use the input channel numbers PMT PID numbers and or ES PID numbers Otherwise set to No to use the Start channel and channel Step assigned below Yes or No Start First PE channel to use if the Use Inp Chan PMT PIDs is set to No 1 to 65535 ...

Страница 139: ...el numbers 1 to 65535 for Use Inp Chan 1 to 8192 for Use Inp PMT PIDs Use Inp Ord Set to Yes to assign the ES PID according to the incoming PMT order Otherwise set to No to use reserved PIDs defined below Yes or No PCR VID AUD SUBT VBI DPI MPE TTX Data LSD CDT ETV Set the number of PIDs for the specified streams in one channel 1 to 64 ...

Страница 140: ...your service provider The CA menu has the following structure Menu Item Description Parameters Id Select the ISE to configure 1 or 2 User Address Indicates the ISE User Address 11 digit address in the following format ISE Version Indicates the ISE version number 7 characters ADP Enc Pass Indicates the number of encrypted Addressable Data Packets successfully processed Ideally the ADP Enc Pass and ...

Страница 141: ...ower cycled BISS Mode Sets the Basic Interoperable Scrambling System BISS mode for the receiver All channels assigned to a PE identified as BISS CA controlled in the PMT will be decrypted Mode 1 or Mode E BISS 1 SW If BISS Mode is Mode 1 enter the session word 12 character password Once entered it cannot be viewed and it is only displayed as asterisks Contact your program provider for the session ...

Страница 142: ...rp PMT Timeout Yes Yes Yes i s Menu Item Description Parameters FP Alarm Reminder Select whether to display alarms and warnings on the front panel The alarm indicator will intermittently flash in the lower line if enabled Enable or Disable Alarm Vid Cutoff Select whether the video output is cut off if any enabled alarm is active on the receiver When video is cut off there will be no horizontal or ...

Страница 143: ...cates the setting is Yes but is currently being suppressed because the alarm or warning is disabled Enb is set to No Setup Menu NoiseCutoffs To view the Noise Cutoffs menu from the Main menu press the RIGHT Arrow key once and then the SELECT key to reach the Setup menu Then press the RIGHT arrow key eight times and the SELECT key to view the Noise Cutoffs menu The Noise Cutoffs menu allows you to ...

Страница 144: ...gins in dB above the transport outputs that will be muted The receiver uses these thresholds to determine when to restore the transport after it has been muted 30 0 to 30 0 This setting must be above the respective Cutoff value The default is 0 1 Note Muting Control must be set to Enable for these settings to be active The following displays the Transport Default C N Margin Relationship Audio DVBS...

Страница 145: ...udio Default C N Margin Relationship Restore Defaults Select to restore the default muting thresholds Muting Control Select whether to enable or disable muting cutoffs If disabled all the other settings are ignored Enable or Disable The default is Enable Setup Menu DR To view the DR Disaster Recovery menu from the Main menu press the RIGHT arrow key once and then the SELECT key to reach the Setup ...

Страница 146: ...Yes after five minutes This prevents the user from accidentally disabling disaster recovery permanently To disable disaster recovery remove all the disaster recovery configurations Backup Channel and Backup Transport settings The maintenance mode allows you to perform any maintenance operations such as IP setup without the unit declaring disaster and initiating a disaster recovery search path Note...

Страница 147: ...must wait after detecting a signal loss before declaring a disaster The default is 120 seconds 5 to 2160000 seconds Signal Lock Timer Select the time in seconds the unit must wait for a signal lock before declaring that the signal is not usable and move on to the next search location in the search path The default is 30 seconds 5 to 255 seconds Verify Timer Select the time in seconds the unit must...

Страница 148: ... backup is enabled To activate a backup press the ADV key and press SELECT to insert The Active menu for the selected backup number changes from No to Yes Press APPLY to save the changes To disable a backup press the ADV key and press the RIGHT arrow once and press SELECT to select Delete Press the RIGHT arrow once and press SELECT to select Continue The Active menu for the selected backup number ...

Страница 149: ...ucture General Menu Item Description Host Name Sets the host name of the current unit It is a user configurable name that appears on the Web Interface title to identify the transcoder Tracking ID Displays the unique Tracking ID number that identifies the product version This is read only Model Indicates the model number and name of the transcoder This is read only Master UA Indicates the Master Us...

Страница 150: ...number of transcoding paths 1 or 2 Licenses Menu Item Description Parameters Feature Displays a list of software licenses for the D9858 Advanced Receiver Transcoder Press up and down to scroll through the list of features Digital Fingerprint Trigger Statmux 2nd Transcoder Channel HD Transcode Enb Indicates whether the selected software feature is licensed and enabled Note All software licenses are...

Страница 151: ...T key The Versions menu provides basic software information that is useful when requesting customer support from Cisco The menu has the following structure MainVersions The following are the version numbers applicable to the Main printed circuit board Menu Item Description App Current Indicates the version of the current application ...

Страница 152: ...egister Indicates the version of FPGA code read from the FPGA CPLD Primary CPLD Secondary Indicates the versions of the current primary and secondary Complex Programmable Logic Device CPLD Application Select Erase Application Select between all versions of the application loaded on the current unit Select Select and then scroll to Yes to reboot the unit and load the selected application You will b...

Страница 153: ...ownload first For more information on aborting the download see Setup Menu Admin on page 58 Transcoder Versions The following are the version numbers applicable to the Transcoder printed circuit board Menu Item Description Host Root FS Host Kernel Indicates the Host Root FS and Kernel version numbers Host Boot Indicates the Host Boot version number Interface Indicates the Interface version number ...

Страница 154: ...m event messages Press the UP and DOWN arrow keys to scroll through the list of alarms and warnings Press the LEFT and RIGHT arrow keys to view the set and reset times Press the INFO key to view the detailed message Clear History Select to clear any existing history information Logs Menu Item Description View Logs Select to view the system log messages Press the UP and DOWN arrow keys to scroll th...

Страница 155: ...3 5 2 3 3 4 4 5 5 6 7 8 8 9 or 9 10 Pol Polarity of the received signal H V or Off Horiz Horizontal Vert Vertical Circ_l Left Circular or Circ_r Right Circular ONID Original Network ID SymRate Symbol Rate in Mbps Modulation Modulation of the signal QPSK DVB S QPSK DVB S2 8PSK DVB S2 or 16QAM DVB S2 OrbPos Orbital Position of the satellite in degrees East or West PSI Channels This is the Virtual Ch...

Страница 156: ...M Even EMM MPE DPI DRT CDT MCT MIT MAT ECT or Invalid Table ID Tbl ID Unique Table ID ID MPEG DVB Table ID Ver Table Version number PID Value of the PID on which the table is present Status Reception status of the table None Partial Full Update Timeout or Lost Sections Number of sections in the table Power On Menu Item Description Creation Date and Time Displays the date and time the current unit ...

Страница 157: ...learable reset counter was last cleared Clr Rst Select this option to clear reset the Clrbl Rst counter to 0 Reason For Last Reset Displays the reason for the last reset Health Monitor Menu Item Description Parameters Cur Temp Max Temp Avg Temp Displays the current Cur Temp maximum Max Temp and the average Avg Temp operating temperature Degrees Celsius Fan1 to Fan7 RPM Displays the fan speed for t...

Страница 158: ......

Страница 159: ...eb GUI Setup and Monitoring In This Chapter Logging On to the Web GUI 138 D9858 Summary Overview 139 D9858 Menus 142 D9858 Web GUI Environment 144 Setting up Input Information 145 Setting up Audio and Video Information 175 Configuring Transport Stream Information 189 Configuring System Settings 228 Viewing Support Information 263 ...

Страница 160: ... your username and password you can reset them from the front panel menu of the D9858 Advanced Receiver Transcoder For more information see Resetting the Login Credentials on page 32 Important The password and user name will be remembered for the whole of the web session Close the web browser if you want to prevent others from accessing the settings of the D9858 Advanced Receiver Transcoder If you...

Страница 161: ...gs of the D9858 Advanced Receiver Transcoder Shortcuts The shortcuts above the modules in the Summary Dashboard page are shortcuts to the various setup pages For example click Video Setup to open the Video Setup page Modules You can customize the Summary Dashboard by temporarily minimizing or removing the modules displayed Each module has a maximize and minimize button allowing you to view or hide...

Страница 162: ...us Tuner Performance Displays the satellite dish status such as the C N Margin and Signal Level Video Status Displays the current video information Channel Status Displays the channel status information such as the type of CA used and whether the receiver is authorized to receive the signal PID Information Displays the PIDs associated with the channels Fault Active List Displays the currently acti...

Страница 163: ...or Warnings link and a pop up window is displayed with a list of all the active alarms or active warnings The following is an example Click an alarm or warning to open the Status page for more information For more information on the Status page see Viewing the Alarm Warning Status on page 241 ...

Страница 164: ...esholds View input status Configure channels Configure CI Common Interface settings View PSI Frequency and Channel tables Audio Video From this menu you can Configure video settings Set up closed caption and subtitles Configure audio settings View current audio status Set the cueing parameters Transport Stream From this menu you can Configure ASI and MPEGoIP outputs Configure transcoder settings S...

Страница 165: ...8 Menus 143 Set date and time formats Configure lock levels Import or export settings file Manage accounts Support From this menu you can View logs View contact information View and upgrade software version ...

Страница 166: ...D9858 has the following general buttons Button Description Apply Saves and applies the settings to the transcoder Refresh Reads existing data from the D9858 If edits were made in a setup page then unsaved changes are discarded Reset Defaults Discards any changes made and sets data to default values Clear Counters Resets counters on the displayed page ...

Страница 167: ...ion on NIT retune see NIT Retune Recovery on page 10 For more information on disaster recovery see Disaster Recovery on page 7 1 From the user interface of the D9858 choose Input Input Setup The Input Setup page is displayed 2 In the RF Input Selection area check the Use RF Input check box to activate an RF input You can select RF 1 to RF 4 3 Choose UserCfg from the Input Selection drop down list ...

Страница 168: ...rs close to the same frequency 10 From the IQ drop down list choose the input signal spectrum inversion setting which allows the operator to track and select inverted and non inverted digital signals This is normally used to automatically reject or filter out unwanted signals When set to Auto signal is tracked and inverted for correct selection as required When set to Opposite the signal is always...

Страница 169: ...larity of the signal connected to the current RF input 17 In the Orbital Posn field enter the Orbital Position for RF1 RF2 RF3 and or RF4 in degrees This is the location in orbit of the satellite currently being used The satellite position in degrees in combination with the direction either E East or W West denotes the satellite position the dish connected to the current RF Input should point This...

Страница 170: ...ion displays the current RF status The following table describes the Current Input Status information displayed Parameter Description Frequency GHz The current downlink frequency in GHz L band Frequency MHz The current L Band frequency in MHz Symbol Rate Msym Symbol rate of the received signal in Msymbols second FEC Rate The FEC Forward Error Correction rate of the received signal N A 1 2 3 5 2 3 ...

Страница 171: ...SI tables have been found Orbital Validation Status Displays the status of the last user orbital validation performed It displays Passed if the last orbital validation was successful or None if a orbital validation was never performed Otherwise it will display a reason for the failed validation Orbital Validation Status Date Displays the last date and time that the user orbital validation was perf...

Страница 172: ...SI Input Status area displays the current RF status The following table describes the ASI Input Status information displayed Parameter Description Active Input Indicates the currently selected input source RF1 RF2 RF3 RF4 or ASI Signal Status Indicates whether the input signal is locked Locked Indicates the transcoder is locked to a carrier with no valid content Lock Sig Indicates the transcoder i...

Страница 173: ...ansport synchronization status Error Ok or N A ASI Packet Size bytes Indicates the packet size in bytes for the ASI input 188 204 or N A Acquisition State Displays Full if the ASI and PSI tables have all been found Otherwise it will display Degraded if there are missing tables or None if no ASI or PSI tables have been found TS ID The Transport ID in the range from 1 to 65535 ...

Страница 174: ...ne see NIT Retune Recovery on page 10 For more information on disaster recovery see Disaster Recovery on page 7 1 From the user interface of the D9858 choose Input SI Receive Setup The SI Receive Setup page is displayed 2 In the Custom Tuning Mode area from the Acquisition Mode drop down list choose the tables required for the service list creation and signal acquisition The selections are Auto Ba...

Страница 175: ...Information Table NIT drop down list choose Yes to use the NIT when creating the service list 6 From the Service Description Table SDT drop down list choose Yes to use the SDT when creating the service list 7 From the Program Association Table PAT drop down list choose Yes to use the PAT when creating the service list Note You cannot change the Bouquet Association Table value It is not supported i...

Страница 176: ...he SI Receive Status The SI Receive Status area displays all the current SI Receive settings It also displays the source of last tuning and the last Preset Number activated The Service List From area displays the current settings of the allowed services BAT NIT SDT PAT ...

Страница 177: ...ort in the event of a noisy poor or loss of signal condition The adjustable operating range is from 30 0 to 30 0 dB This setting must be below the respective Restore value The default setting is 0 0 Note The Enable Threshold Muting check box must be checked for these settings to be active 4 The Transport Restore field for both DVB S C N Margin dB and DVB S2 C N Margin dB sets the DVB S and DVB S2 ...

Страница 178: ...ective Restore value The default setting is 0 0 Note The Enable Threshold Muting check box must be checked for these settings to be active 6 The Audio Restore for both DVB S C N Margin dB and DVB S2 C N Margin dB sets the DVB S and DVB S2 Carrier to Noise margins in dB above the audio outputs that will be restored The unit uses these thresholds to determine when to restore the audio after it has b...

Страница 179: ... Recovery Settings The disaster recovery settings allow you to configure the search path when a disaster occurs By default the disaster recovery feature is enabled For more information on disaster recovery see Disaster Recovery on page 7 Note If the unit is in a disaster recovery or NIT retune recovery mode an error message is displayed informing you that any changes made to the page will interrup...

Страница 180: ... all the disaster recovery configurations Search Pathsettings below The maintenance mode allows you to perform any maintenance operations such as IP setup without the unit declaring disaster and initiate a disaster recovery search path Note Although the default is set to Yes the disaster recovery is not operational until the Search Path is configured 3 From the Disaster Recovery Profile drop down ...

Страница 181: ... Local in the Signal Verify Period field enter the time in seconds the unit must wait for the PAT table to verify the signal has a valid transport You can enter a value in the range from 10 to 255 seconds The default is 60 seconds 7 The Search Path area determines the search order of backup transports when a disaster occurs For a list of triggers see Disaster Recovery on page 7 During a disaster t...

Страница 182: ...te We recommend that you configure a minimum of one backup transport If no backup transports are configured the origin channel is used The configured backup is enabled To disable a backup click the Backup 1 Backup 2 or Backup 3 radio button and click Disable 8 Click Apply If a disaster recovery is in progress a message is displayed recommending that you do not apply the setup changes during a disa...

Страница 183: ...Disaster Recovery Status page is displayed The State field displays the current disaster recovery status The table below lists the statuses State Description No Disaster D R Ready The unit is in a normal state and no disaster recovery is in progress It is set to use the local or uplink disaster recovery settings depending on the Configured By field ...

Страница 184: ...t of data for the backup plan service in the Disaster Recovery Table DRT exceeds the allowable limit from the current unit Contact your PNC uplink administrator to reduce the amount of backup plan IDs in the Uplink Configuration No Disaster D R Not Ready No Search Path The unit is in a normal state but the unit is not ready for disaster recovery due to a missing search path from the PNC uplink The...

Страница 185: ... reasons Tuning descriptors in the DRT is empty As a result there is no match for the origin The tuning descriptors in the DRT consist of only one tuning parameter which matches with the origin Since other tuning descriptors are empty there are no transports for the search path Contact your PNC uplink administrator D R in progress D R Not Ready Malformed DRT The disaster recovery is in progress bu...

Страница 186: ...tune to the specified backup signal on the search path Contact your PNC uplink administrator Goto Origin OK FAIL No Action The GOTO Origin command from the uplink executed successfully failed to execute or did not execute due to the following Backup with assigned origin transport is not in the search path Already tuned to origin transport The GOTO Origin command instructs the unit to tune back to ...

Страница 187: ...it is not connected to the uplink the default values of the unit are displayed For more information contact your PNC uplink administrator The Backup Transport area displays the tuning parameters of the current origin and backup transports configured For example if only Backup 1 and Backup 3 are configured the table will display the tuning parameters for Origin Backup 1 and Backup 3 The Configured ...

Страница 188: ...to the page For more information on NIT retune see NIT Retune Recovery on page 10 For more information on disaster recovery see Disaster Recovery on page 7 1 From the user interface of the D9858 choose Input Channel Selection The Channel Selection page is displayed 2 The D9858 is available in a single channel Cisco D9858 1 or a dual channel configuration For a dual channel transcoder you can enter...

Страница 189: ...e Program Entry PE1 only Channel Displays the input channel of the current PE The channel is displayed in a range from 1 to 65535 Channel Name Displays the channel name of the current PE Conditional Access System ID Indicates the type of Conditional Access CA system used by the program SA BISS or FTA Channel Authorised Indicates whether the receiver is authorized to receive the program Yes or No C...

Страница 190: ...playing the alternate program event as it is not authorized to view the scheduled event SR Type Indicates the type of service replacement event The types are None Scheduled CA Cue Trigger None Indicates that no service replacement event is scheduled Scheduled Indicates that all transcoders will tune to the alternate program at the scheduled time This status applies to PE1 and PE2 for D9858 or PE1 ...

Страница 191: ...encrypted Addressable Data Packets successfully processed Ideally the ADP Enc Pass and ADP Enc Total numbers should be identical Enc Data pkts recvd Indicates the number of encrypted Addressable Data Packets received Ideally the ADP Enc Pass and ADP Enc Total numbers should be identical Non Enc Data pkts passed Indicates the number of non encrypted Addressed Data Packets successfully processed Ide...

Страница 192: ...ed 12 character BISS Mode 1 session word in the BISS Mode 1 Session Word field Once entered it cannot be viewed and it is only displayed as asterisks Contact your program provider for the session word 4 If you selected BISS Mode E enter the 16 character BISS Mode E encrypted session word in the BISS Mode E Encrypted Session Word field and the 14 character BISS Mode E injected ID in the BISS Mode E...

Страница 193: ...ion Table Type Indicates the MPEG table acronym PAT CAT PMT TSDT NIT NIT Other SDT SDT Other BAT AEIT P F OEIT P F TDT RST ST TOT DIT SIT ECM Odd ECM Even EMM MPE DPI DRT CDT MCT MIT MAT ECT or Invalid Table ID Table ID Extension Displays the MPEG DVB Table ID Status Indicates the reception status of the table None Partial Full Update Timeout or Lost Version Indicates the table version number PID ...

Страница 194: ...D Frequency GHz Displays the downlink frequency in GHz 0 0 to 15 0 GHz Symbol Rate MSym Displays the symbol rate in Mbps Orbital Position Displays the orbital position of the satellite in degrees East or West Polarization Displays the polarity of the received signal H V or Off Flag Displays the satellite position in degrees in combination with the direction East or West FEC Indicates the Forward E...

Страница 195: ... is a list of the various columns Abbreviation Description Service ID Indicates the virtual channel number TS ID Displays the identification number of the transport on which the channel is available For more information on the transport streams see Viewing PSI Frequency Information on page 172 Program Name Indicates the name of the channel PMT PID Indicates the PID of the channel s Program Map Tab...

Страница 196: ...only Type Name assigned to the Program Entry up to 4 alphanumeric characters Detail Displays any detail associated with the program PID for example MPG2 PID The parameters are MPG1 VID MPG2 VID 422 VID H264 VID HD VID MPG4 VID MPG AUD MPG2 AUD DVB AC3 DVB DDP AAC AUD HEAAC AUD MPG4 AUD DBE AUD DTS AUD DVB TXT DVB VBI DVB SUBT DVB ASYN DVB SYNS DVB SYND DVB MPE DVB DCAR DVB OCAR SA VBI ATSC AC3 ATS...

Страница 197: ...D for 625 line systems 4 From the Standard Definition Aspect Ratio drop down list choose the Standard Definition aspect ratio of your TV monitor 4 3 or 16 9 The default is 4 3 Set it to the corresponding value 5 From the Selected Aspect Ratio Conversion drop down list choose the aspect ratio conversion that the unit will perform on the incoming signal for the picture to be displayed correctly on y...

Страница 198: ... encoding bit rate FPS and aspect ratio of the incoming signal The fields are read only The following table describes the video status information displayed Video Status Description Primary Video Output Indicates the actual output video format Auto HD 720p HD 1080i or SD Standard Definition Output Displays the actual standard definition format of the primary video output if the PV Output is set to...

Страница 199: ...yed 2 From the Preferred Closed Caption Mode drop down list choose the type of closed captioning to use if there are multiple available in the stream The default is Auto Note SA Custom is not supported when telecine video coding is enabled 3 The Closed Caption Mode field displays the actual closed caption mode in the output This is read only 4 Click Apply ...

Страница 200: ...Imitext Displays only Imitext subtitles if available Otherwise no subtitles are displayed 3 From the Imitext Position drop down list choose the position of the on screen subtitle text Standard or Extended 4 From the Imitext Foreground Color drop down list choose the color for Imitext subtitles Auto displays text in the color transmitted by the subtitling equipment Yellow and White overrides the co...

Страница 201: ... the MPEG language to display from the available list The following are the available options ara Arabic btk Batak Indonesia ben Bengali bul Bulgarian chi Chinese cze Czech dan Danish dut Dutch eng English fin Finnish fre French ger German gre Greek heb Hebrew hin Hindi hun Hungarian ice Icelandic ind Indonesian ita Italian jpn Japanese kor Korean may Malay mul Multiple Languages nor Norwegian per...

Страница 202: ...pVBI 1 From the user interface of the D9858 choose Audio Video VBI The VBI page is displayed 2 Check the Enable VITS on PAL Lines 17 18 330 and or 331 check boxes to enable the Vertical Interval Test Signal on PAL Lines 17 18 330 and or 331 3 Click Apply ...

Страница 203: ...t If Language Entry is selected you must a language code in the Manual Entry field If the languages selected are different the first PID with the matching language will play on the appropriate audio device Audio 1 or Audio 2 If you select the same language for both Audio 1 and Audio 2 the PIDs are mapped as follows the first matching language PID to Audio 1 and the second matching PID to Audio 2 c...

Страница 204: ...dio channel You can select a value in the range from 6 0 dB to 6 0 dB in increments of 0 5 dB d From the Right Attenuation drop down list choose the volume adjustment for the Right audio channel You can select a value in the range from 6 0 dB to 6 0 dB in increments of 0 5 dB 4 Click Apply Viewing the Audio Status and Audio PIDs The Audio Status area displays the current audio settings The followi...

Страница 205: ...are MPG1 VID MPG2 VID 422 VID H264 VID HD VID MPG4 VID MPG AUD MPG2 AUD DVB AC3 DVB DDP AAC AUD HEAAC AUD MPG4 AUD DBE AUD DTS AUD DVB TXT DVB VBI DVB SUBT DVB ASYN DVB SYNS DVB SYND DVB MPE DVB DCAR DVB OCAR SA VBI ATSC AC3 ATSC DDP SA UTLD SCTE DPI SA HSD SA CDDL SA WBD SA SUBT ECM EMM PCR or UNKNOWN Language Displays the language code of the audio PID if applicable PID Indicates the audio PID n...

Страница 206: ...High for the pins to act as open or floating collectors on an active cueing signal and as ground on an inactive signal Select Low for the pins to act as ground on an active cueing signal and as open or floating collectors on an inactive signal 4 If the Cueing Mode is set to Tone set the number of consecutive tone sequences to be generated in the Cueing Tone Repeat Count field Values greater than 1...

Страница 207: ...e rear panel of the receiver The following table shows what the possible field settings are and their relationship to the receiver output Relay Mode Condition Relay Contact NC C C NO Alarm Unit Power Off Open Close Alarm State Open Close No Alarm Close Open Trigger Active selected in PNC Close Open Inactive Open Close 8 If the Relay Mode is set to Trigger choose the cue trigger bit pin that will a...

Страница 208: ... is displayed 2 In the Test Tones field enter the three digit tone sequence You can enter a value between 000 and 999 3 From the Sequence Mode drop down list choose the tone sequence mode The following describes the available options Start tone only End tone only Start and end tones The end tone is signaled after waiting the time specified in Delay sec 4 Click Apply ...

Страница 209: ...hoose to enable or disable the current tone sequence When disabled no cue tone is output 4 In the Sequence Tones field set the three digit tone sequence 1 to 999 5 Choose the tone sequence mode from the Sequence Mode drop down list Choose for start tone for the end tone and for the start and end tones The end tone is signaled after waiting the time specified in Sequence Delay 6 If the Sequence Mod...

Страница 210: ...om the user interface of the D9858 choose Audio Video Decode Enables The Decode Enables page is displayed 2 Check the services to be decoded by the unit Check or uncheck the Enable Decode Engine check box to check or uncheck all the services in the list 3 Click Apply ...

Страница 211: ...r you make any changes a successfully updated session open message appears The changes are displayed but not saved You must click Apply to save and apply the changes Note Any changes made to the ASI DPM values will automatically change the Mode Status to Edited by User 2 Choose the output rate control from the Rate Control drop down list The following table describes the affect each of the setting...

Страница 212: ...hat you use either one of these basic modes or for advanced setup enter the DPM mapping before setting the Output Mode The following table describes each mode Output Mode Description No Output No ASI output will be generated and the ASI port will be disabled Passthrough All PEs will be set to Pass and other DPM settings will also be set Service Channels Only This is similar to Passthrough except t...

Страница 213: ...d PID Conflicts table when you click View Conflicts You can then resolve the conflicts manually If a conflict occurs and Enable Auto Map for Collision is set to Yes a message that the conflicts will be fixed automatically and the Output Channel and PID Conflicts table is empty For channel conflicts the system will only automatically change the duplicated output channel numbers If both PE actions a...

Страница 214: ...rom the Null Packet Insertion drop down list choose Yes to insert null packets into the output to maintain output at a constant bit rate Otherwise choose No Note We recommend that you set the Null Packet Insertion to Yes especially if the Output Mode is set to Transcoding 8 Click Apply Setting Up the ASI Auto Synchronization Options The ASI Auto Sync area allows you to configure the DPM without ed...

Страница 215: ...l Number is set to 100 and the Channel Numbers Offset is set to 10 then the first channel number is 100 and the second channel number is 110 b From the Use Input PMT PID Numbers drop down list choose Yes to use the input PMT PID number Otherwise choose No default to use the first PE PID number and PID offset number assigned below i In the First Channel First ES PID Number field set the first PE PM...

Страница 216: ...X DATA LSD CDT ETV fields enter the number of PIDs for the specified streams PCR VID AUD SUBT VBI DPI MPE TTX DATA LSD CDT ETV in one channel e Click OK 4 From the Enable Auto Map For Auxiliary PEs drop down list choose Yes for the DPM to set the output actions for all the Auxiliary PEs to MAP when the Output Mode is set to Transcode If the Enable Fixed Table Output is set to Yes the output config...

Страница 217: ...ital Program Mapping under ASI Output The ASI Digital Program Mapping page is displayed 2 For each DPM Program Entry it displays the input channel number Chl and channel Name There are two channels PE1 and PE2 with two auxiliary channels P1A and P2A The auxiliary channels automatically tune to the corresponding PE channels If the PE is not transcoded the auxiliary PE is dropped Note The D9858 is a...

Страница 218: ...d outputs are the same 4 Select the program entry you want to edit 5 Click Edit The DPM PE PID MAP dialog box opens 6 In the Output Channel field enter the output channel number you want to map to the input channel Input Channel This value is only used if the PE Action was set to Map You can enter a range from 1 to 65535 7 Enter the Output PMT PID you want to map to the Input PMT PID 8 In the PE P...

Страница 219: ...y used if the Action is set to Map The categories are UNKN CDT LSDT DATA TTX MPE DPI VBI SUBT AUD VID PCR or INVL 13 Enter the Instance 1 to 64 of the service specified by Category to configure If an input service matches this type and instance then the Action will be applied 14 If Action is set to Map enter the Output PID number 0 to 8192 15 Click Save 16 Click OK To remove a PID mapping click th...

Страница 220: ...g is displayed Click View Conflicts to view a detailed list of all the conflicts in the Output Channel and PID Conflicts window For channel conflicts the system will only automatically change the duplicated output channel numbers If both PE actions are set to Map or XCode the output channel number of the higher PE is changed Otherwise the output channel number of the mapped and transcoded PE is ch...

Страница 221: ...e Precedence Rule to decide which output PID to use All PMTs using the input PID will be updated to reference the output PID specified by the winner Pkt Copy An input PID can be mapped to multiple output PIDs The PID will be duplicated as many times as needed up to a certain hardware limitation Note This may increase the output bandwidth of the stream Pkt Copy is recommended for most applications ...

Страница 222: ...rated PSI tables output rate to the incoming rate MPEG Min Transmits the generated PSI tables on the longest intervals that are allowed by MPEG standard SA Std Transmits the generated PSI tables based on PowerVu standard intervals 7 From the PSI Table Output Option drop down list choose the action to perform on the PSI tables for the output stream The following table describes each option PSI Opti...

Страница 223: ...thin the PMT rather than outside the PMT Check the Block CDT Output check box to override the DPM PID map configuration for CDT PIDs and to always drop all CDTs Otherwise uncheck the Block CDT Output check box to permit the output of CDTs following the configured DPM PID map configuration and all other DPM constraints 9 From the PSI Regeneration Option drop down list choose whether to regenerate t...

Страница 224: ... D9858 choose Transport Stream Output Transport Status under ASI Output The PID Output Status page is displayed The Program Entry Referenced PIDs table displays the specified PE ES PIDs information on the output The Output Channel and PID Conflicts table displays a list of conflicts when the DPM alarm is active ...

Страница 225: ... choose the DPM output rate control The following table describes the affect each of the settings has on the output bit rate Rate Control Description Auto The output rate follows that set by the uplink This setting can be used if the signal source is ASI If Null Packet Insertion is set to Yes the output bit rate is the same as the input rate including all the null packets If Null Packet Insertion ...

Страница 226: ...owing table describes each mode Output Mode Description No Output No MPEGoIP output will be generated Passthrough All PEs will be set to Pass and other DPM settings will also be set Service Channels Only Only service channels will be output MAP Passthrough The output will be identical to the input except that channels assigned to PEs and PIDs will be mapped using the DPM settings If the input is t...

Страница 227: ...f a conflict occurs and Enable Auto Map for Collision is set to Yes a message that the conflicts will be fixed automatically and the Output Channel and PID Conflicts table is empty For channel conflicts the system will only automatically change the duplicated output channel numbers If both PE actions are set to Map or XCode the output channel number of the higher PE is changed Otherwise the output...

Страница 228: ...rol is set to User and the configured output bit rate is higher than the payload rate of the transport stream to be encapsulated Note We recommend that you set the Null Packet Insertion to Yes especially if the Output Mode is set to Transcoding 8 In the SAP Multicast IP Address field set the Session Announcement Protocol destination IP address This is the IP address where the SAP announcements are...

Страница 229: ... detected you can review the new changes and click Apply to accept the new changes Choose No and a detailed list of all the conflicts is displayed in the Output Channel and PID Conflicts table click View Conflicts when a conflict occurs You can then resolve the conflicts manually 3 From the Enable Fixed Output drop down list choose Yes for the DPM to assign new values for all the output channels a...

Страница 230: ... In the First Channel First ES PID Number field set the first ES PID number The default is 101 ii In the First ES PID Numbers Offset field set the offset of the subsequent ES PID numbers For example if the First ES PID Number is set to 101 and the ES PID Numbers Offset is set to 100 then the first ES PID number is 101 and the second ES PID number is 201 d From the Use Input PMT ES Stream Order dro...

Страница 231: ...cket 1 to 7 2 In the Minimum number Packets Second field enter the minimum number of transport packets per IP packet You can enter 0 or 2 to 1000 Configuring the MPEG over IP Stream 1 In the MPEG over IP Output page Transport Stream MPEG over IP Output click Stream The MPEG over IP Output Stream page is displayed The following table describes the stream information Stream Details Description Strea...

Страница 232: ...ngs click the radio button of the stream and click Advanced The following table describes the MPTS advanced settings Advanced Settings Description Traffic Class Sets the quality of service 0 to 255 Time to Live Max hops This sets the hop limit of the packet s lifespan 0 to 255 Source UDP Port This sets the source UDP port number 0 to 65535 Note Set the Source UDP Port to 0 to use the default UDP p...

Страница 233: ...n the MPEG over IP Output Main or Stream page The following Stream Status table is displayed The Stream Status table displays the status of the streams for the control and data ports Viewing the MPEG over IP Output Status The MOIP Output Status area MPEG over IP Output Main and Stream pages displays the current output bit rates for the control port and data port 0 to 206 Mbps the configured user r...

Страница 234: ...gital Program Mapping under MPEG over IP Output The Digital Program Mapping page is displayed 2 For each DPM Program Entry it displays the input channel number Chl and channel Name There are two channels PE1 and PE2 with two auxiliary channels P1A and P2A The auxiliary channels automatically tune to the corresponding PE channels If the PE is not transcoded the auxiliary PE is dropped Note The D985...

Страница 235: ...el field enter the output channel number you want to map to the input channel Input Channel This value is only used if the PE Action was set to Map You can enter a range from 1 to 65535 7 In the Output PMT PID field enter the output PMT PID you want to map to the Input PMT PID 8 In the PE PID MAP area you can select an existing PID mapping entry you want to modify or click Add Row to create a new ...

Страница 236: ... PID number 0 to 8192 in the Output PID field 15 Click Save 16 Click OK To remove a PID mapping click the radio button of the entry you want to remove and click Delete Synchronizing the Inputs 1 In the DPM Program Entry Setup table each PE output can be synchronized to its input according to one of the four output modes Click the radio button of the program entry you want to synchronize and then c...

Страница 237: ...s in the Output Channel and PID Conflicts window For channel conflicts the system will only automatically change the duplicated output channel numbers If both PE actions are set to Map or XCode the output channel number of the higher PE is changed Otherwise the output channel number of the mapped and transcoded PE is changed The new channel number selected is the next channel number that does not ...

Страница 238: ...ide which output PID to use All PMTs using the input PID will be updated to reference the output PID specified by the winner Pkt Copy An input PID can be mapped to multiple output PIDs The PID will be duplicated as many times as needed up to a certain hardware limitation Pkt Copy is recommended for most applications 4 Select the DPM action to use for Unreferenced Content Unreferenced content is th...

Страница 239: ...ansmits the generated PSI tables based on PowerVu standard intervals 7 From the PSI Table Output Option drop down list choose which PSI tables to include in the program output stream The following table describes each option PSI Options Description Pass All Transmits the incoming PSI Tables as is does not modify the content and rate Drop All Does not transmit any PSI Tables Ctl By Table The operat...

Страница 240: ...options see PSI Table Settings The CDT is different from the other tables listed because the CDT is referred to within the PMT rather than outside the PMT Check the Block CDT Output check box to override the DPM PID map configuration for CDT PIDs and to always drop all CDTs Otherwise uncheck the Block CDT Output check box to permit the output of CDTs following the configured DPM PID map configurat...

Страница 241: ...l and PID Conflicts table displays a list of conflicts when the DPM alarm is active Typical setupfor Digital Program Mapping DPM 1 Verify that you are receiving a valid signal and that you have set up the channels that you want to pass drop or map 2 From the user interface of the D9858 choose Transport Stream ASI Output or MPEG over IP Output 3 From the Output Mode drop down list choose Full DPM C...

Страница 242: ...Choose the input to output channel mapping from the Category drop down list Video and PCR can be output on the same PID or different PIDs If output on the same PID they will appear identical to the input 12 Click Save 13 Click OK 14 In the DPM General Setting area set the following parameters Parameter Description Remapping Mode Svc ID PID Duplication Method Pkt Copy Unreferenced Content Drop Serv...

Страница 243: ...nscoder 1 From the user interface of the D9858 choose Transport Stream Transcoding Transcoder Setup The Transcoder Setup page is displayed 2 From the Action on Loss of Input drop down list choose the action that the transcoder takes when there is a loss of input signal No Output or Black Output 3 From the Transcoder 1 Output and Transcoder 2 Output drop down lists choose the transcode channel vide...

Страница 244: ...l HD horizontal resolution will follow the HRes parameter set in the HD Settings area below 4 Click Apply Configuring Transcoder Settings Select the channel on which you want to configure settings and click Transcoder Config The Transcoder Settings dialog box is displayed If the selected channel is set to HD Output proceed as follows 1 In the HD Settings area select the transcode channel HD horizo...

Страница 245: ... from the incoming stream as long as GOP Control is set to I Frame Sync If the downstream transcoder does not support altering GOP structures set the GOP Control setting to User GOP MN This will also require the setting of the GOP structure which is given as two numbers where the first is the length of the GOP and the second is the number of B pictures per sub GOP The supported GOP structures are ...

Страница 246: ...12 2 15 2 24 2 and 30 2 6 Choose to enable or disable the 3 2 Pulldown 7 Choose the SD transcode channel output aspect ration from the Output Aspect Ratio drop down list The options are 4 3 and 16 9 wide aspect ratio The default is 4 3 Set it to the corresponding value 8 From the Aspect Ratio Conversion drop down list choose the SD transcode channel aspect ratio conversion This is the conversion t...

Страница 247: ...ption Off No subtitles are displayed On Displays DVB or Imitext subtitles if available DVB Displays only DVB titles if available Otherwise no subtitles are displayed Imitext Displays only Imitext subtitles if available Otherwise no subtitles are displayed 3 From the Select By drop down list choose the input source for the subtitle language The default is Language List Language Entry and PMT Order ...

Страница 248: ...rovider for example eng for English in the Manual Entry field The supported languages are according to ISO 639 2 Language Codes 4 From the Imitext Position drop down list choose the position of the on screen subtitle text Standard or Extended 5 The Imitext Foreground Color sets the color for Imitext subtitles Auto displays text in the color transmitted by the subtitling equipment Yellow and White ...

Страница 249: ...nscoding such as bit rate GOP and resolution to the local transcoder settings for the selected program entry This is only supported with an uplink that uses uplink transcoding controls for the user address of the selected program entry The Apply Inband Settings window is displayed 2 Check the transcoder program entry check box 3 Click OK ...

Страница 250: ...the user interface of the D9858 choose System Settings Identification The Identification page is displayed 2 The Identification page displays the parameters associated with the D9858 system such as serial number model number and user addresses 3 You may optionally change the Hostname device name and click Apply ...

Страница 251: ...t D9858 Advanced Receiver Transcoder For example it indicates whether the transcoder is equipped with an SDI output and the number of transcoding paths The Feature License Summary area displays a list of software licenses for the D9858 Advanced Receiver Transcoder and whether each of the software licenses are enabled or disabled Note All software licenses are enabled for this release temporarily A...

Страница 252: ...Data and Management ports for IP applications and upgrading application software 3 Select control or data settings and set the IPv4 Destination IP Address for the interface The Statmux port is not supported 4 Set the number of CIDR Classless Inter Domain Routing bits in the network Mask 8 to 30 5 Set the Gateway Address on the Network used to expose the transcoder to a WAN The IP Address IP Mask a...

Страница 253: ... IRD Telnet SSH HTTP HTTPS via HTTP secure setting and SNMP 1 From the Telnet SSH HTTP and SNMP drop down list choose Enable default to allow Telnet Secure Shell HTTP and or SNMP connections Otherwise select Disable The following lists the associated port numbers for each protocol Protocol Port Number Telnet TCP port 23 SSH TCP port 22 HTTP TCP port 80 HTTPS via HTTP secure setting TCP port 443 SN...

Страница 254: ...ld enter the number of seconds before the session for all the enabled protocols will timeout due to inactivity in a range from 30 to 1209600 seconds Enter zero to never timeout 3 Click Apply System Logs From the Syslog drop down list choose the logging protocol to use Syslog TCP or Syslog UDP The Legacy option is used by Cisco customer support only Select Disable to disable system logging If Syslo...

Страница 255: ...source logging system Syslog Watcher SnmpSoft for Windows http www snmpsoft com downloads html The following is an example of a syslog Viewing the Link Status The Link Status table displays the port information such as the status speed duplex and crossover Port 1 is the management port and port 2 is the data port ...

Страница 256: ...outing information is displayed in the Installed Unicast Routes table 3 Click Apply 4 In the Static Unicast Routing table you can set the static unicast routing information used to by MPEGoIP and MPE outputs to send data packets It can also be used to find hosts behind a router for example an FTP server a syslog server or an NTP server To add a unicast route a Click Add Row b In the Destination IP...

Страница 257: ...ask which will depend on the size of your network Mask Subnet Mask 8 255 0 0 0 16 255 255 0 0 24 255 255 255 0 e Check the Port 1 and or Port 2 check box The management port is port 1 and the data port is port 2 f Click Save The routing information is displayed in the Installed Unicast Routes table If the configured routing information has an inactive port then the routing information is not displ...

Страница 258: ...d All or Forward Filtered Choose Forward None to not forward MPE data to the network Choose Forward All to forward all the MPE data to the network Choose Forward Filtered to only forward the MPE data from the defined Static Multicast Filtering table below to the network For more information on configuring the Static Multicast Filtering table see To Add a Static Multicast Filtering on page 237 Note...

Страница 259: ...24 0 0 0 to 239 0 0 0 Note If MPE Data Filter Mode is set to Forward All or Forward Filtered all the unicast MPE data will be forwarded regardless of the Static Multicast Filtering table 3 Click Save To edit delete an existing multicast filter address select the address entry by clicking on the radio button Click Edit and make the necessary changes or click Delete to remove the address from the St...

Страница 260: ...is is used when communicating with a device within an SNMP environment To set a custom community string enter an alphanumeric character string up to 31 alphanumeric characters in length identifying the password for the device Note The community string is case sensitive 3 In the System Name System Location and System Contact fields enter the system name location and contact information of the D9858...

Страница 261: ... example alarms 3 Type the Community String for the trap destination IP Address entered above 4 Enter public or custom string The default is public You can enter a string up to 35 characters 5 Click Save To edit delete an existing trap destination select the trap destination entry by clicking on the radio button Make the necessary changes or click Delete to remove the address from the Trap Destina...

Страница 262: ...T Offset drop down list choose the GMT offset time The local time is displayed using a time zone GMT offset If your local time is not GMT you must set this time setting in the range from 12 0 to 12 0 hours in 0 5 hour increments 5 The Current TDT Time Date displays the current TDT Time and Date Table date and time received from the DVB stream This is displayed as local time 6 Check the Enable NTP ...

Страница 263: ...858 system The Fault Summary area displays the Type of message alarm or warning and the number of alarms and warnings that have an active status Number Active The following table shows the Alarm Warning Status table information Status Description Type Shows whether it is an alarm or a warning message Name Name of the alarm or warning For more information on alarm messages refer to D9858 Transcoder...

Страница 264: ...b GUI Setup and Monitoring 242 Status Description Text Content of the message Set Since Date and time of the alarm or warning Click Clear Alarms Warnings to clear all the messages in the Alarm Warning Status table ...

Страница 265: ...t is either cleared or the Enable Alarm Warning Front Panel Reminder is de selected 3 Check the Enable Video Cutoff on Alarm Condition check box to cut off the video output if any enabled alarm is active on the receiver When video is cut off there will be no horizontal or vertical synchronization on the output This is useful for downstream redundancy switching by detecting a loss of video signal 4...

Страница 266: ...g suppressed because the alarm is disabled Enb is set to No 8 If current alarm is enabled choose Yes from the Relay drop down list for the rear panel alarm relay to be triggered when the alarm is set or cleared Note No is a read only value that indicates the setting is Yes but is currently being suppressed because the alarm is disabled Enb is set to No 9 Click Apply To Set Up Warnings Proceed as f...

Страница 267: ...e functional 5 If current warning is enabled choose Yes from the Trap drop down list and the SNMP trap message will be sent when the warning is set or cleared Note No is a read only value that indicates the setting is Yes but is currently being suppressed because the warning is disabled Enb is set to No 6 If current warning is enabled choose Yes from the Relay drop down list for the rear panel ala...

Страница 268: ...ory The Alarm and Warning History page displays all the past system event messages and their set and cleared dates and times For more information on the alarm messages refer to D9858 Transcoder Alarm Messages on page 272 Click Clear Alarms Warnings History to clear all the messages in the Fault History table Click Export to export the alarm history to a csv file The File Download dialog box is dis...

Страница 269: ... SW Version drop down list choose a different application version number to load From the FPGA drop down list choose a different FPGA version number to load The Selected Version dialog box is displayed Click Select Reboot to load the selected application and reboot the transcoder Click Erase to remove the selected application version You will be prompted to continue or not Click OK to continue the...

Страница 270: ...XB In the APP FPGA Downloads area click Browse to select the new version of FPGA or the D9858 Advanced Receiver Transcoder s software application The Open dialog opens Select the upgrade file and click Open Click Download to download the selected upgrade file File formats that can be downloaded include application CDTs and FPGA CDTs The State field in the Download Status area displays the progress...

Страница 271: ...running on the D9858 transcoder The current and official Cisco D9858 transcoder hash values are published in the D9858 release note For more information see Cisco D9858 Advanced Receiver Transcoder Release Note If the generated hash digest values do not match the official list contact Cisco customer support To start a communication session with the transcoder use a utility such as Tera Term Pro or...

Страница 272: ...ith the values listed in the appropriate D9858 release note If the values do not match contact Cisco customer support Viewing Transcoder Version Information From the user interface of the D9858 choose System Settings Versions Transcode The Versions Transcode page is displayed The Transcode Firmware Versions table displays the version numbers applicable to the Transcoder printed circuit board ...

Страница 273: ...ng in the transcoder board MPEG 2 encoder device s Board Version Indicates the board version of the transcoder board Board Serial Number Indicates the serial number that is uniquely assigned to the transcoder board The HW Board Versions table displays the revisions option bits and serial numbers of the main board TMB The Transcode Software Versions table lists all the software packages used for th...

Страница 274: ...rmation radio button and click Export to download device settings and transport network information as a file to the designated file folder 3 Click the Export User Device Settings only radio button and click Export to download user settings as a file to the designated file folder 4 In the Settings File area click Browse The Choose File dialog opens Navigate to the appropriate folder and select the...

Страница 275: ...tailed processing step for tracking backup progress Percentage Complete Percentage of backup function completed Setting upImport Export FTPInformation 1 From the user interface of the D9858 choose System Settings Import Export FTP The Import Export FTP page is displayed 2 The Configure Offline FTP Settings File Transfer area has backup and restore controls Note You must have access to an FTP Serve...

Страница 276: ...ettings and tuning information to the backup file Click the Export User Device Settings Only radio button to save user settings to the backup file 8 Click Export to save the settings to a backup file Click Import to retrieve the last backed up file Viewing the Backup Restore Status The following table displays the Settings File Backup Restore Operation History information Status Description Last B...

Страница 277: ...User and Guest are only allowed to modify their own passwords To Change the User Login Passwords 1 From the user interface of the D9858 choose System Settings Account Management The Account Management page is displayed To configure the password complexity for all users Note This feature is only available to a user with Admin privileges only 2 From the Password Complexity drop down list choose the ...

Страница 278: ... characters Must contain a minimum of three of the following types of characters capital letters small letters digits and special characters Note The complexity level changes will only affect the new user accounts and password changes It will not affect existing passwords Any changes take effect immediately and do not require the use of the Apply button To change your login password Note You are a...

Страница 279: ...ature is available to a user with Admin privileges only 1 From the Account Management page click the Manage User Logins link The Login Accounts page is displayed 2 Click Add Account Login to create a new login account Note You can create a maximum of 10 user accounts ...

Страница 280: ...gain to confirm in the Confirm New Password field Note The New Password and Confirm New Password should be identical 6 In the Administrator Password field enter your Administrator password used to log on to the D9858 web GUI 7 From the Account Type drop down list choose User Admin or Guest The following table illustrates the different login types Account Type Access Guest View settings only User V...

Страница 281: ...gs 259 2 Click Delete Account Login The Delete Login Account dialog box is displayed 3 In the Administrator Password field enter the administrator password to confirm the deletion 4 Click OK The selected user account is deleted ...

Страница 282: ...the Lock Level drop down list choose the lock level that restricts access and prevents unauthorized changes to the receiver settings 0 1 2 or 3 The default setting is 0 Note For details on the four lock levels see D9858 Transcoder Lock Levels 4 In the Enter the Password to change the Lock Level field enter the password to change the lock level Depending on the unit the default password is 1234 For...

Страница 283: ...upport Important Proceed with caution when changing the password as this operation cannot be undone If the password is lost or is unavailable contact Cisco customer support 1 In the Lock Level Settings page click Change Lock Level Password The Change Lock Level Password window is displayed 2 In the Enter Current Password field enter the current lock level password 3 In the Enter New Password field...

Страница 284: ...ck check box to enable the front panel keypad lock state 3 The Keyboard Lock Timeout sets the keypad lock timeout period The lock timeout period takes effect when the keypad has not been touched that is a key has not been pressed when on the Main Menu for the set period Avoid setting the period to a short duration when the keypad is used often Enter a value in the range from 5 to 1800 seconds The ...

Страница 285: ...Support Information Viewing ContactInformation From the user interface of the D9858 choose Support Contact Information The Contact Information page is displayed The Contact Information page displays all the Cisco customer support information ...

Страница 286: ...page is displayed The Diagnostic Logs page displays all the system log messages with their dates and times Click the arrow next to Set Date and Time column to sort by date and time Click Export to export the log history to a csv file The File Download dialog is displayed Click Save to save the file to your local drive Click Clear to clear the log history ...

Страница 287: ...plays the number of hours since the last power on Lifetime Reset Counter Displays the total number of times the receiver has been restarted Clearable Reset Counter Displays the number of restarts since the last time the restart counter was cleared To clear or reset the Clearable Reset Count click Clear Reset Counter Hours Since Last Powered On Reset Displays the total number of hours that the rece...

Страница 288: ...mperatures page is displayed The Current column displays the current operating temperature The Maximum column displays the maximum operating temperature that has been reached The Average column displays the average operating temperature The values are displayed in Degrees Celsius The FAN1 to FAN7 columns display the current speed of the seven fans in the D9858 transcoder ...

Страница 289: ...he Alarm and Warning History page displays all the past system event messages and their set and cleared dates and times For more information on the alarm messages refer to D9858 Transcoder Alarm Messages on page 272 Click Clear Alarms Warnings History to clear all the messages in the Fault History table Click Export to export the alarm history to a csv file The File Download dialog box is displaye...

Страница 290: ...drop down list allows you to choose load a different application version to your unit Click Select Reboot to load the selected application version and reboot the transcoder Click Erase to remove the selected application version You will be prompted to continue or not Press OK to continue the deletion Click Factory Reset to perform a reset of the settings back to the factory set default values A wa...

Страница 291: ...at you interrupt the upgrade during the application download Click Download Status Toggle to move between updating the Download Status data on the Versions page and updating the download status on an external device Note For application downloads once the download is complete the D9858 transcoder will reboot automatically For FPGA downloads you must click Reboot Receiver to manually reboot the D98...

Страница 292: ......

Страница 293: ...ng firmware to the Cisco D9858 Advanced Receiver Transcoder It also describes how the status of the D9858 transcoder is communicated via front panel LEDs 6 Chapter 6 Service and Maintenance In This Chapter D9858 Transcoder Alarm Messages 272 Power Supply Replacement 327 ...

Страница 294: ...displayed in the Warning History when the messages are set or cleared respectively Note Only alarm conditions can be used to trigger rear panel relays to control external alarm equipment Warnings are not associated with relay operations We recommend that you collect the debug support data prior to contacting Cisco customer support for any D9858 issues Alarms Alarm Message Type Message Cause Remedy...

Страница 295: ... hardware failed Major 910 Sec Flash Fail Set Contact Customer Service s fail at d Cause FLASH driver operation s one of ERASE WRITE BLANK_CHECK or READ_WRITE failed on the Secondary 7109 FLASH offset d Remedy Contact Cisco Services The FLASH device hardware failed Major 920 Trans 1 Flash Fail Set Contact Customer Service s fail at d Cause FLASH driver operation s one of ERASE WRITE BLANK_CHECK or...

Страница 296: ...er Service Cause Corrupted database record was found while populating the DBR partition Remedy Contact Cisco Services The settings database detects corruption Major 950 Signal Status Set ASI Signal No Content Cause Loss of ASI RF lock Loss of Transport data Invalid frequency parameters External to IRD Remedy Check tuning parameters and ASI RF cables ASI Link Locked but no TS content Minor 1000 Sig...

Страница 297: ...invalid Minor 1000 Signal Status Clear Signal is locked Signal OK Minor 1000 Signal Status Clear Tuning Parameters Valid Tuning parameters are valid Minor 1000 Transcoder Status Set Transcode Not Started Restart Timeout Cause Possible hardware or software fault Remedy Clear all alarms reset the unit and notify Cisco Services if the problem persists No response was received from the transcoder duri...

Страница 298: ...er software Major 1500 Transcoder Status Set Transcode Not Started Encoder failed to load Cause Possible hardware or software fault Remedy Clear all alarms reset the unit and notify Cisco Services if the problem persists Unable to load or execute the encoder software Major 1500 Transcoder Status Set Transcode Not Started Invalid production information Cause Possible hardware or software fault Reme...

Страница 299: ...essages Major 1500 Transcoder Status Clear Transcoder Started Major 1500 Transcoder Verification Set Post reported errors Cause Possible hardware issue Remedy Clear all alarms reset the unit and notify Cisco Services if the problem persists The transcoder power on self test reported errors Major 1600 Transcoder Verification Set Post data unavailable Cause Possible hardware issue Remedy Clear all a...

Страница 300: ...ear Fault cleared Major 2000 PE n ISE Not Auth Set Channel is not authorized Cause The channel is unauthorized for the current program Remedy Contact your uplink service provider to determine whether you are authorized to receive the current program Program unauthorized because the tier bits do not match Minor 3000 4000 5000 6000 7000 8000 9000 10000 10009 10032 PE n ISE Not Auth Set Channel requi...

Страница 301: ...e authorized to receive the current program at this time Non SA conditional access system Minor 3000 4000 5000 6000 7000 8000 9000 10000 10009 10032 PE n ISE Not Auth Set Channel authorization refused Cause Conditional access not supported Remedy Contact your uplink service provider to determine whether you are authorized to receive the current program at this time There is mismatch in the Conditi...

Страница 302: ...nfiguration issue Remedy Contact your uplink service provider to determine whether the LEC GDS data is being provided in the stream LEC tables are no longer present in the transport stream Minor 3000 4000 5000 6000 7000 8000 9000 10000 10009 10032 PE n ISE Not Auth Clear Fault Reset Minor 3000 4000 5000 6000 7000 8000 9000 10000 10009 10032 PE n ISE Not Auth Clear Channel is authorized Minor 3000 ...

Страница 303: ...corruption in the stream Minor 19000 Digital Program Mapping Set Program Collision Cause Uplink settings may have changed since setting up the unit Please check your DPM settings Remedy Correct the DPM settings Check the uplink to find the appropriate system settings Two source channel numbers are being mapped passed to the same channel number in the output Minor 19000 Digital Program Mapping Set ...

Страница 304: ...ranscoder Minor 19500 Transcoding Status Set Transcoding Halted Transcoder out of sync Cause Possible hardware or software issue Remedy Reselect desired application clear alarms reset the unit notify Cisco Services if problem persists Transcoder software in unexpected state Minor 19500 Transcoding Status Clear Transcoding operational Minor 19500 Shutdown Event Set DL APP REBOOT Cause User request ...

Страница 305: ...al system error fault clear alarms reset the unit notify Cisco Services if the problem persists Runnable application change requires reboot Major 20000 Shutdown Event Set User requested factory reset Cause User request requires reboot or internal system error Remedy If it is an internal system error fault clear alarms reset the unit notify Cisco Services if the problem persists Factory reset requi...

Страница 306: ...Protect Flash Cause User request requires reboot or internal system error Remedy If it is an internal system error fault clear alarms reset the unit notify Cisco Services if the problem persists Reboot after production tables removed Major 20000 Shutdown Event Set I2C Failure Cause Possible software hardware issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Internal sy...

Страница 307: ...ftware issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set NVS FLASH mounted Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set DB_Table_Cl popu lateNvsRecords Cause Possible software issue Rem...

Страница 308: ...ftware issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set DB_FlagArray32_C l init failed Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set Wrong DB Item detected item AAA table BBB Cause Poss...

Страница 309: ...tems Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set DBT Init Failed AAA Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set Framework Registration Error Cause Possib...

Страница 310: ...e Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set Memory allocation error on UIC table construction Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set Error adding UIC tab...

Страница 311: ...System Partition Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set UD ud_init_phase_4 FAILED to create partition Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set COM...

Страница 312: ... Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event Set UIC_ENUM_CL given invalid ENUM_ST item AAA table BBB problem with primary X Cause Possible software issue Remedy Clear alarms reset unit notify Cisco Services if problem persists Application initialization error Major 20000 Shutdown Event...

Страница 313: ...ervices if problem persists Indicates that the decoder has started up This alarm will clear itself after one second Major 20100 SMI Setup Set Phase lock error on SMI SDRAM Cause Hardware Issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists SDRAM on SMI bus not working Major 21000 SMI Setup Set SMI SDRAM exhaust test failed Cause Hardware Issue Remedy Clear ala...

Страница 314: ...m persists Non volatile storage system failed to update fully Major 23000 Param Storage Set RAM flush to NVS failed Cause Hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists Non volatile storage system failed to update fully Major 23000 Param Storage Set DB Factory Reset in progress Cause Standard operation Remedy Clear alarms reset the unit and noti...

Страница 315: ... operation in progress Major 23000 Param Storage Set DB Factory Reset failed Cause Hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists Non volatile storage system failed during operation Major 23000 Param Storage Set DB Total Reset failed Cause Hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists Non vol...

Страница 316: ...leted Non volatile storage system operation successful Major 23000 Param Storage Clear DB NVS flush completed Non volatile storage system operation successful Major 23000 Param Storage Clear DB Populate completed Non volatile storage system operation successful Major 23000 Flash Storage Set RECORD init failed Cause Hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the ...

Страница 317: ...if the problem persists LNB power overload Minor 25000 LNB PS Set LNBPS Over Temperature Cause Possible wiring or hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists LNB power overload Minor 25000 LNB PS Set LNBPS Over Loaded Cause Possible wiring or hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists L...

Страница 318: ... during a lifetime Remedy Check if the desired application is running and if the settings are valid FLASH recovered after unexpected corruption Minor 25500 Signal Quality Set Audio Muted due to RF noise Cause RF Signal quality is poor due to interference or signal level issues Remedy Check RF settings re aim dish and add signal amplifier Signal is locked but BER is beyond Audio muting threshold Mi...

Страница 319: ...are issue Remedy Clear alarms reset unit and notify Cisco Services if problem persists Programmabl e transport input module stopped processing any data packet Minor 27000 Transport Processing Clear PTI running Minor 27000 Version Mismatch Set Version Mismatch between 5514 7109 Cause The App5514 version does not match the App7109 version Remedy Download code with identical App5514 and App7109 versi...

Страница 320: ...NVS Flash Failure Set APP SAT7109 PP C CRC Write has Failed Cause Possible hardware or software issue Remedy Clear alarms reset unit and notify Cisco Services if problem persists Failed to read or write flash memory Major 27600 DL NVS Flash Failure Set TEB Flash Write Failed Cause Possible hardware or software issue Remedy Clear alarms reset unit and notify Cisco Services if problem persists Faile...

Страница 321: ... too high or air flow is blocked Remedy Check openings on front and rear panels for blockage Lower room temperature or improve air flow to device FPGA temperature is above safe operating range Major 30000 FPGA Temperature Alarm Clear Temperature normal 30000 TEB FPGA Temper Alarm Set Temperature over Alarm threshold Cause Room temperature too high or air flow is blocked Remedy Check the openings o...

Страница 322: ...afe operating range Major 32000 TEB ENC1 Temper Alarm Clear Temperature normal TEB encoder 1 temperature is within the safe operating range Major 32000 TEB ENC2 Temper Alarm Set Temperature over Alarm threshold Cause Room temperature is too high or air flow is blocked Remedy Check the openings on the front and rear panels for blockage assess the room temperature Lower the room temperature or impro...

Страница 323: ...configured rate for ASI output Output has been muted to protect downstream devices Minor 34000 ASI Out Status Clear ASI Output Restored Minor 34000 MPoIP Status Set MPEGoIP Overflow Output Muted Reduce content Cause Uplink settings may have changed since setup of the unit Variable Bit Rate Statmuxed streams may be in use Remedy Increase output rate drop unreferenced content in DPM Options drop pro...

Страница 324: ... Hardware issue Remedy Clear alarms reset unit and notify Cisco Services if the problem persists Flash memory not detected Major 36000 Boot Host Set EMI SDRAM Test Failed Cause Hardware issue Remedy Clear alarms reset unit and notify Cisco Services if the problem persists RAM Failure memory testing failed Major 36000 Boot Host Set BOOT Invalid Cause Hardware issue Remedy Clear alarms reset unit an...

Страница 325: ...ondary Set APP Invalid Cause Hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists Application SW cannot be read from memory correctly Major 37000 Boot Secondary Clear BOOT passed Major 37000 Decoder Processor Start Set DB Startup failed Cause Hardware issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists Transfer o...

Страница 326: ...navailable Cause Possible LEC Server or Uplink issue Remedy Check LEC Server setup and the uplink configuration for the GDS PID setup Clear alarm and notify Cisco Services if problem persists ECT Table is not received in the GDS stream Major 38500 LEC Timeout Clear LEC received Major 38500 FPGA status Set FPGA Init failed to go high Cause Hardware issue Remedy Clear alarms reset the unit notify Ci...

Страница 327: ...e upper or lower limit Cause Hardware issue Remedy Clear alarms reset the unit notify Cisco Services if the problem persists FPGA setup failure or the FPGA binary identity does not match the FPGA registers Major 39000 FPGA status Set FPGA ID does not match FPGA DESIGNATION Cause Hardware issue Remedy Clear alarms reset the unit notify Cisco Services if the problem persists FPGA setup failure or th...

Страница 328: ...he current channel assigned to this Program Entry is scrambled using an unsupported CA System Remedy Check to ensure that the proper channel is assigned to this Program Entry CA System present in the currently selected channel cannot be descrambled due to no PowerVu ISE support Minor 93000 93031 PE n CA System Error Clear Fault cleared Minor 93000 93031 D R in Progress Set Disaster declared Cause ...

Страница 329: ...tion matches the NIT An invalid NIT is received and the unit fails to lock acquire the NIT signal Major 980 NIT Retune Recovery Clear Alarm cleared The error is cleared when another valid NIT is received and the signal is locked and acquired or the incorrect configuration is resolved Major 980 Warnings Warning Message Type Message Cause Remedy Description ID Transcoding Condition Set Transcoding E...

Страница 330: ... configuration message 39500 Transcoding Condition Set Transcoding configuration error socket error Cause Possible software issue Remedy Clear alarms reset the unit and notify Cisco Services if the problem persists Unable to send the configuration to the transcoder 39500 Transcoding Condition Set Transcoding configuration error refused Cause Possible software issue Remedy Clear alarms reset the un...

Страница 331: ...t Variable bit rate or statmuxed streams may be in use Remedy Increase the output rate drop unreferenced content in DPM Options and drop the programs that are not needed for downstream devices Contact your uplink service provider to verify the expected bit rate settings The output rate is higher than level set by the user 40000 ASI TS Overflow Clear ASI Output Overflow Cleared 40000 Transport Erro...

Страница 332: ...ransport Rate Error FPGA Overflow Cause Uplink settings may have changed since setting up the unit Remedy Increase the output rate drop unreferenced content in DPM Options and or drop programs not needed for downstream devices Contact your uplink service provider to verify the expected bit rate settings The output rate is higher than level set by the user 42000 Transport Error Clear Continuity Cou...

Страница 333: ...flow is blocked Remedy Check the openings on front and rear panels for blockage Lower the room temperature or improve air flow to the device FPGA temperature is above normal operating range 45000 FPGA Temperature Warning Clear Temperature normal FPGA temperature is within the normal operating range 45000 TEB FPGA Temper Warning Set Temperature over Warning threshold Cause Room temperature too high...

Страница 334: ...n the normal operating range 47000 TEB ENC2 Temper Warning Set Temperature over Warning threshold Cause Room temperature is too high or air flow is blocked Remedy Check the openings on the front and rear panels for blockage assess the room temperature Lower the room temperature or improve air flow to the device TEB encoder 2 temperature is above the safe operating range 48000 TEB ENC2 Temper Warni...

Страница 335: ...if not using the table No longer receiving Time Date 50000 TDT timeout Clear TDT fault cleared 50000 SDT timeout Set SDT timed out Cause Uplink is not sending or is sending intermittently Remedy Clear warning If the problem persists determine if uplink is sending the current SI information table Disable the warning if not using the table Service Description Table was never received 51000 52000 530...

Страница 336: ...isable the warning if not using the table Program Mapping Table was never received 59000 60000 61000 62000 63000 64000 65000 66000 66009 66031 PMT timeout Set PMT is lost Cause Uplink is not sending or is sending intermittently Remedy Clear warning If the problem persists determine if uplink is sending the current SI information table Disable the warning if not using the table No longer receiving ...

Страница 337: ... or is sending intermittently Remedy Clear warning If the problem persists determine if uplink is sending the current SI information table Disable the warning if not using the table No longer receiving Program Association Table 67000 68000 69000 70000 71000 72000 73000 74000 PAT timeout Clear PAT fault cleared 67000 68000 69000 70000 71000 72000 73000 74000 NIT timeout Set NIT timed out Cause Upli...

Страница 338: ...ne if uplink is sending the current SI information table Disable the warning if not using the table Conditional Access Table was never received 76000 CAT timeout Set CAT is lost Cause Uplink is not sending or is sending intermittently Remedy Clear warning If the problem persists determine if uplink is sending the current SI information table Disable the warning if not using the table No longer rec...

Страница 339: ... is sending the current SI information table Disable the warning if not using the table Inband Control Table was never received 77100 MCT Timeout Set MCT is lost Cause Uplink is not sending or is sending intermittently Remedy Clear warning If the problem persists determine if uplink is sending the current SI information table Disable the warning if not using the table No longer receiving Inband Co...

Страница 340: ...sists SW exceeding allowable memory usage 78000 Memory Usage Host Clear Normal stack partition memory usage 78000 Memory Usage Secondary Set Excessive stack partition memory usage Cause Possible software issue Remedy Clear warnings reset the unit and notify Cisco Services if the problem persists Software exceeding allowable memory usage 79000 Memory Usage Secondary Clear Normal stack partition mem...

Страница 341: ...000 83000 Ethernet Port n Clear Connection OK 81000 82000 83000 FW Resource Use Host Set Memory or List Near Full Cause Possible software issue Remedy Clear warnings reset the unit and notify Cisco Services if the problem persists Software exceeding allowable usage of internal constructs 86000 FW Resource Use Host Clear Normal Level 86000 FW Resource Use Second Set Memory or List Near Full Cause P...

Страница 342: ...d to connect to server or transfer file 89000 Backup Failure Reason Set Internal Error Cause Possible software issue Remedy Clear warnings reset the unit notify Cisco Services if problem persists Backup ran out of memory or other internal error 89000 Restore Failure Reason Set FTP Failed Cause FTP settings or the server may not be configured correctly Remedy Verify the FTP server configuration and...

Страница 343: ...e correct import file is being used and was created by this product Verify that the file structure has not been corrupted If the problem persists notify Cisco Services Item in import file is not valid for this software and import did not occur 89100 MPoIP Bitrate Port n Set Total configured output is marginal or too high Cause The aggregated MPEG over IP bandwidth on Port n is too high Remedy Re c...

Страница 344: ...inal Network ID in NIT and SDT mismatched Cause The NIT and SDT have different original network IDs Remedy Additional error details are displayed in the log file Ensure that the uplink is sending the same original network ID in SDT and in NIT The original network ID in NIT does not match the original network ID in SDT 98000 Network ID Mismatch TS1 Clear Original Network ID in NIT and SDT matched T...

Страница 345: ...link profile Contact your PNC uplink administrator The Disaster Recovery Table received from uplink is invalid 99320 D R Malformed DRT Clear DRT accepted The error is cleared before disaster recovery search path is generated 99320 D R No DRT Received Set No DRT Received Cause Did not receive the Disaster Recovery Table from the uplink Remedy Ensure that a valid Disaster Recovery Table is received ...

Страница 346: ...that are described in the exported diagnostics file Support Service Actions For more information see Loading a Software Version and License on page 268 99340 D R Invalid Tuning Clear warning cleared The error is cleared before re validating the tuning 99340 D R Invalid L Band Set Invalid calculated L band frequency for Backup list of affected D R Backup Transports Cause Calculation of the L Band f...

Страница 347: ...eived from the uplink is invalid 99360 D R Value Out of Range Clear cleared The error is cleared before re validating tuning 99360 D R Rolloff Invalid Set Rolloff factor invalid for DVB for Backup list of affected DR Backup Transports Cause The selected Rolloff factor value for the identified Backup Transport is not valid for the selected DVB system Remedy Contact your PNC uplink administrator to ...

Страница 348: ... RF Input settings is in conflict with the calculated L Band frequency of the Backup Transport s that use that RF Input Remedy Contact your PNC uplink administrator to check the tuning parameters and RF Input LO frequencies for the identified disaster recovery backup transports The Disaster Recovery Table received from the uplink is invalid 99380 D R LO Freq Mismatch Clear cleared The error is cle...

Страница 349: ...Power Supply Replacement There are no user serviceable parts in the D9858 transcoder power supply If the power supply requires replacement contact your service provider or Cisco for information on how to return the unit for repair ...

Страница 350: ......

Страница 351: ...options to speak with a service engineer Access your company s extranet site to view or order additional technical publications For accessing instructions contact the representative who handles your account Check your extranet site often as the information is updated frequently 7 Chapter 7 Customer Information ...

Страница 352: ......

Страница 353: ... for the Cisco D9858 Advanced Receiver Transcoder Note The technical specifications are subject to change without prior notice In This Appendix L Band Input and Processing 332 Video Inputs Outputs and Processing 336 Transport Stream Outputs 341 Control Management and Data Interfaces 343 Power and General Specifications 345 ...

Страница 354: ... and 8PSK Number of RF Inputs 4 only one active at a time LNB LOStability DVB S and DVB S2 Symbol Rate Stability 1 to 4 99 MSymbols s 125 kHz 5 0 to 9 99 MSymbols s 1 0 MHz 10 0 to 45 MSymbols s 3 0 MHz Parameter Specification LNB Phase Noise Requirement 35 dBc Hz at dF 100 Hz 53 dBc Hz at dF 1 kHz 76 dBc Hz at dF 10 kHz 96 dBc Hz at dF 100 kHz 106 dBc Hz at dF 1 MHz 117 dBc Hz at dF 10 MHz ...

Страница 355: ...iver Parameter Specification L Band Input Number of Inputs 4 one active at a time Input Connector Type F type female 75 ohms Input Impedance 75 ohms Return Loss 10 dB Isolation Between Inputs 40 dB L band Frequency 950 to 2150 MHz Tuning Step Size 1 MHz Receive Spectrum Sense Normal and Inverted L Band Power Input Power Level per Carrier 25 to 65 dBm full transponder power DVB S Modulation EN 300 ...

Страница 356: ...ximum Channel Bit Rate 90 Mb s Maximum User Bit Rate 78 55 Mb s DVB S Eb No C N Ratio Convolutional FEC Rate Eb No Ratio dB in Linear Channel and IF Loop configuration C N at DVB Threshold BW Symbol Rate 1 2 4 5 4 1 2 3 5 0 5 9 3 4 5 5 6 9 5 6 6 0 7 9 7 8 6 4 8 5 C N Eb No 10 log 2 x FEC X 188 204 The D9858 transcoder displays the C N Ratio DVB S2 Error Rate Performance Es No C N Ratio Mode Simula...

Страница 357: ...me length 64 800 Typical Performance dB in Linear Channel and IF Loop configuration QPSK 4 5 4 68 4 8 QPSK 5 6 5 18 5 3 QPSK 8 9 6 20 6 4 QPSK 9 10 6 42 6 6 8PSK 3 5 5 50 5 8 8PSK 2 3 6 62 6 8 8PSK 3 4 7 91 8 1 8PSK 5 6 9 35 9 6 8PSK 8 9 10 69 10 9 8PSK 9 10 10 98 11 3 ...

Страница 358: ...umber of Channels 1 Compression Format MPEG 4 AVC V Resolutions 1080 720 Horizontal Video Resolutions 1080i 1920 1440 720p 1280 960 Bit Rate 3 Mb s to 20 Mb s Main Profile 3 Mb s to 25 Mb s High Profile Connector BNC 75 ohms Video Outputs Item Specification Transcoder Channel Outputs HD Video Output Number of Channels 1 Compression Format MPEG 2 Vertical Resolutions Same as input Horizontal Resolu...

Страница 359: ...1 1 Bar Tilt NTC 7 comp 0 5 0 5 Sync Level NTC 7 comp 40 IRE 0 5 IRE 40 IRE 2 0 IRE DC Offset NTC 7 comp 100 mV 100 mV Chrominance to Luminance Gain Inequality NTC 7 comp 100 5 100 5 Chrominance to Luminance Phase Inequality NTC 7 comp 20 ns 20 ns K factor K 2T NTC 7 comp 1 1 Jitter 5 ns 5 ns Frequency Response FCC multi burst 0 5 MHz 0 dB 1 25 MHz 0 dB 0 2 dB 2 MHz 0 dB 0 2 dB 3 MHz 0 dB 0 3 dB 3...

Страница 360: ...S17 700 mV 7 mV 1 700 mV 35 mV 5 Line Time Distortion VITS17 1 1 Bar Tilt VITS17 0 5 0 5 Sync Level VITS17 300 mV 3 mV 300 mV 15 mV DC Offset VITS17 100 mV 100 mV Chrominance to Luminance Gain Inequality Colour Bars 100 5 100 5 Chrominance to Luminance Phase Inequality Colour Bars 20 ns 20 ns K factor K 2T VITS17 1 1 Jitter 5 ns 5 ns Frequency Response VITS18 0 5 MHz 0 dB 1 MHz 0 dB 0 2 dB 2 MHz 0...

Страница 361: ...0 MHz 30 dB AudioInputs Outputs Analog SD Video Output CVBS1 and CVBS2 for monitoring Item Specification Number of Channels One down converted source HD program Video Decompression Type MPEG 2 4 2 0 Output Level 1 0 Vpp 5 Output Impedance 75 ohms Analog Audio Inputs Item Specification Number of Channels 2 Audio Decompression MPEG or Dolby Digital AC 3 Analog Audio Outputs Item Specification Number...

Страница 362: ...Appendix A Technical Specifications 340 VBI Data Input Output Item Specification Transmission Format EIA 708 and EIA 608 ...

Страница 363: ...ss 17 dB 27 to 270 MHz Transport stream bit rate 1 to 80 Mbps ASI bit rate 200 Mbps 100 ppm Transport stream formats According to EN 50083 9 188 bytes structure Burst or packet format MPEGoIP Output Item Specification Number of outputs 1 Type of connector RJ 45 10 100 1000BASE T Output modes UDP RAW RTP IP Addressing Multicast Unicast TS Streaming MPTS TS Bit Rate 1 to 80 Mbps MPEGoIP bit rate Up ...

Страница 364: ...chnical Specifications 342 Item Specification Type of connector RJ 45 10 100 1000BASE T Output modes IPv4 datagrams IP Addressing Multicast Unicast TS Input up to 5 PIDs Bit Rate up to 10 Mbps for 1500 byte packets ...

Страница 365: ...connectors 1 Type of connector Eight pin RJ 45 Ethernet type 10 100 1000BASE T Required setup IP address default gateway and subnet mask RS 232 Data Interface Item Specification Connector type 9 pin sub D female Data rates RS 232 asynchronous data at selectable rates up to 38 4 kb s 300 1200 2400 4800 9600 19 200 38 400 b s Alarm Interface Item Specification Number of outputs 3 each having one set...

Страница 366: ... AC 30 V DC Max current 1 A ContactClosure Interface Item Specification Connector type 9 pin sub D female Minimum duration of event guaranteed to be detected 250 ms 1 frame period for example for 1080i 25 Hz 40 ms for DPI applications Max on generator impedance 100 ohms Min off generator impedance 100 kilohms ...

Страница 367: ...320 style C14 appliance receptable AC input 100 to 240 V AC 50 60 Hz Power 110 W max Power Quality ANSI IEEE Std C62 41 1 2002 Power To operate the receiver you must connect it to an AC power source WARNING Make sure that at least one end of the power cable s remains easily accessible for unplugging if you need to switch off the unit For example Ensure that the socket outlet is installed near the ...

Страница 368: ...Specification Storage General The product is within the original packaging Humidity 5 95 non condensing Temperature 20 70 C 4 to 158 F Operation Humidity non condensing 95 humidity is valid up to 40 C 91 humidity is valid up to 45 C 70 humidity is valid up to 50 C Temperature 0 C 50 C 32 F to 122 F Altitude Operating 10 000 ft 3048 m max Non operating 30 000 ft 9144 m max ...

Страница 369: ...Lock Levels Introduction This appendix lists the factory default settings and the lock levels for the Cisco D9858 Advanced Receiver Transcoder In This Appendix Factory Default Settings and Lock Levels 348 DPM Default Settings for Different Output Modes 361 ...

Страница 370: ...actory Reset Password options and transcoder parameters 2 All settings are unlocked except RF and ASI Input Tuning parameters 3 All settings locked access via password only except IP address and RF power 4 All settings locked can be changed via PNC uplink signal only If a change made to the current Lock Level setting is not saved the previously saved setting is restored Note The user cannot select...

Страница 371: ...ock Level ASI Active No 1 Tune Mode Basic 1 CA Ctl STD 1 Select UserCfg 1 RFInput Parameter Default Lock Level RFx Active RF1 is Act RF2 to RF4 is No 1 Tune Mode Basic 1 CA Ctl Std 1 Select UserCfg 1 LO1 GHz 5 15 1 LO2 GHz 0 0 1 Crossover GHz 0 0 1 OrbPos 0 0 1 E W NA 1 Pol H horizontal 1 Freq GHz 3 449 1 Sym Rate 28 3465 MS s 1 FEC Auto 1 LNB Type C Band 1 Modulation DVB S 1 ...

Страница 372: ... Service List Mode Rigorous 1 Frequency Tuning NIT 1 Use BAT in Service List No 1 Use NIT in Service List Yes 1 Use SDT in Service List Yes 1 Use PAT in Service List Yes 1 Disaster Recovery Global Parameter Default Lock Level D R Enable Yes 1 D R Profile Local 1 Signal Loss Timer 120 1 Signal Lock Timer 30 1 Verify Timer 60 1 Backup Channel The default is 0 and the lock level is 1 ...

Страница 373: ...A factory reset does not change the IP settings Parameter Default Lock Level Port ID 1 3 V4 V6 IPv4 N A IP Address 192 131 244 6 3 Mask 24 3 Gateway 255 255 255 0 3 Phy Mode Auto 3 MAC Address 00 00 00 00 00 00 N A SNMP Read Community String public 3 SNMP Write Community String public 3 SNTP Server 0 0 0 0 3 SNTP Enable No 3 Password Complexity Full Complexity Checking N A Reset Credentials N A 0 ...

Страница 374: ...rameter Default Lock Level Telnet Disable 3 SSH Disable 3 HTTP Enable 3 SNMP Disable 3 MPE Fwd All 3 Syslog Disable 3 Syslog Server 0 0 0 0 3 Port 514 3 Video Parameter Default Lock Level PV Format SD 2 SD Format Auto 2 Alarm Video Cutoff Disable 2 OSD Messages Enable 2 TV A R 4 3 2 Convert None 2 WSS Mode Passthrough 2 Enable Banner Display Web GUI only Enable 2 ...

Страница 375: ...Order 2 Language List eng 2 PMT Source AUD1 for Audio 1 and AUD2 for Audio 2 2 Entry eng 2 Captions Parameter Default Lock Level Preferred Mode Auto 2 VBI Parameter Default Lock Level WSS Mode Passthrough 2 WSS Stat Undefined N A VITS PAL Line 17 18 330 331 Disable 2 Subtitles Parameter Default Lock Level Op Mode Off 2 Select Language By Language Entry 2 Language List eng 2 ...

Страница 376: ... 2 BackGnd Auto 2 Decode Parameter Default Lock Level Decoder N A 2 Enabled Yes 2 Note By default all the decode services are enabled Cueing Parameter Default Lock Level Cueing Mode Trigger 4 Trigger Polarity High 4 Repeat 3 4 Tone ms 40 4 Silence ms 40 4 Seq 1 4 State Disable 4 Tones 0 4 Mode 4 Delay sec 1 4 Relay Mode Alarm 4 Cue Trigger Bit 1 4 ...

Страница 377: ...ed 2 Insert Null Packet Yes 2 Auto Map Yes N A Auto Map Aux No N A TS Out MOIP Parameter Default Lock Level Name MOIP N A Rate Control User 2 User Rate 0 2 Output Mode No Output 2 Descramble Mode Descrambled 2 Insert Null Packet Yes 2 Auto Map Yes N A Auto Map Aux No N A MOIP Streams Parameter Default Lock Level User Rate 68 5 Mbps 2 Intf Mode None 2 TS IP 7 2 PCR IP Start No 2 MOIP UDP 2 ...

Страница 378: ...ne 2 SAP Address 224 2 127 25 2 SAP Port 9875 2 SAP ID User String 2 SAP User Str Cisco Default SAP1 2 DPM ASI Parameter Default Lock Level PE PE1 N A Act Drop 2 StType N A 2 OutCh 0 2 PMT 8191 2 OType UNKN 2 In N A 2 PID 0 2 Map Mode SVC ID PID 2 Duplic Mode Pkt Copy 2 Unref Drop 2 PSI Options Drop All 2 PSI Rate SA Std 2 Service ID Valid Ch 2 PAT Pass 2 CAT Pass 2 ...

Страница 379: ...ass 2 TDT Pass 2 RST Pass 2 TOT Pass 2 DIT Pass 2 SIT Pass 2 ECM Pass 2 EMM Pass 2 DRT Pass 2 CDT Pass 2 TranscodeMenu Parameter Default Lock Level PE PE1 N A Video Mode HD Output 0 HD HRes Full 0 SD HRes 720 0 HD SD B R Mode CBR 0 HD Bitrate 16 Mb s 0 SD Bitrate 4 0 Mb s 0 HD SD GOP Control User GOP MN 0 HD SD User GOP MN 15 2 0 HD SD 3 2 Pulldown Disabled 0 ...

Страница 380: ...I Action Black Output 2 Inband Parameter Default Lock Level PE PE1 N A Apply Inband No 0 Options Parameter Default Lock Level Output 1 N A Fixed Output No N A Use Inp Chan No N A Start 1 N A Step 1 N A Use Inp PMT No N A Start 1701 N A Step 1 N A Use Inp PIDs No N A Start 101 N A Step 100 N A Use Inp Ord Yes N A PCR 1 N A VID 1 N A AUD 8 N A SUBT 8 N A ...

Страница 381: ...Warning Parameter Default Lock Level FP Alarm Reminder Enable 2 Alarm Vid Cutoff Disable 2 Enb N A 2 Rly N A 2 Trp N A 2 Noise Cutoff Parameter Default Lock Level Trnsprt DVB S DVB S2 Marg Cutoff 0 0 2 Trnsprt DVB S DVB S2 Marg Restore 0 1 2 Audio DVB S DVB S2 Marg Cutoff 0 0 2 Audio DVB S DVB S2 Marg Restore 0 1 2 Muting Control Enable 2 Restore Defaults N A 2 ...

Страница 382: ...lt Settings and Lock Levels 360 Import Export WebGUI only Parameter Default Lock Level Settings File Name file name 3 FTP Server IP Address 192 168 0 100 3 FTP Port Number 21 3 FTP User Name user 3 FTP Password USER 3 ...

Страница 383: ...ssthrough MAP Svc Chans Only Full DPM Control Transcoding Rate Control Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged User Rate Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Descramble Mode Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Any unchanged Descrambled Regenerate ...

Страница 384: ... it is set to Pass Actual Value Regen PMT Not Displayed If Descramble Mode is set to Descrambled it is set to Regen otherwise it is set to Pass If Descramble Mode is set to Descramble d it is set to Regen otherwise it is set to Pass Regen Regen Actual Value Regen TSDT Not Displayed Pass Pass Pass Pass Actual Value Pass NIT Not Displayed Pass Regen Regen Regen Actual Value Regen NITO Not Displayed ...

Страница 385: ...DT Not Displayed Pass Pass Pass Pass Actual Value Pass RST Not Displayed Pass Pass Pass Pass Actual Value Pass TOT Not Displayed Pass Pass Pass Pass Actual Value Pass DIT Not Displayed Pass Pass Pass Pass Actual Value Pass SIT Not Displayed Pass Pass Pass Pass Actual Value Pass ECM Not Displayed Pass Pass Pass Pass Actual Value Drop EMM Not Displayed Pass Pass Pass Pass Actual Value Drop DRT Not D...

Страница 386: ......

Страница 387: ...er Appendi xC Compliance Introduction This appendix contains the compliance information for the Cisco D9858 Advanced Receiver Transcoder In This Appendix Applicable Standards and Notices 366 Declaration of Conformity 368 ...

Страница 388: ... US UA and Group Differences as posted at the following IECEE CB Website http members iecee org iecee ieceemembers nsf ESD Electrostatic Discharge ESD results from the static electricity buildup on the human body and other objects This static discharge can degrade components and cause failures Take the following precautions against electrostatic discharge Use an anti static bench mat and a wrist s...

Страница 389: ...ected 4 Contact your dealer reseller or an experienced radio TV technician for help The user may find the booklet Interference handbook prepared by the Federal Communications Commission helpful This booklet is available from the U S Government Printing Office Washington DC 20402 stock no 004 000 00450 7 Shielded cables should be used to interconnect this device with any other peripheral equipment ...

Страница 390: ...Appendix C Compliance 368 Declarationof Conformity ...

Страница 391: ...l Settings 199 Configuring Open collector Outputs 29 Configuring System Settings 228 Configuring the ASI Output 189 Configuring the Disaster Recovery Settings 157 Configuring the DPM MPEGoIP Output Details 212 Configuring the MPE Settings 236 Configuring the MPEG over IP Stream 209 Configuring the MPEGoIP Output 203 Configuring Transcoder Settings 222 Configuring Transport Stream Information 189 C...

Страница 392: ...nel Operation 33 G General 127 332 336 345 Global 124 Global Status 53 55 Grounding 21 H Health Monitor 135 I Import Export WebGUI only 360 Inband 115 358 Installation 19 Installing the D9858 Transcoder 21 Introduction 1 IP 70 351 K Key Features 2 Keypad 34 L L Band Input and Processing 332 LCD 34 LCD Panel 39 LCD Symbol 40 Licenses 128 Link Status 53 LNB LO Stability 332 LNB Power and Control 333...

Страница 393: ...hronization Options 192 Setting up the ASI Output 16 Setting Up the MPEG over IP Auto Synchronization Options 207 Setting up the RF Input 145 Setting Up the Subtitle Burn In 225 Setting up the Video Parameters 175 Setting Up Transcoding 114 Setup Menu 57 Alarm Warning 120 DR 123 IP 69 Noise Cutoffs 121 Shortcuts 139 Software Update 4 Starting a Telnet SSH Session 30 Startup Screen 39 Status Menu 4...

Страница 394: ... Status 194 Viewing the ASI Output Transport Status 202 Viewing the Disaster Recovery Status 161 Viewing the Link Status 233 Viewing the MPEG Output Transport Status 219 Viewing the MPEG over IP Output Status 211 Viewing the System Identification 228 Viewing Transcoder Version Information 250 VITC 84 VITS 84 W Warnings 307 Web GUI Setup and Monitoring 137 Window Buttons 144 WSS 84 ...

Страница 395: ......

Страница 396: ...87 Fax 408 527 0883 This document includes various trademarks of Cisco Systems Inc Please see the Notices section of this document for a list of the Cisco Systems Inc trademarks used in this document Product and service availability are subject to change without notice 2014 Cisco and or its affiliates All rights reserved November 2014 ...