Chapter 14 Alarm Troubleshooting
Alarm Procedures
c.
Right-click to choose
RESET CARD
.
Step 5
If the alarm persists, physically reseat the reporting card.
Step 6
Clear the force switch:
a.
At the node view, click the
Maintenance
tab, then click the
Protection
tabs.
b.
Double-click the protection group that contains the reporting card.
c.
Highlight either selected group.
d.
Click
Clear
and click
YES
at the confirmation dialog box.
Step 7
If the reporting traffic card is protect, perform a software reset on the reporting card:
a.
Display the CTC node view.
b.
Position the cursor over the slot reporting the alarm.
c.
Right-click and choose
RESET CARD
.
Step 8
If the alarm persists, physically reseat the reporting card.
Step 9
If the alarm persists, replace the standby cross-connect card.
Note
When you replace a card with an identical type of card, you do not need to make any changes to
the database.
Step 10
If the alarm persists, replace the reporting traffic card.
14.4.32 CTNEQPT-PBWORK
•
Critical, Service-Affecting
The interconnection equipment failure protect payload bus (CTNEQPT-PBWORK) alarm indicates a
failure in the main payload bus between the active cross-connect XTC card and the reporting traffic card.
The cross-connect card and the reporting card are no longer communicating through the backplane. The
problem exists in the reporting traffic card or the backplane.
Caution
Always use the supplied ESD wristband when working with a powered ONS 15327. Plug the wristband
cable into the ESD jack located on the lower-right outside edge of the shelf assembly
Note
If all traffic cards show this alarm, do a forced side switch on the active XTC card, as shown in Step 1,
and physically reseat this XTC card. If this fails to clear the alarm, replace the XTC card. Do not
physically reseat an active XTC card; this disrupts traffic.
Procedure: Clear the CTNEQPT-PBWORK Alarm
Step 1
Do a side switch from the active cross-connect XTC card to the protect cross-connect card:
a.
Determine the active cross-connect card. The ACT/STBY LED of the active card is green. The
ACT/STBY LED of the standby card is yellow.
Содержание ONS 15327
Страница 22: ...Contents xxii Cisco ONS 15327 User Documentation June 2002 I N D E X ...
Страница 30: ...Figures xxviii Cisco ONS 15327 User Documentation June 2002 ...
Страница 44: ...Procedures xlii Cisco ONS 15454 Installation and Operations Guide R3 2 June 2002 ...
Страница 82: ...1 32 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 1 Hardware Installation Hardware Specifications ...
Страница 166: ...4 22 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 4 IP Networking ONS 15327 Routing Table ...
Страница 254: ...7 22 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 7 Card Provisioning Using Virtual Wires ...
Страница 408: ...13 26 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 13 Card Reference E10 100 4 Card ...
Страница 540: ...Glossary GL 16 Cisco ONS 15327 User Documentation R3 3 June 2002 ...