NTP-L68 Upgrading to ONS 15454 M6 ECU60-S Module
Always use the supplied ESD wristband when working with a powered ONS 15454 M6. For detailed instructions
on how to wear the ESD wristband, see the
Electrostatic Discharge and Grounding Guide for Cisco CPT and
.
Caution
Do not replace the 15454-M6-DC20, or 15454-M6-DC40 power modules with the 15454-M6-DC V03 power
module if the ONS 15454 M6 shelf is consuming more than 960 W of power. Refer to table A-4 to ascertain
the power consumption of the shelf.
Note
Procedure
Step 1
Power down the ONS 15454 M6 shelf.
Step 2
Remove the 15454-M6-DC20 or 15454-M6-DC40 DC power module from the ONS 15454 M6 shelf.
Step 3
Install the 15454-M6-DC V03 DC Power Module in the ONS 15454 M6 shelf as described in the
Install the DC Power Module in the ONS 15454 M6 Shelf, on page 90
Step 4
Remove the ECU module (ECU/ECU-2/ECU-S) from the ONS 15454 M6 shelf.
Step 5
Install the ECU60-S module in the ONS 15454 M6 shelf as described in the
.
Step 6
Power on the 15454-M6-DC V03 power module as described in the
NTP-G256 Install Power and Ground to
the ONS 15454 M6 Shelf , on page 100
Stop. You have completed this procedure.
Power Modules
The ONS 15454 M6 system contains pluggable and redundant power modules for AC and DC power. The
AC and DC power modules cannot be used simultaneously to power the ONS 15454 M6 system. Before
installing the power module, verify the position of the mechanical locking system on the rear side of the
chassis. To insert the AC power module, the screw must be next to the AC silk-screen text; to insert the DC
power module the screw must be next to the DC silk-screen text.
AC Power Module
The ONS 15454 M6 system can be powered by a single AC power module or redundant AC power modules.
The supported AC power modules on the ONS 15454 M6 shelf are 15454-M6-AC and 15454-M6-AC2. The
AC power module converts the AC-input current to DC-output current.