Indentifier Mismatch
What to do next
1.
If the transmit or expected string was changed, restore the original string.
2.
Use a loopback. For more information, see
Troubleshooting the Trunk Port
Step 1
show controller coherentDSP R/S/I/P
Displays details of the coherent DSP controller.
Example:
RP/0/RP0/CPU0:ios#
show controller coherentDSP 0/0/0/6
Tue Nov 17 22:57:20.724 UTC
Port
: CoherentDSP 0/0/0/6
Controller State
:
Down
Secondary State
: Normal
Derived State
: In Service
Loopback mode
: None
BER Thresholds
: SF = 1.0E-5
SD = 1.0E-7
Performance Monitoring
: Enable
Alarm Information:
LOS = 2 LOF = 1 LOM = 2
OOF = 0 OOM = 0 AIS = 0
IAE = 0 BIAE = 0
SF_BER = 0
SD_BER = 0
BDI = 0 TIM = 0
FECMISMATCH = 0 FEC-UNC = 0
Detected Alarms
:
LOS
OTU TTI Sent
OPERATOR SPECIFIC
ASCII
:
:
OPERATOR SPECIFIC HEX
: 00000000000000000000000000000000
: 00000000000000000000000000000000
OTU TTI Expected
OPERATOR SPECIFIC
ASCII
:
:
OPERATOR SPECIFIC HEX
: 00000000000000000000000000000000
: 00000000000000000000000000000000
FEC mode
: Soft-Decision 7
Network SRLG values
: Not Configured
In the above output, you can verify the state of the controller and also verify the alarms related to the trunk port.