18-47
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 18 DLPs H200 to H299
Step 4
Click
Apply
.
Step 5
Return to your originating procedure (NTP).
Table 18-12
Optical Port SDH Thresholds Options
Parameter
Description
Port
Port number
•
1-1 (STM1, STM4, or STM16 for the ONS 15310-MA SDH)
•
2-1 (STM1, STM4, or STM16 for the OS 15310-MA SDH)
CV
Coding violations. Available for Line, Section, or Path (Near and Far End).
ES
Errored seconds. Available for Line, Section, or Path (Near and Far End).
FC
Failure count. Available for Line and Path (Near End or Far End).
SES
Severely errored seconds. Available for Line, Section, and Path (Near End and Far
End).
UAS
Unavailable seconds. Available for Line and Path (Near End and Far End).
PPJC-PDET
Positive Pointer Justification Count, VC high-order path Detected. Available for Line
(Near End and Far End).
NPJC-PDET
Negative Pointer Justification Count, VC high-order path Detected. Available for Line
(Near End and Far End).
PPJC-PGEN
Positive Pointer Justification Count, VC high-order path Generated. Available for Line
(Near End and Far End).
NPJC-PGEN
Negative Pointer Justification Count, VC high-order path Generated. Available for Line
(Near End and Far End).
PJCDIFF
Pointer Justification Count Difference is the absolute value of the difference between
the total number of detected pointer justification counts and the total number of
generated pointer justification counts. That is, PJCDiff is equal to (PPJC-PGEN -
NPJC-PGEN) – (PPJC-PDET – NPJC-PDET). Available for Path (Near End and Far
End).
PJCS-PDET
Pointer Justification Count Seconds, VC high-order path Detected (PJCS-PDET) is a
count of the one-second intervals containing one or more PPJC-PDET or NPJC-PDET.
Available for Path (Near End and Far End).
PJCS-PGEN
Pointer Justification Count Seconds, VC high-order path Generated (PJCS-PGEN) is a
count of the one-second intervals containing one or more PPJC-PGEN or NPJC-PGEN.
Available for Path (Near End and Far End).
PSC
Protection Switching Count (Line). Available for Line (Near End and Far End).
PSD
Protection Switching Duration (Line). Available for Line (Near End and Far End).
PSC-W
Protection Switching Count, Working Line. Available for Line (Near End and Far End).
PSD-W
Protection Switching Duration, Working Line. Available for Line (Near End and Far
End).
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...