Cisco ONS 15530 Overview

The Cisco ONS 15530 is a modular and scalable optical switching and
aggregation platform designed to supplement the Cisco ONS 15540 ESP. With the
Cisco ONS 15530, users can take advantage of the availability of dark fiber to
build a common infrastructure that supports data, SAN (storage area network),
and TDM (time-division multiplexing) traffic. For more information about
DWDM technology and applications, refer to the Introduction to DWDM
Technology 
publication and the Cisco ONS 15530 Planning and Design Guide.

The Cisco ONS 15530 is designed to meet or exceed stringent ISP (Internet
service provider) requirements for product availability and reliability.

Note

Before you install, operate, or service the system, read the Regulatory
Compliance and Safety Information for the Cisco ONS 15500 Series 
for important
safety information you should know before working with the system.

This chapter includes the following sections:

Cisco ONS 15530 Chassis, page 1-1

Cisco ONS 15530 Components, page 1-11

Cisco ONS 15530 Chassis

The Cisco ONS 15530 is available in two configurations. Both have two vertically
stacked half-height slots specifically for the optical OADM (optical add drop
multiplexing) modules, and 10 vertically oriented slots that hold the CPU switch

Содержание ONS 15530

Страница 1: ... the Cisco ONS 15530 Planning and Design Guide The Cisco ONS 15530 is designed to meet or exceed stringent ISP Internet service provider requirements for product availability and reliability Note Before you install operate or service the system read the Regulatory Compliance and Safety Information for the Cisco ONS 15500 Series for important safety information you should know before working with t...

Страница 2: ...0 240V 8 0 3 5A 50 60HZ GOOD S TA TU S T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X 15530 LCMB 0200 0 1 2 3 4 5 6 7 8 9 S TA TU S T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X 15530 LCMB 0200 0 1 2 3 4 5 6 7 8 9 S TA TU S T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X 15530 LCMB 0200 0 1 2 3 4 5 6...

Страница 3: ...530 CHAS E chassis are 14 4 x 17 3 x 10 1 inches H x W x D See Figure 1 2 Handles for lifting the chassis are located on the sides Figure 1 2 Cisco ONS 15530 CHAS E Chassis The fan assembly draws in cooling air through the air ramp baffle see Figure 1 3 on the bottom of the chassis pushing the air across the internal components and out the exhaust baffles on the top of the chassis 77080 F A N S T ...

Страница 4: ...allation Guide 78 14228 02 The air ramp baffle for the Cisco ONS 15530 CHAS E chassis redirects the cooling air intake as shown in Figure 1 4 The air ramp baffle must be installed when installing the Cisco ONS 15530 CHAS E type chassis Figure 1 3 Cisco ONS 15530 CHAS E with Air Ramp Baffle 77825 F A N S T A T U S ...

Страница 5: ... the Cisco ONS 15530 CHAS N chassis are 14 4 x 15 7 x 10 1 inches H x W x D See Figure 1 5 Handles for lifting the chassis are located on the top The fan assembly draws in cooling air through the intake baffles on the front of the chassis below the fan assembly pushing the air over the internal components and out the exhaust on the top rear and sides of the chassis see Figure 1 6 Exhaust air Ambie...

Страница 6: ...Au g u s t 2 0 0 3 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Chassis 1 6 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Figure 1 5 Cisco ONS 15530 CHAS N Chassis 77081 F A N S T A T U S ...

Страница 7: ...oard see Figure 1 8 The controller board monitors the status of each fan and reports the status to the CPU switch modules If a single fan fails a minor alarm is reported to the CPU and the fan assembly LED changes from green to yellow see Figure 1 7 If two or more fans fail a major alarm is reported to the CPU and the fan LED changes to red Table 1 1 lists the fan assembly LED status describing th...

Страница 8: ...erview Cisco ONS 15530 Chassis 1 8 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Figure 1 7 Fan Assembly LED Fan assembly LED 77796 Table 1 1 Fan Assembly Status Fan Failure LED Status None Green Normal One Yellow Minor Two or more Red Major ...

Страница 9: ...5530 Chassis Figure 1 8 Fan Assembly Power Supplies The Cisco ONS 15530 chassis supports redundant 120 240 VAC see Figure 1 9 or 48 VDC see Figure 1 10 power The power supplies are located at the right of the chassis next to the card slots see Figure 1 1 Up to two power supplies can be installed for redundancy 77834 FAN STATUS ...

Страница 10: ...40 VAC Power Supply Figure 1 10 48 VDC Power Supply See the Powering Up the Shelf section on page 2 47 for more information about the power supplies 77894 FASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POWER SUPPLY 100 240V 8 0 3 5A 50 60 HZ GOOD FAIL 77893 FAIL 48 TO 60V 17 A GOOD FASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POWER SUPPLY ...

Страница 11: ...is mounted directly below the fan assembly It provides storage for the excess cable length Sliding radius limiters move to release the excess fiber cable slack when the drawer is pulled out allowing the user to raise the fiber routing tray and access the fan assembly Cisco ONS 15530 Components The following hardware components can be installed in the Cisco ONS 15530 CPU Switch Modules page 1 12 OS...

Страница 12: ...U switch module has a processor a switch fabric a clock an Ethernet switch for communication between processors and with the LRC line card redundancy controller on the OADM modules and line cards and an SRC switch card redundancy controller The active processor controls the system All LRCs in the system use the system clock and synchronization signals from the active processor Interfaces on the CP...

Страница 13: ... Overview Cisco ONS 15530 Components Figure 1 11 Cisco ONS 15530 CPU Switch Module STATU S R ESET AC TIVE STAN D BY C O M PAC T FLASH C IR TIC AL M AJO R AU X N M E FD X 100M BPS LIN K C O N C U TO FF H IST C LR C U TO FF H IST M IN O R 77664 15530 CPU A L A R M S 1 3 5 6 9 11 17 18 13 7 8 12 14 15 16 10 4 2 ...

Страница 14: ...lash card slot 14 Link LED 6 Minor alarm LED 15 100 Mbps LED 7 Major alarm LED 16 Full duplex LED 8 Critical alarm LED 17 Console port 9 Cutoff LED 18 Auxiliary port Table 1 2 CPU Switch Module LEDs LED Status Description STATUS Green IOS is loaded and running Yellow Card is in the process of booting ACTIVE Green Module is the primary CPU switch module otherwise the LED is off STANDBY Green Module...

Страница 15: ...ide major or minor alarm has occurred CUTOFF Red A major or minor alarm exists and the cutoff button has been pushed FDX Green Module is running full duplex Off Module is running half duplex 100MBPS Green Module is running at 100 Mbps Off Module is running at 10 Mbps LINK Green Link is up Off Link is down Table 1 2 CPU Switch Module LEDs continued LED Status Description ...

Страница 16: ... panel of the CPU switch module have an extra EMI shield and the signals going to them are filtered Table 1 3 shows the pinouts of the console and auxiliary ports CompactFlash Card Slot A CompactFlash card slot see Figure 1 11 can store the Cisco IOS image or a system configuration file on a CompactFlash memory card The system can also boot from the software stored on the CompactFlash memory card ...

Страница 17: ...t connection to each Cisco ONS 15530 in the network Up to two OSC modules can be installed in the carrier motherboard one module for the west direction and one for the east direction The OSC always terminates on a neighboring node By contrast data channels may or may not be terminated on a given node depending on whether the channels on the OADM modules are treated as either express pass through o...

Страница 18: ... PSM switches the received signal to the standby path Since the PSM occupies one of the OADM subslots in the shelf it protects a maximum of four channels and the OSC in a single shelf configuration The PSM also has an optical monitor port for testing the west and east receive signals This port samples one percent of these signals which can be monitored with an optical power meter or optical spectr...

Страница 19: ...Hardware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 13 PSM 85519 1 2 3 4 5 1 Rx Tx West ports 2 Rx Tx East ports 3 East West LEDs 4 East West Optical Monitor ports 5 Common In Out ports ...

Страница 20: ...ansponder line cards one for each wavelength supported by the OADM modules The Cisco ONS 15530 supports four types of single client interface transponder line cards SM single mode unprotected SM splitter protected MM multimode unprotected and MM splitter protected Both types of SM transponder line cards accept SM client signals on the 1310 nm wavelength through an SC connector and support client s...

Страница 21: ...isco ONS 15530 Hardware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 14 Transponder Line Card LEDs Nonsplitter STATU S 77659 T X T X T X R X R X R X T X R X 1 5 7 4 2 6 8 3 ...

Страница 22: ...ts 1 22 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Callout Description Callout Description 1 Card status LED 5 Client side transmit LED 2 ITU side port 6 Client side transmit port 3 ITU transmit LED 7 Client side receive LED 4 ITU receive LED 8 Client side receive port ...

Страница 23: ...e 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 15 Transponder Line Card LEDs Splitter STATU S 77660 T X T X T X E A S T W E S T R X T X R X R X R X T X R X 1 2 6 8 10 3 7 9 11 5 4 W ITU TX W ITU RX E ITU TX E ITU RX 1310 TX 1310 RX ...

Страница 24: ...r has a sensitivity of 32 dBm The ports on the trunk side use MU type connectors Transponder Line Card LEDs Table 1 6 lists the LEDs on the transponder line card faceplate their default conditions and what the conditions indicate Callout Description Callout Description 1 Card status LED 7 East side ITU port 2 West side ITU LED 8 Client side transmit LED 3 West side ITU port 9 Client side transmit ...

Страница 25: ...e OADM modules multiplex signals transmitted by the transponder line cards and 10G ITU trunk cards over optical cross connections and provide the interfaces to connect the multiplexed signal to the DWDM trunk side In the receive direction the OADM modules demultiplex the signals from the trunk side before passing them over optical cross connections to the transponder line cards and 10G ITU trunk c...

Страница 26: ...Variable Optical Attenuator and Per Band Optical Equalizer Modules The WB VOA wide band variable optical attenuator and PB OE per band power equalizer modules are half width modules that allow the ONS 15530 to extend the internodal and ring circumference distances and number of nodes supported for point to point hub ring and mesh ring networks by equalizing power levels 91400 1 ...

Страница 27: ...on the Cisco ONS 15530 chassis The carrier motherboard can be installed in slots 1 to 4 or 7 to 10 All optical connectors are located on the front panel and the connectors are angled Figure 1 17 and Figure 1 18 show the single and dual versions of the WB VOA module Figure 1 19 and Figure 1 20 show the single band and dual band versions of the PB OE module Figure 1 17 Single WB VOA Module 79166 2 3...

Страница 28: ...al WB VOA Module Table 1 7 Single WB VOA Module LEDs LED Status Description PM1 Green Light reception exists at the port STA Green Card is properly initialized 79168 PM1 PM2 STA 15500 VOA 0200 IN1 OUT1 IN2 OUT2 3 4 5 2 7 8 1 6 Callout Description Callout Description 1 PM2 LED 5 OUT1 port 2 PM1 LED 6 Handle 3 Card status LED 7 IN2 port 4 IN1 port 8 OUT2 port ...

Страница 29: ...ingle Band PB OE Module Table 1 8 Dual WB VOA Module LEDs LED Status Description PM2 Green Light reception exists at the port PM1 Green Light reception exists at the port STATUS Green Card is properly initialized 79173 4 6 7 1 3 5 2 Callout Description Callout Description 1 PM1 LED 5 OUT port 2 Card status LED 6 UPG IN port 3 IN port 7 UPG OUT port 4 Handle ...

Страница 30: ...nd PB OE Module Table 1 9 Single Band PB OE Module LED Status Description PM1 Green Light reception exists at the port STA Green Card is properly initialized Callout Description Callout Description 1 PM2 LED 5 Handle 2 PM1 LED 6 OUT port 3 Card status LED 7 UPG IN port 4 IN port 8 UPG OUT port 79006 5 7 8 1 2 4 6 3 PM2 PM1 STA 15500 PEQ 02EF IN OUT UPG IN UPG OUT ...

Страница 31: ...ection The ESCON aggregation card uses multi mode 62 5 125 um optical cable with SFPs small form factor pluggables and MT RJ connectors for the client signals See Figure 1 21 Note The SFPs part number 15500 XVRA 01A2 ONS 15530 ESCON 1310nm MM MTRJ must be purchased separately Note A patch cable to adapt MT RJ connectors to standard ESCON connectors directly or intermediately to SC type connectors ...

Страница 32: ...0 Components 1 32 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Figure 1 21 Cisco ONS 15530 ESCON Aggregation Card STATU S 77663 T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X 15530 LCMB 0200 0 1 2 3 4 5 6 7 8 9 1 T X R X 0 2 3 4 ...

Страница 33: ...s signals These aggregated signals pass through the backplane and the switch fabric on the active CPU switch module to a 2 5 Gbps ITU trunk card a 10 Gbps ITU trunk card or a 10 Gbps uplink card The cross connections between the two cards through the backplane and switch fabric are configured using the CLI The 8 port FC GE aggregation card has redundant connections over the backplane to the switch...

Страница 34: ...ingle mode SFP optic with a multimode SFP optic in the same port pair Table 1 12 lists features for the SFP optics supported by the 8 port FC GE aggregation card The Cisco ONS 15530 supports up to four 8 port FC GE aggregation cards for a total of 32 client signals Table 1 12 8 Port FC GE aggregation card SFP Optics Features Part Number Supported Protocols Fiber Type Wavelength Connector Type 1550...

Страница 35: ...tallation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 22 8 Port FC GE Aggregation Card 85440 STATU S T X R X T X R X T X R X T X R X T X R X T X R X T X R X T X R X 15530FCGE 8P 0 1 2 3 4 5 6 7 1 T X R X 0 2 3 4 ...

Страница 36: ...ne of two channel frequencies There are 16 different 2 5 Gbps ITU trunk cards for channels 1 2 3 4 31 32 to support the 32 channels The 2 5 Gbps ITU trunk card has two versions nonsplitter shown in Figure 1 24 and splitter shown in Figure 1 23 The nonsplitter version has only one pair of optical connectors on the front panel which connects to either the east or the west OADM module and can be used...

Страница 37: ...0 Hardware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 23 2 5 Gbps ITU Trunk Card Splitter 91504 T X R X T X R X T X W E S T E A S T E ITU TX E ITU RX W ITU TX W ITU RX R X S T A T U S ...

Страница 38: ...isco ONS 15530 Overview Cisco ONS 15530 Components 1 38 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 1 Card status LED 5 Receive LED 2 West side port LED 6 East side port LED 3 West side port 7 East side port 4 Transmit LED ...

Страница 39: ...530 Hardware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 24 2 5 Gbps ITU Trunk Card Nonsplitter 85315 T X R X T X R X T X E ITU TX E ITU RX W ITU TX W ITU RX R X S T A T U S 1 4 3 2 ...

Страница 40: ... has two versions nonsplitter and splitter The nonsplitter version has only one pair of optical connectors on the front panel which connects to either the east or the west OADM module and can be used for unprotected line card protected or switch fabric protected applications see Figure 1 25 The splitter version of the 10 Gbps ITU trunk card has two pairs of optical connectors on the front panel wh...

Страница 41: ...2 0 0 3 1 41 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 25 10 Gbps ITU Trunk Card Nonsplitter STATU S 77661 T X T X R X R X 1 2 4 3 ...

Страница 42: ...7 Au g u s t 2 0 0 3 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components 1 42 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 1 Card status LED 3 Transmit LED 2 ITU port 4 Receive LED ...

Страница 43: ...dware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components Figure 1 26 10 Gbps ITU Trunk Card Splitter STATU S 77662 T X T X E A S T W E S T R X T X R X R X 1 2 6 3 7 5 4 W ITU TX W ITU RX E ITU TX E ITU RX ...

Страница 44: ... to the backplane Each interface connects to the switch fabric on the active and standby CPU switch modules The 10 Gbps uplink card has only one version nonsplitter The nonsplitter version has only one pair of optical connectors on the front panel and can be used for unprotected or line card protected applications For splitter protected configurations the splitter line card motherboards on the Cis...

Страница 45: ...0 0 3 1 45 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components The Cisco ONS 15530 supports up to four 10 Gbps uplink cards for a total of four signals ...

Страница 46: ... 0 3 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components 1 46 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 Figure 1 27 10 Gbps Uplink Card T X R X T X R X STATU S 15530 10GE UPLINK 77665 1 2 3 4 5 ...

Страница 47: ... 15530 Overview Cisco ONS 15530 Components Table 1 16 describes the 10 Gbps uplink line card LED status Table 1 16 10 Gbps Uplink Line Card LEDs LED Status Description STATUS Green Card is properly initialized TX Green Port is up and transmit laser is enabled RX Green Light reception exists at the port ...

Страница 48: ...7 Au g u s t 2 0 0 3 Chapter 1 Cisco ONS 15530 Overview Cisco ONS 15530 Components 1 48 Cisco ONS 15530 Hardware Installation Guide 78 14228 02 ...