Clear the OTDR-BASELINE-R-EXCEEDED-TX Alarm
The alarm is cleared automatically when one of the following conditions is satisfied:
• The reflectance event causing the alarm disappears.
• The reflectance event is below the threshold.
• The absolute threshold check is activated.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
OTDR-FAST-FAR-END-IN-PROGRESS
Default Severity: Minor (MN)
Logical Object: EQUIPMENT
The OTDR-FAST-FAR-END-IN-PROGRESS alarm is raised when a fast scan is started on the remote side.
Clear the OTDR-FAST-FAR-END-IN-PROGRESS Alarm
Step 1
Wait until the scan on the remote side is completed. The time varies depending on the type of scan.
Step 2
Alternatively, stop the scan by navigating to:
Maintenance
->
DWDM
->
OTDR
; select the side where the scan is ongoing
and click
Cancel
. The scan is stopped on both the sides.
If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
OTDR-FAST-SCAN-IN-PROGRESS-RX
Default Severities: Minor (MI), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Optical Time Domain Reflectometer (OTDR) Fast Scan In Progress Rx alarm is raised when the fast
OTDR scan starts in the Rx direction.
Clear the OTDR-FAST-SCAN-IN-PROGRESS-RX Alarm
Step 1
This alarm is cleared automatically when the fast OTDR scan in the RX direction is complete.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
332
Alarm Troubleshooting
Clear the OTDR-BASELINE-R-EXCEEDED-TX Alarm