Verifying the Fabric Binding Configuration
To display fabric binding information, perform one of the following tasks:
Command
Displays the configured fabric binding database. You
can add the
active
keyword to display only the active
fabric binding database.
show fabric-binding database
[
active
]
Displays the configured fabric binding database for
the specified VSAN.
show fabric-binding database
[
active
] [
vsan
vsan-id
]
Displays statistics for the fabric binding database.
show fabric-binding statistics
Displays fabric binding status for all VSANs.
show fabric-binding status
Displays fabric binding violations.
show fabric-binding violations
Displays the configured fabric binding database for
the specified VSAN.
show fabric-binding efmd
[
vsan vsan-id
]
This example shows how to display the active fabric binding information for VSAN 4:
switch#
show fabric-binding database active vsan 4
This example shows how to display fabric binding violations:
switch#
show fabric-binding violations
-------------------------------------------------------------------------------
VSAN Switch WWN [domain]
Last-Time
[Repeat count] Reason
-------------------------------------------------------------------------------
2
20:00:00:05:30:00:4a:1e [0xeb] Nov 25 05:46:14 2003
[2]
Domain mismatch
3
20:00:00:05:30:00:4a:1e [*] Nov 25 05:44:58 2003
[2]
sWWN not found
4
20:00:00:05:30:00:4a:1e [*] Nov 25 05:46:25 2003
[1]
Database mismatch
In VSAN 3, the sWWN was not found in the list. In VSAN 2, the sWWN was found in the list, but has a
domain ID mismatch.
Note
This example shows how to display EFMD Statistics for VSAN 4:
switch#
show fabric-binding efmd statistics vsan 4
Default Settings for Fabric Binding
The following table lists the default settings for the fabric binding feature.
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x
OL-30895-01
273
Configuring Fabric Binding
Verifying the Fabric Binding Configuration