![Cisco ONS 15501 Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/cisco/ons-15501/ons-15501_user-manual_63583077.webp)
4-43
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
settempmean
settempmean
To modify the internal case temperature alarm mean level, use the settempmean command.
settempmean mean
Syntax Description
Defaults
30° C
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Usage Guidelines
The internal case temperature mean is measured in degrees Celcius. The system accepts a minimum
value of 10°C and a maximum value of 90°C. If a value entered falls outside of this acceptable range,
the command will be ignored and have no effect.
Examples
The following example shows how to modify the internal case temperature alarm mean level.
edfa > settempmean 29.00
Related Commands
mean
Specifies the desired internal case temperature alarm mean level.
Release
Modification
EDFA 1.0
This command was introduced.
Command
Description
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer’s default settings.
Sets the internal case temperature alarm trigger level.
Displays the internal case temperature level.
Displays the internal case temperature alarm mean level.
Displays the internal case temperature alarm trigger level.
Содержание ONS 15501
Страница 22: ...1 10 Cisco ONS 15501 User Guide 78 14134 01 Release 1 0 Chapter 1 Product Overview Cisco ONS 15501 Front Panel ...
Страница 92: ...4 58 Cisco ONS 15501 User Guide 78 14134 01 Release 1 0 Chapter 4 Command Reference timezone ...
Страница 96: ...5 4 Cisco ONS 15501 User Guide 78 14134 01 Release 1 0 Chapter 5 Troubleshooting Technical Support ...