None
Security Level
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do
not view directly with optical instruments. Viewing the laser output with certain optical instruments
(for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye
hazard.
Statement 1056
Warning
Procedure
Step 1
Using an inspection microscope, inspect each fiber connector for dirt, cracks, or scratches.
Step 2
Replace any damaged fiber connectors.
Replace all dust caps whenever the equipment is unused for 30 minutes or more.
Note
Step 3
Complete the
DLP-G262 Clean Fiber Connectors with CLETOP, on page 13
as necessary.
Step 4
Complete the
DLP-G263 Clean the Fiber Adapters, on page 13
as necessary.
To clean multi-fiber optic connectors, complete the
DLP-G261 Clean Multi Fiber-Optic Cable
as necessary.
Note
Stop. You have completed this procedure.
DLP-G261 Clean Multi Fiber-Optic Cable Connectors
This task cleans the multi fiber optic connectors
Purpose
Cleaning Cartridge for multi fiber optic connectors
Tools/Equipment
None
Prerequisite Procedures
Required
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams
or view directly with optical instruments.
Statement 1051
Warning
Procedure
Step 1
Remove the protective cap on the optical fiber cable connector.
Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
12
Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
DLP-G261 Clean Multi Fiber-Optic Cable Connectors