OIR Time
Temperature º C at 1800 m
Serial Number
30 seconds
31º C to 40º C
2
RSP Installation
Follow the steps in the sections below on handling an RSP module in the Cisco NCS 4216:
Installing an RSP Module
To install an RSP module in the router chassis, perform the following steps:
Procedure
Step 1
Choose a slot for the module. Make sure that there is enough clearance to accommodate any equipment that
will be connected to the ports on the module. If a blank module filler plate is installed in the slot in which you
plan to install the module, remove the plate by removing its 2 Phillips pan-head screws.
Step 2
Fully open both the ejector levers on the new module, as shown in the figure below.
To prevent ESD damage, handle modules by carrier edges only.
Caution
Step 3
Position the module in the slot. Make sure that you align the sides of the module with the guides on each side
of the slot, as shown in the figure below.
Installing the Cisco NCS 4216
26
Installing the Cisco NCS 4216
RSP Installation