Some power supplies have capabilities that are greater than the maximum power requirements for a switch.
To determine the power consumption characteristics for the switch, use the typical and maximum requirements
that are listed in the following table.
Note
Heat Dissipation
Requirement
Maximum Power
Consumption (AC or DC)
Typical Power
Consumption (AC or DC)
Switch
2453.330 BTUs per hour
719 W
337 W
Cisco Nexus
9336C-FX2-E
Power Specifications
Power specifications include the specifications for each type of power supply module.
750-W AC Power Supply Specifications
These specifications apply to the following power supplies:
• NXA-PAC-750W-PE
• NXA-PAC-750W-PI
Specification
Characteristic
750 W
Maximum output power
10 Amps at 100 VAC
Maximum input current
115 to 240 VAC nominal (Range: 90 to 264 VAC)
Rated input voltage
50 to 60 Hz nominal (Range: 47 to 63 Hz)
Rated input frequency
1100-W AC Power Supply Specifications
These specifications apply to the following power supplies:
• NXA-PAC-1100W-PE and PE2
• NXA-PAC-1100W-PI and PI2
Specification
Characteristic
Nominal range: 100 and 240 VAC (Range: 90-132
VAC, 180-264 VAC)
AC input voltage
Nominal range: 50 to 60 Hz (Range: 47-63 Hz)
AC input frequency
Cisco Nexus 9336C-FX2-E NX-OS Mode Switch Hardware Installation Guide
33
System Specifications
Power Specifications
Содержание N9K-C9336C-FX2-E
Страница 8: ...Cisco Nexus 9336C FX2 E NX OS Mode Switch Hardware Installation Guide 4 Overview Overview ...
Страница 43: ...A P P E N D I X D Additional Kits Cisco Nexus 9336C FX2 E NX OS Mode Switch Hardware Installation Guide 39 ...
Страница 44: ...Cisco Nexus 9336C FX2 E NX OS Mode Switch Hardware Installation Guide 40 Additional Kits Additional Kits ...