Full Redundancy
Mode
Input Source
Redundancy
Mode
Power Supply
Redundancy
Mode
Combined Mode
Power Supplies
Power Inputs
—
—
—
3100 W
1
1 input (210 V)
3100 W
3100 W
3100 W
6200 W
2
3100 W
3100 W
6200 W
9300 W
3
6200 W
6200 W
9300 W
12,400 W
4
6200 W
6200 W
12,400 W
15,500 W
5
9300 W
9300 W
15,500 W
18,600 W
6
9300 W
9300 W
18,600 W
21,700 W
7
12,400 W
12,400 W
21,700 W
24,800 W
8
12,400 W
12,400 W
24,800 W
27,900 W
9
15,500 W
15,500 W
27,900 W
31,000 W
10
15,500 W
15,500 W
31,000 W
34,100 W
11
18,600 W
18,600 W
34,100 W
37,200 W
12
18,600 W
18,600 W
37,200 W
40,300 W
13
21,700 W
21,700 W
40,300 W
43,400 W
14
21,700 W
21,700 W
43,400 W
46,500 W
15
24,800 W
24,800 W
46,500 W
49,600 W
16
A combination of 3-kW DC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Overview of Fan Trays
The Cisco Nexus 7718 switch supports two types of fan trays:
•
38 mm Gen 1 Fan Tray (N77-C7718-FAN)
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
OL-30453-01
99
Managing the Switch
Overview of Fan Trays