![Cisco Nexus 9364C-GX Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/cisco/nexus-9364c-gx/nexus-9364c-gx_hardware-installation-manual_2609210053.webp)
Heat Dissipation
Requirement
Maximum Power
Consumption (AC or DC)
Typical Power
Consumption (AC or DC)
Switch
5534.494 BTUs per hour
1622 W
811 W
Cisco Nexus 9364C-GX
Power Specifications
Power specifications include the specifications for each type of power supply module.
2000-W AC Power Supply Specifications
Specification
Property
2000 W
Power
90 to 140 VAC
Input Voltage
50 to 60 Hz
Frequency
90% or greater (20 to 100% load)
Efficiency
Combined,
n
+1, and
n
+
n
Redundancy Modes
Yes
RoHS Compliance
Yes
Hot Swappable
Port-side intake and port-side exhaust airflow
Airflow Direction
2000-W HVAC/HVDC Power Supply Specifications
Specification
Property
2000 W
Power
180 to 305 VAC or
192 to 400 VDC or
Input Voltage
50 to 60 Hz
Frequency
90% or greater (20 to 100% load)
Efficiency
Combined,
n
+1, and
n
+
n
Redundancy Modes
Yes
RoHS Compliance
Yes
Hot Swappable
Port-side intake airflow
Airflow Direction
Cisco Nexus 9364C-GX ACI-Mode Switch Hardware Installation Guide
45
System Specifications
Power Specifications
Содержание Nexus 9364C-GX
Страница 6: ...Cisco Nexus 9364C GX ACI Mode Switch Hardware Installation Guide vi Contents ...
Страница 30: ...Cisco Nexus 9364C GX ACI Mode Switch Hardware Installation Guide 22 Installing the Chassis Starting the Switch ...
Страница 64: ...Cisco Nexus 9364C GX ACI Mode Switch Hardware Installation Guide 56 Additional Kits Additional Kits ...