S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
1-13
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring Domain Parameters
Domain IDs
Displaying Pending Changes
You can display the pending configuration changes using the
show fcdomain pending
command.
switch#
show fcdomain pending vsan 10
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
You can display the differences between the pending configuration and the current configuration using
the
show fcdomain pending-diff
command.
switch#
show
fcdomain pending-diff vsan 10
Current Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 24,100.
[User] configured allowed domain IDs: 1-239.
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
Displaying Session Status
You can display the status of the distribution session using the
show fcdomain session-status vsan
command.
switch#
show fcdomain session-status vsan 1
Last Action: Distribution Enable
Result: Success
About Contiguous Domain ID Assignments
By default, the contiguous domain assignment is disabled. When a subordinate switch requests the
principal switch for two or more domains and the domains are not contiguous, the following situations
can occur:
•
If the contiguous domain assignment is enabled in the principal switch, the principal switch locates
contiguous domains and assigns them to the subordinate switches. If contiguous domains are not
available, the switch software rejects this request.
•
If the contiguous domain assignment is disabled in the principal switch, the principal switch assigns
the available domains to the subordinate switch.