Temperature:
--------------------------------------------------------------------
Module
Sensor
MajorThresh
MinorThres
CurTemp
Status
(Celsius)
(Celsius)
(Celsius)
--------------------------------------------------------------------
1
Crossbar1(s1)
125
115
51
Ok
1
Crossbar2(s2)
125
115
51
Ok
1
Arb-mux (s3)
125
115
35
Ok
1
L2L3Dev1(s5)
125
115
31
Ok
1
L2L3Dev2(s6)
125
115
29
Ok
1
L2L3Dev3(s7)
125
115
34
Ok
1
L2L3Dev4(s8)
125
115
32
Ok
1
L2L3Dev5(s9)
125
115
31
Ok
1
L2L3Dev6(s10)
125
115
32
Ok
2
Inlet
(s1)
60
42
17
Ok
2
Crossbar(s2)
125
115
58
Ok
2
L2L3Dev1(s3)
125
110
39
Ok
2
Arbiter (s4)
125
105
47
Ok
2
CPU1CORE1(s5)
85
75
27
Ok
2
CPU1CORE2(s6)
85
75
26
Ok
2
CPU1CORE3(s7)
85
75
26
Ok
2
CPU1CORE4(s8)
85
75
24
Ok
2
CPU2CORE1(s9)
85
75
23
Ok
2
CPU2CORE2(s10)
85
75
21
Ok
2
CPU2CORE3(s11)
85
75
24
Ok
2
CPU2CORE4(s12)
85
75
19
Ok
2
DDR3DIMM1(s13)
95
85
25
Ok
2
DDR3DIMM2(s14)
95
85
24
Ok
2
DDR3DIMM4(s16)
95
85
22
Ok
2
DDR3DIMM5(s17)
95
85
21
Ok
Displaying Temperatures for Modules
Each module has temperature sensors with two thresholds:
•
Minor temperature threshold
—
When a minor threshold is exceeded, a minor alarm occurs and the
following actions occur for all four sensors:
◦
Displays system messages
◦
Sends Call Home alerts (if configured)
◦
Sends SNMP notifications (if configured)
•
Major temperature threshold
—
When a major threshold is exceeded, a major alarm occurs and the
following actions occur:
◦
For sensors 1, 3, and 4 (outlet and onboard sensors), the following actions occur:
◦
Displays system messages.
◦
Sends Call Home alerts (if configured). For more information, refer
Group with a Destination Profile
.
◦
Sends SNMP notifications (if configured). For more information, refer
.
◦
For sensor 2 (intake sensor), the following actions occur:
Cisco Nexus 7702 Hardware Installation Guide
44
Managing the Switch
Displaying Temperatures for Modules