S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
1-5
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring SAN Port Channels
Configuring SAN Port Channels
Configuring SAN Port Channels
SAN port channels are created with default values. You can change the default configuration just as any
other physical interface.
provides examples of valid SAN port channel configurations.
Figure 1-5
Valid SAN Port Channel Configurations
shows examples of invalid configurations. Assuming that the links are brought up in the 1, 2,
3, 4 sequence, links 3 and 4 will be operationally down as the fabric is misconfigured.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Switch A
Switch B
Switch A
Switch B
Channel Group 10
Channel Group 20
Channel Group 10
Channel Group 20
Channel Group 1
Channel Group 2
187235